• Title/Summary/Keyword: Iliac screw

Search Result 21, Processing Time 0.027 seconds

Full mouth implant rehabilitation of a patient with ectodermal dysplasia after orthognathic surgery, sinus and ridge augmentation: a clinical report

  • Bayat, Mohammad;Khobyari, Mohammad Mohsen;Dalband, Mohsen;Momen-Heravi, Fatemeh
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.96-100
    • /
    • 2011
  • An 18-year-old male presented severe hypodontia due to hypohidrotic ectodermal dysplasia was treated with Le Fort I maxillary osteotomy with simultaneous sinus floor augmentation using the mixture of cortical autogenous bone graft harvested from iliac crest and organic Bio-Oss to position the maxilla in a right occlusal plane with respect to the mandible, and to construct adequate bone volume at posterior maxilla allowing proper implant placement. Due to the poor bone quality at other sites, ridge augmentation with onlay graft was done to construct adequate bone volume allowing proper implant placement, using tissue harvested from the iliac bone. Seven implants were placed in the maxilla and 7 implants were inserted in the mandible and screw-retained metal ceramic FPDs were fabricated. The two year follow up data showed that dental implants should be considered as a good treatment modality for patients with ectodermal dysplasia.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.

Surgical Results of Patients with Isthmic Spondylolisthesis with Transpedicular Screw Fixation and Posterior Lumbar Interbody Fusion Using Posterior Movable Segment (협부형 척추전방전위증에 대한 후방가동관절 이용한 골유합술 및 척추경나사못 고정술의 수술적 결과)

  • Kim, Chan;Lee, Seung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.108-114
    • /
    • 2001
  • Objective : Posterior lumbar interbody fusion(PLIF) provides the favorable outcome to degenerative lumbar disease, especially isthmic spondylolisthesis. To determine the long-term effect of PLIF using psterior movable segment, we analysed the results of follow-up radiologic changes and surgical outcome retrospectively Patients and Method : During the past 11 years(1989. 1.-1999. 9.), 148 patients with symptomatic lumbar spondylolisthesis were managed at our department and the clinical wants were throughly recieved and final outcome is determined at last follow up. PLIF using antogenous bone(posterior movable segment, iliac bone and rib) were performed in 106 case. Results : After an average follow-up period of 33 months(range ; 15-58 months), the results were excellent in 66 cases, good in 37 cases, fair in 2 cases and poor in 1 cases. And the satisfactory results were 103 cases(98.2%) in PLIF,. Conclusion : In conclusion, patients who underwent PLIF with autologous bone graft had good clinical and radiological outcomes without significant neurological complications.

  • PDF

Posterior Cervical Fixation with Nitinol Shape Memory Loop in the Anterior-Posterior Combined Approach for the Patients with Three Column Injury of the Cervical Spine: Preliminary Report

  • Yu, Dong-Kun;Heo, Dong-Hwa;Cho, Sung-Min;Choi, Jong-Hun;Sheen, Seung-Hun;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.5
    • /
    • pp.303-307
    • /
    • 2008
  • Objective: The authors reviewed clinical and radiological outcomes in patients with three column injury of the cervical spine who had undergone posterior cervical fixation using Nitinol shape memory alloy loop in the anterior-posterior combined approach. Materials: Nine patients were surgically treated with anterior cervical fusion using an iliac bone graft and dynamic plate-screw system, and the posterior cervical fixation using Nitinol shape memory loop ($Davydov^{TM}$) at the same time. A retrospective review was performed. Clinical outcomes were assessed using the Frankel grading method. We reviewed the radiological parameters such as bony fusion rate, height of iliac bone graft strut, graft subsidence, cervical lordotic angle, and instrument related complication. Results: Single-level fusion was performed in five patients, and two-level fusion in four. Solid bone fusion was presented in all cases after surgery. The mean height of graft strut was significantly decreased from $20.46{\pm}9.97mm$ at immediate postoperative state to $18.87{\pm}8.60mm$ at the final follow-up period (p<0.05). The mean cervical lordotic angle decreased from $13.83{\pm}11.84^{\circ}$ to $11.37{\pm}6.03^{\circ}$ at the immediate postoperative state but then, increased to $24.39{\pm}9.83^{\circ}$ at the final follow-up period (p<0.05). There were no instrument related complications. Conclusion: We suggest that the posterior cervical fixation using Nitinol shape memory alloy loop may be a simple and useful method, and be one of treatment options in anterior-posterior combined approach for the patients with the three column injury of the cervical spine.

IMMEDIATE RECONSTRUCTION WITH A.C.P AND ILIAC BONE GRAFT AFTER PARTIAL MANDIBULECTOMY ON RECURRENT AMELOBLASTOMA. (재발된 법랑아세포종 환자에서 하악골 부분절제술후 금속판과 자가장골을 이용한 즉시재건술에 대한 증례보고)

  • Moon, Haeng-Gyu;Yeo, Hwan-Ho;Kill, Beug-Dong;Kim, Woon-Gyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.2
    • /
    • pp.53-59
    • /
    • 1989
  • The ameloblastoma is the most common form of the odontogenic tumors exhibiting minimal inductive change in connective tissue, it comprising 1% of all tumor and cysts of the jaws. It is a true neoplasm, generally considered to be a benign but persistent or, locally malignant lesion. The tumor occurs most commonly in persons between the age of 20 and 50 years. 80% and 90% of all lesions are in the mandible. The presenting clinical signs and symptoms of the ameloblastoma very from patient to patient, but most common symptom was swelling, followed by pain, draining sinuses, and superficial ulcerations. It is slow-growing lesion, and the radiographic features of the ameloblastoma depend large one the nature and the local bone reaction to the particular tumor. Recurrence rate is about 33%, but this is probably due to incommplete initial removal of lesion. We had operated a patient ; 29-year-old female immediate reconstruction combined with autocompression plate and iliac bone graft and screw fixation after hemimandibulaectomy with recurred ameloblastoma involving from premolar to ascending ramus at right side mandible. We obtained favorable results of good function, short intermaxillary fixation periods and easy operation precedure than the other reconstruction methods.

  • PDF

Subsidence Ratio after Anterior Cervical Interbody Fusion Using an Intraoperative Custom-made Cervical Cage

  • Kim, Dok-Ryong;Moon, Byung-Gwan;Kim, Jae-Hoon;Kang, Hee-In;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.301-305
    • /
    • 2007
  • Objective : The postoperative subsidence of anterior cervical interbody fusion for cervical degenerative diseases gives rise to segmental kyphotic collapse, screw loosening, and chronic neck pain. So, intraoperative custom-made polymethylmethacrylate [PMMA] C-cage has been developed to prevent subsidence following anterior cervical fusion. Methods : A total of patients who underwent anterior cervical interbody fusion with a intraoperative custom - made cervical cage filled with local bone and demineralized bone matrix [group A] were analyzed prospectively from June 2004 to June 2005. These were compared with 40 patients who were treated with iliac bone graft [group B]. We evaluated subsidence ratio, change of segmental angle, distraction length and segmental angle. Statistical analysis was performed using independent sample t-test and Pearson correlation coefficient. Results : Group A had a statistically significant decrease in subsidence ratio [$0.64{\pm}0.43%$, p=0.00]. distraction length [$2.42{\pm}1.25\;mm$, p=0.02], and follow angle change [$1.78{\pm}1.69^{\circ}$, p=0.01] as compared with Group B. However, there was no statistically significant difference in postoperative segmental angle change [p=0.66]. On the analysis of the correlation coefficient, the parameters showed no interrelationships in the group A. On the other hand, subsidence ratio was affected by distraction length in the group B [Pearson correlation=0.448]. Conclusion : This operative technique would be contributed for the reduction of a postoperative subsidence after the anterior cervical interbody fusion procedure for cervical disc disease with moderate to severe osteoporotic condition and segmental loss of lordosis.

Autogenous Low Heat Treated Bone Graft for Bone Reconstruction in Bone and Soft Tissue Tumors (골연부 종양에서 저온 열처리한 자가골을 이용한 재건술)

  • Jeon, Dae-Geun;Lee, Jong-Seok;Kim, Sug-Jun;Cho, Wan-Hyeong;Kwag, Bong-Jun;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.4 no.2
    • /
    • pp.81-87
    • /
    • 1998
  • Although autoclaved autogenous bone reconstruction is one of the established procedures, it may have some problems in bone regeneration and mechanical property. The purpose of this study is to evaluate the efficacy of more biologic and anatomical reconstruction where allograft is not readily available. From Aug.1991 to Feb. 1996 the authors analyzed 32 cases of reconstruction with autogenous low heat treated bone. Autogenous graft sites were humerus 4, tibia 4, pelvis 9, and 15 femur. Average follow-up period was 23(range;12-51) months. There were 49 graft-host junctional sites. Diaphysis was 22, metaphysis 10, and flat bone 17. Average duration of healing for the 38 united sites was 7 months. Average union time for each anatomical area 8 months in 19 diaphysis, 12 months in 7 metaphysis, and 12.7 months in 12 flat bone(pelvis). Eleven nonunion sites consisted of 3 diaphysis(3/22), 3 metaphysis(3/10), and 5 flat bone(5/17). Complications other than nonunion were local recurrence(4), bone resorption(3), graft fracture(2), osteomyelitis(1), metal failure(2), and wound infection(1). Initial bone quality and stable fixation technique was important for union rate. Plate and screw is a good method for diaphyseal lesion. Metaphyseal and flat bone are weak area for rigid fixation and one stage augmentation with iliac bone graft can be a salvage procedure.

  • PDF

The Safety and Efficacy of Cadaveric Allografts and Titanium Cage as a Fusion Substitutes in Pyogenic Osteomyelitis

  • Kim, Hyun-Woo;Ryu, Je-Il;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.348-356
    • /
    • 2011
  • Objective : The safety and efficacy of various fusion substitutes in pyogenic osteomyelitis has not been investigated. We evaluated and compared the cadaveric allograft and titanium cages used to reconstruct, maintain alignment and achieve fusion in the management of pyogenic spinal infection. Methods : There were 33 patients with pyogenic osteomyelitis underwent fusion in this study. Fifteen of the 33 patients were operated on by fusion with allografts (cadaveric patella bones) and 18 of those were operated with titanium mesh cages filled with autologous cancellous iliac bone. After the affected disc and vertebral body resection with pus drainage, cadaveric allograft or titanium cages were inserted into the resected space. Posterior transpedicular screw fixation and rod compression in resected space, where cadaveric allograft or titanium cages were inserted, was performed to prevent the malposition in all patients except in 1 case. Recurrent infection was identified by serial erythrocyte sedimentation rate and cross reactive protein follow-up. Osseous union and recurred infection available at a minimum of 2 years following operation was identified. The amount of kyphosis correction and the subsidence were measured radiographically. Results : Spinal fusion was achieved in 29 of 33 patients. In the cadaveric allograft group, 93.3% of patient (14 of 15) showed the osseous union while 83.3% of patient (15 of 18) in the titanium cage group showed union. Subsidence was noted in 12 of the patients. Twelve patients (36.3%) showed unsettling amounts of subsidence postoperatively whereas 46.6% of patients in the cadaveric allograft group and 37.7% of patients in the titanium cage group showed similar subsidence, respectively. There were statistical difference in the fusion rate (p=0.397) and subsidence rate (p=0.276) between the two groups. There was significant statistical difference in the postoperative improvement of segmental kyphosis between the two groups (p=0.022), that is the improvement in sagittal alignment was greater in the titanium cage group than in the cadaveric allograft group. There was no case of recurred infection. Conclusion : The cadaveric allograft and titanium cages are effective and safe in restoring and maintaining sagittal plane alignment without increased incidence in infection recurrence in pyogenic osteomyelitis. The postoperative improvement of segmental kyphosis was better in the cage group.

Compression Plate Fixation with Autogenous Bone Graft for Humerus Shaft Nonunion (상완골 간부 불유합에 대한 금속판 고정 및 자가골 이식술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Bae, Ki-Cheor;Kim, In-Kyoo;Kwon, Doo-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To evaluate the results of the compression plate fixation and autogenous bone graft in the management of humerus shaft nonunion. Materials and Methods: Eighteen cases were treated for humerus shaft nonunion using compression plate fixation and an autogenous iliac bone graft. The mean follow-up period was 28 months. Bony union was confirmed from the serial radiographs and the clinical outcomes were assessed according to ASES scoring system. Results: In 12 cases of initial plate fixation, the causes of nonunion were 6 cases of inadequate plate length, 2 with a broken plate, 2 with screw loosening, 1 infection and 1 noncompliance of a psychiatric patient. In 3 cases of initial intramedullary fixation, the cause of nonunion was a distraction of the fracture site. In 3 cases of external fixation, the cause of nonunion was inadequate fixation. All cases showed bony union after an average of 24 weeks. The clinical outcomes were 11 excellent, 6 good and 1 fair. Conclusion: In the treatment for nonunion, compression plate fixation with autogeneous bone graft after complete removal of the fibrous and necrotic tissue is believed to give satisfactory results.