• Title/Summary/Keyword: Iliac autograft

Search Result 8, Processing Time 0.026 seconds

Polyetheretherketone Cage with Demineralized Bone Matrix Can Replace Iliac Crest Autografts for Anterior Cervical Discectomy and Fusion in Subaxial Cervical Spine Injuries

  • Kim, Soo-Han;Lee, Jung-Kil;Jang, Jae-Won;Park, Hyun-Woong;Hur, Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.211-219
    • /
    • 2017
  • Objective : This study aimed to compare the clinical and radiologic outcomes of patients with subaxial cervical injury who underwent anterior cervical discectomy and fusion (ACDF) with autologous iliac bone graft or polyetheretherketone (PEEK) cages using demineralized bone matrix (DBM). Methods : From January 2005 to December 2010, 70 patients who underwent one-level ACDF with plate fixation for post-traumatic subaxial cervical spinal injury in a single institution were retrospectively investigated. Autologous iliac crest grafts were used in 33 patients (Group I), whereas 37 patients underwent ACDF using a PEEK cage filled with DBM (Group II). Plain radiographs were used to assess bone fusion, interbody height (IBH), segmental angle (SA), overall cervical sagittal alignment (CSA, C2-7 angle), and development of adjacent segmental degeneration (ASD). Clinical outcome was assessed using a visual analog scale (VAS) for pain and Frankel grade. Results : The mean follow-up duration for patients in Group I and Group II was 28.9 and 25.4 months, respectively. All patients from both groups achieved solid fusion during the follow-up period. The IBH and SA of the fused segment and CSA in Group II were better maintained during the follow-up period. Nine patients in Group I and two patients in Group II developed radiologic ASD. There were no statistically significant differences in the VAS score and Frankel grade between the groups. Conclusion : This study showed that PEEK cage filled with DBM, and plate fixation is at least as safe and effective as ACDF using autograft, with good maintenance of cervical alignment. With advantages such as no donor site morbidity and no graft-related complications, PEEK cage filled with DBM, and plate fixation provide a promising surgical option for treating traumatic subaxial cervical spine injuries.

One Stage Metatarsal Lengthening of Brachymetatarsia Involving Both 1st and 4th Metatarsal Bone (A case report) (양측 제 1,4 단중족증의 자가골을 이용한 일단계 골연장술(1예 보고))

  • Kim, Dong-Hee;Chung, Duke-Whan;Han, Chung-Soo;Lee, Jae-Hoon;Park, Jae-Yong;Oh, Kyung-Il;Tak, Dae-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.182-185
    • /
    • 2010
  • 19 years old girl presented with bilateral 1, 4th brachymetatarsia. We have used an autograft interposition technique to lengthen the brachymetatarsia involving first and fourth metatarsal. The technique was to graft the bone fragment from the relatively long second and third metatarsal bone to be used as an autograft to the short first and fourth metatarsal bone. The method is superior in not having the necessity of a long term external fixator which is needed using callotasis method and in also avoiding the inconvenience of performing an allograft. Absence of donor site complication during autograft from iliac bone is also an advantage to be mentioned. Our technique can therefore be ascertained as a successful method in both cosmetic results and improvement of symptoms including reduction in length of recovery.

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.

Triple Pelvic Osteotomy and Autograft to the Gap of Ischium for the Treatment of Pelvic Canal Narrowing in a Cat

  • Park, Ji-Hun;Kim, Keun-Yung;Lee, Chae-Yeong;Lee, Si-Eun;Park, Hyojin;Hwang, Tae-Sung;Lee, Hee-Chun;Lee, Dongbin;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.38 no.5
    • /
    • pp.235-239
    • /
    • 2021
  • Pelvic canal narrowing secondary to pelvic fractures can lead to episodes of recurrent constipation in cats. Triple pelvic osteotomy is considered as a surgical treatment method; however, there is potential for future recurrence of pelvic canal narrowing. This report describes a surgical method using a pelvic symphyseal autograft to keep the distraction of the ischial osteotomy gap to prevent the recurrence of pelvic canal narrowing. A triple pelvic osteotomy was planned to expand the narrow pelvic canal. The cranial ramus of the pubis was cut, and ischiatic and iliac osteotomies were performed. After expanding the ilium, the malunion pelvic symphysis was cut approximately 1 cm and then autografted to the gap of the ischiatic osteotomy line to keep the distraction. The patient showed clinical improvement postoperatively without recurrent pelvic canal narrowing related to triple pelvic osteotomy. However, constipation recurred on post-operative month-5. It was managed conservatively, and subtotal colectomy was performed eventually nine months post-operatively. There were no complications for five months of follow-up.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.

Anterior Cervical Discectomy and Fusion Using a Double Cylindrical Cage versus an Anterior Cervical Plating System with Iliac Crest Autografts for the Treatment of Cervical Degenerative Disc Disease

  • Kim, Seong Joon;Kim, Sang Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • Objective : Anterior cervical discectomy and fusion (ACDF) is often complicated by subsidence, pseudoarthrosis, kyphosis, and graft donor site morbidities. To decrease the occurrence of these complications, various types of cages have been developed. We designed this retrospective study to analyze and compare the efficacy and outcomes of ACDF using double cylindrical cages (DCC) (BK Medical, Seoul, Korea) versus an anterior cervical plating system with autogenous iliac crest grafts. Methods : Forty-eight patients were treated with autograft and plating (plate group), and 48 with DCC group from October 2007 to October 2011. We analyzed construct length, cervical lordotic curvarture, the thickness of the prevertebral soft tissue, segmental instability, and clinical outcomes. Results : There were no significant differences between the two groups with regard to the decrease in construct length or cervical lodortic curvature at the 3-, 6-, and 12-month follow-ups. The prevertebral soft tissue was thinner in the DCC group than the plate group immediately after surgery and at the 3-, 6-, and 12-month follow-ups. The difference in interspinous distance on flexion-extension was shorter in the plate group than the DCC group at the 3- and 6-month follow-ups. However, there was no significant difference in this distance between the two groups at the 12-month follow-up. Conclusion : A double cylindrical cage is a good alternative for fusion in patients with cervical degenerative diseases; the surgical method is relatively simple, allows good synostosis, has less associated prevertebral soft tissue swelling, and complications associated with autografting can be avoided.

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.

Assessment of the permanent canine bone support after secondary bone graft In UCLP patients (편측성 순구개열 환자에서 이차 골이식후 맹출된 영구 견치의 치조골 지지도에 관한 연구)

  • Park, Ki-Tae
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.601-610
    • /
    • 2001
  • The purpose of this retrospective study was to evaluate the level oi alveolar bone support of the erupted Permanent canine through the reconstructed cleft region compared to the contralateral canine on the non-cleft side. This study was limited to children with complete unilateral cleft lip and palate who underwent secondary alveolar iliac bone gvaft and the apices of the erupted canine roots were closed at the time of evaluation. With these criteria the study included 21 children whose average age at the time of bone graft reconstruction was 9.8 years, with a minimum of 12.4 years of age at the time of the evaluation. The study was limited to the use of iliac cancellous bone as the autograft material for reconstruction of the alveolar cleft. Cranial bone graft and other autogenous bone sources were excluded. The periapical radiographs were used to evaluate alveolar bone level of each canine. The percentages of root supported by the bone were established by dividing the amount of root covered with the bone by the anatomic root length. The canine oi the non-cleft side was used as an internal control and the canine on the cleft side was used as an experimental. There was a statistically significant difference in the alveolar bone support ratio between the control ($92.9\%$) and experimental canines ($8.7\%$). An average of $95\%$ level of alveolar bone support was achieved for the experimental canine in comparison to the control canine. Neither the presence of lateral incisor, nor the stage of root development of the canine at the time of the bone graft appeared to have affected the alveolar bone support ratio of the canine after the secondary bone graft.

  • PDF