• Title/Summary/Keyword: Ignition voltage

Search Result 150, Processing Time 0.02 seconds

Temperature Dependence on the Partial Discharge of Epoxy Molding Ignition Coil According to Applied Voltage (에폭시 성형 점화코일의 인가전압에 따른 부분 방전 온도 의존성)

  • Shin, Jong-Yeol;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • A gasoline engine automobile uses high voltage generation of the ignition coil, igniting and burning mixed fuel in the combustion chamber, which drives the engine. When the electronic control unit intermits a current supplied to the power transistor, counter electromotive force with a low voltage is generated by self induction action in the ignition primary coil and a high voltage is induced by mutual induction action with the primary ignition coil in the second ignition coil. The high voltage is supplied to the ignition plug in the combustion chamber, causing a spark, igniting the compressed mixed fuel. If a very small defect occurs inside the insulating material when a voltage is applied in said ignition coil, the performance of the insulation material will get worse and breakdown by a partial discharge of corona discharge. Thus, in this experiment, we are to contribute to improve the performance and ensure the reliability of the ignition coil by investigating partial discharge characteristics according to the change of voltage and temperature when a voltage is applied to the specimen of the epoxy molding ignition coil.

External Resonant Ignitior for HID Lamps by Using the Transformer (변압기를 이용한 외장형 HID 램프용 공진형 이그니터)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.9-16
    • /
    • 2014
  • The electronic ballast for HID lamps needs high ignition voltage which is consisted of high voltage pulse ignitor. However, In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. However, the resonant circuit which is consisted of LC occurs over current, so the capacity of the ignitor increases. The capacity of the ignitor can be reduced by using the transformer. In this case, the capacitor for resonance is installed to the secondary of the transformer, and the capacitor needs high withstanding voltage. Therefore, it needs to do the research on a resonant ignition to reduce the voltage over the resonant capacitor by dividing the secondary of the transformer.

Hazard Evaluation of Minimum Ignition Energy by Electrostatic Voltage in Suspended Dust Particles (부유 분진의 정전압에 의한 최소착화에너지 위험성평가)

  • Han, Oue-Sup
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.359-365
    • /
    • 2021
  • We investigated experimentally the ignition characteristic of dust and the hazard evaluating for electrostatic discharge. The ignition energy experiments were performed on sample dusts such as PE(HD), PE(LD), PMMA using the MIKE-3 apparatus. The formation of flame during the ignition of PE(HD) dust clouds occurred after the delay time of about 8 ms, and the flame kernels were not observed in center of ignition occurrence area. The voltage increased with increasing the number of dust dispersions and the increase rate of measured voltage with dust concentration was the highest in the order of PMMA, PE(LD) and PE(HD). For the effect of dispersion condition on the voltage in PE(HD) dust, the results were obtained that the voltage increased as the number of dispersions increased and as the concentration increased under the same dispersion number. The safety voltages to prevent fire and explosions by electrostatic ignition were estimated that PE(HD), PE(LD)-1, PE(LD)-2, and PMMA were 2.58, 44.72, 25.82, and 8.16 kV, respectively. We proposed the method for estimating the minimum ignition energy by using the measured voltage data for efficient investigation of electrostatic ignition hazard.

The Ballast for HID Lamps of Preventing the Overvoltage with a Long Distance Resonant Ignition (원거리 공진 기동시 과전압 방지 HID 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.94-102
    • /
    • 2015
  • The electronic ballast for HID lamps needs to ignite lamps even though the length from the ballast to lamp is far away. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps because the reduction of ignition voltage is not much depending on the distance. However, the parasitic capacitance is increased depending the length of the cable, and it affects the resonant frequency. The ignitor voltage can be increased drastically under the resonant ignition through frequency sweep, and it is the main reason of blowing up. Therefore, the clamping diode is proposed to suppress the voltage of the primary winding during resonant ignition.

Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker (진공차단기 3상 동시 차단시의 서지 특성 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF

Measurement Technique of Required Spark Voltage Using Primary Ignition Voltage and Misfire Application in a SI Engine (SI엔진에서 점화 1차 전압을 이용한 방전요구전압의 측정기법과 실화적용에 관한 연구)

  • 박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.10-19
    • /
    • 1999
  • In this study , a simple method has been developed to detect the required spark voltage by using the primary spark voltage instead of the secondary spark voltage. Through engine motoring experiments, this method testified to be quite satisfactory. Though the required spark voltage is affected by many in-cylinder conditions, temperature is one of the most important factors. The temperature increases significantly by combustion and the required spark voltage also changes by the temperature during the expansion stroke. On the basis of this fact, misfire can be monitored by comparing the required spark voltage between compression stroke and expansion stroke. So, in this study, two step ignition method is introduced to monitor combustion at expansion stroke. The test result shows that this method can be used to detect complex misfire pattern.

  • PDF

Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torches

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.591-598
    • /
    • 2011
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torches. A series resonant half-bridge topology is presented as a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. A plasma torch rated at 3MW, 2kA and having a physical size of 1m is selected to be the high enthalpy source for a waste disposal system. The steady-state and transient operations of a plasma torch are simulated. The parameters of a Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. The circuit simulation waveform shows that the ripple of the arc current can be maintained within ${\pm}10%$ of its rated value under the presence of a load disturbance. This power conversion configuration provides a high enough ignition voltage, around 5KA, during the ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

A Study on the Development of Low Frequency Electronic Ignition Trans for Large Combustors (대형연소기에 적용되는 저주파 전자식 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • In this paper, the ignition trans used in boilers was studied. Regardless of the change in the ignition rod length and the ignition rod gap, the output frequency was measured between 59.5 and 61.3 Hz, and it was found that the low frequency circuit operated normally. When the ignition rod gap changed by 2 to 10 mm, the ignition rod length was measured from 2.8A to 3.45A at 30cm. The ignition rod length was measured from 9.37 A to 14.5 A at 500 cm and from 13.2 A to 32.6 A at 1000 cm. As the ignition rod length and the ignition rod gap increased, the current increased. As a result of measuring the secondary coil output voltage. The ignition rod length was measured from AC 0.84 kV to AC 1.75 kV at 30 cm, AC 1.17 kV to AC 1.944 at 500 cm, and AC 1.4 kV to AC 7.18 kV at 1000 cm. As the ignition rod length and the ignition rod gap increased, the output voltage of the secondary coil also increased. As a result of measuring the output voltage of the ignition trans, the ignition rod length was measured from DC 1.11 kV to DC 1.57 kV at 30cm, DC 2.49 kV to DC 3.72 kV at 500cm, and DC 3.78 kV to DC 9.42 kV at 1000cm, and the power voltage increased as the ignition rod length and interval increased.

Analysis of Electro-magnetic Wave radiating from an Ignition Plug and High-voltage Cable inside an Engine Room (자동차의 점화 플러그와 고압 케이블에서 발생하는 전자파에 대한 해석)

  • 최광제;조시기;정원락;장성국;강신한
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.209-215
    • /
    • 2004
  • This paper presents the frequency range and an analysis method to find the dominant source of electro-magnetic wave which originates from a spark ignition in engine room. Applying the distributed constant equivalent circuit theory the radiation of probable electro-magnetic wave around an ignition plug and a high voltage cable is studied analytically. Experimental studies are also conducted by measuring the frequency spectrum to obtain the radiating characteristics of electro-magnetic wave. Results from both analytical and experimental studies confirm that an ignition plug and a high voltage cable are dominant sources of electro-magnetic wave and that the radiating frequency is ranged from 1.3[GHz] to 2[GHz] band.