• 제목/요약/키워드: Ignition point

검색결과 211건 처리시간 0.037초

Characteristics of Spontaneous Combustion of Various Fuels for Coal-Fired Power Plant by Carbonization Rank

  • Kim, Jae-kwan;Park, Seok-un;Shin, Dong-ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권2호
    • /
    • pp.83-92
    • /
    • 2019
  • Spontaneous combustion propensity of various coals of carbonization grade as a pulverized fuel of coal-fired power plant has been tested from an initial temperature of $25^{\circ}C$ to $600^{\circ}C$ by heating in an oven with air to analyze the self-oxidation starting temperature. These tests produce CPT (Cross Point Temperature), IT (Ignition temperature), and CPS (Cross Point Slope) calculated as the slope of time taken for a rapid exothermic oxidation reaction at CPT base. CPS shows a carbonization rank dependence whereby wood pellet has the highest propensity to spontaneous combustion of $20.995^{\circ}C/min$. A sub-bituminous KIDECO coal shows a CPS value of $15.370^{\circ}C/min$, whereas pet coke has the highest carbonization rank at $2.950^{\circ}C/min$. The nature of this trend is most likely attributable to a concentration of volatile matter and oxygen functional groups of coal surface that governs the available component for oxidation, as well as surface area of fuel char, and constant pressure molar heat.

Hydroxypropyl Methyl Cellulose의 자연발화온도와 활성화 에너지에 관한 연구 (A Study on Spontaneous Ignition Temperature and Activation Energy of Hydroxypropyl Methyl Cellulose)

  • 임우섭;최재욱
    • 한국안전학회지
    • /
    • 제22권5호
    • /
    • pp.77-83
    • /
    • 2007
  • 식물류에 다량으로 함유되어 있는 Cellulose는 인체에 무해할 뿐 아니라 연소시에 발생하는 유해가스가 적어서 친환경적인 에너지 자원으로 대두되고 있다. 특히 Cellulose의 유도체 중 하나인 Hydroxypropyl Methyl Cellulose(HMC)는 의약품의 코팅재료를 비롯하여, 고급용 건축자재, 염료, 화장품 등의 첨가제로 사용되면서, 사용량이 계속해서 증가하고 있다. 따라서 여러 가지 위험에 노출될 수 있으며, 열적 위험특성을 알기 위한 방법으로 일본에서 많이 사용되고 있는 단열자기발열실험장치(SIT-II)를 이용하여 HMC의 한계발화온도와 겉보기활성화에너지를 구하였다. 또한 국제적으로 널리 알려진 Frank-Kamenetskii의 무한평판을 기준으로 한 자연발화실험(IF-SIT)자료를 이용하여 자연발화온도와 활성화 에너지 값을 비교하였다. HMC의 자연발화온도와 겉보기 활성화 에너지는 SIT-II의 경우 $186^{\circ}C$의 한계발화온도와 104.5kJ/mol의 활성화 에너지를 구하였다. 기존에 구하여진 IF-SIT결과 값과 비교하였을 때 무한평판의 두께 3cm, 5cm, 7cm에 대해 각각 한계발화온도가 $199.5^{\circ}C,\;188.5^{\circ}C,\;180.5^{\circ}C$이고, 167.4kJ/mol의 활성화 에너지 값을 지니므로, SIT-II로 구하여진 겉보기 활성화 에너지는 IF-SIT로 구하여진 값 보다 낮게 나타났으며, 이 값은 일반 Cellulose의 활성화 에너지 값 보다 도 더 낮은 것으로 나타났다.

스파크 플러그 케이블에서 복사되는 불요 전자파 감소 방안에 대한 실험적 연구 (An Experimental Study on the Reducing Method of Spurious Emission at the Spark Plug Cable)

  • 강상원;최광제;허정
    • 전기전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.10-15
    • /
    • 2013
  • 정상적인 불꽃 점화 시스템과 관통형 세라믹 콘덴서를 부가한 불꽃 점화 시스템에서 복사되는 전자파의 전력 스펙트럼의 측정 데이터를 분석한 결과 관통형 세라믹 콘덴서를 부가한 불꽃 점화 시스템에서 복사되는 전자파는 정상적인 불꽃 점화 시스템에서 복사되는 전자파 보다 약하고, 스펙트럼 밀도 또한 소하였다. 이것은 불꽃 점화 시스템에서 복사되는 불요 전자파를 관통형 세라믹 콘덴서가 감소시키는 것이라고 할 수 있으며, 고압의 펄스를 발생하는 점화 코일은 고주파를 발생하는 무선 주파 발진기라고 할 수 있다.

알코올화합물의 폭발하한계 추산에 관한 연구 (A Study on Estimation of Lower Explosive Limits of Alcohol Compounds)

  • Dong-Myeong Ha;Yong-Chan Choi;Haejin Oh;Su-kyung Lee
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 추계 학술논문발표회 논문집
    • /
    • pp.291-296
    • /
    • 2002
  • Flammable compounds are indispensible in domestic as well as in industrial fields as fuel, solvent and raw materials. The fire and explosion properties necessary for safe storage, transport, process design and operation of handling flammable substances are lower explosive limits(LEL), upper explosive limits(UEL), flash point, fire point, AIT(auto ignition temperature), MIE(minimum ignition energy), MOC(minimum oxygen concentration) and heats of combustion.

  • PDF

백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측 (Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp)

  • 이흥수;김두현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

성능위주설계에서 화재위험성 예측 과정의 문제점 및 개선방안 (The Problems and Improvements of Process to Predict Fire Risk of a Building in Performance Based Design)

  • 이세명
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.145-154
    • /
    • 2014
  • Performance based design(PBD) is the method to make a fire safety design against them after predicting the factors of fire risk in a building. Therefore, predicting fire risk in a building is very important process in PBD. For predicting fire risk of a building, an engineer of PBD must consider various factors such as ignition location, ignition point, ignition source, first ignited item, second ignited item, flash over, the state of door and fire suppression system. But, it is difficult to trust fire safety capacity of the design because the process in Korea' PBD is unprofessional and unreasonable. This paper had surveyed some cases of PBD that had been made in Korea to find the problems of the process to predict fire risk. And it have proposed the improvements of process to predict fire risk of a building.

바이오가스를 이용한 가스엔진 발전기의 발전효율 및 질소산화물 배출 특성 (Generating efficiency and NOx emissions of a gas engine generator fuelled with biogas)

  • 이경택;차효석;전광민;송순호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.306-309
    • /
    • 2009
  • Concern for new and renewable energy is growing globally. Biogas is one of the alternative fuels and consists of methane and carbon dioxide. It is difficult to achieve efficient engine operation due to a lower heating value of biogas compared to that of natural gas. In order to improve generating efficiency, finding an optimum point of ignition timing and excess air ratio is important. From this fact, generating efficiency and pollutant emissions of 2300cc gas engine generator operated by biogas as functions of ignition timings and excess air ratios were investigated in this study. As a test result, the generating efficiency of the gas engine generator using biogas was 27.34 % in the condition of the BTDC of $16^{\circ}$ and the excess air ratio of 1.4.

  • PDF

권총용 화약잔사의 실측 및 발화특성에 관한 연구 (A Study on Measuring Residues and Ignition Characteristics of the Gunpowder by Using a Handgun)

  • 송재용;최영우;김동환;남정우;김진표
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.102-106
    • /
    • 2010
  • 본 논문은 실내사격장 화재 원인에 대한 조사를 위하여 권총 사용에 따른 화약잔사 양에 대한 실측 및 발화특성에 관하여 연구하였다. 화약잔사 양은 구경 0.38인치 권총 및 구경 9mm 권총을 사용하였으며, 사대 및 바닥면에 떨어지는 화약잔사를 측정하였다. 화약잔사에 대한 발화특성 평가를 위하여 충격감도, 정전기감도, 마찰감도 및 발화점 시험을 실시하였으며, 비교 평가에는 권총에 일반적으로 사용되는 사용전의 화약(ball powder)을 이용하여 화약잔사와 동일한 시험을 실시하였다. 실험결과 충격감도 및 마찰감도는 화약잔사에서 다소 높게 측정되었으며, 발화점 시험에서는 화약잔사가 비교대상인 사용전의 화약에 비해 낮은 온도에서 발화되는 특성을 나타내었다.

이소부틸알코올(IBA)의 연소특성치 측정에 의한 MSDS의 적정성 연구 (The Study on the Compatibility of MSDS by Means of Measurement of Combustible Properties for Isobutylalcohol(IBA))

  • 하동명
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.75-81
    • /
    • 2014
  • 이소부틸알코올의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였으며, 인화점과 발화지연시간에 의한 자연발화온도는 장치를 이용하여 측정하였다. 공정에서는 이소부틸알코올의 폭발하한계는 1.7 Vol.% 그리고 상한계는 10.9 Vol.%가 사용되고 있다. 인화점의 경우 밀폐식 장치인 Setaflash와 Penski-Martens에 의한 하부인화점은 각 각 $25^{\circ}C$$30^{\circ}C$로 측정되었으며, 개방식인 Tag와 Cleveland 에서는 각 각 $36^{\circ}C$$39^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 이소부틸알코올의 최소자연발화온도는 $400^{\circ}C$로 측정되었다.