노말펜타데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Pentadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

승용 디젤엔진의 EGR과 Induction위치에 따른 소음 영향 (The Effects of EGR and EGR Induction Point on Combustion Noise of a Passenger Diesel Vehicle)

  • 강상규;김재헌;백성남;강구태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.393-396
    • /
    • 2007
  • EGR is well established and efficient means to reduce NOx emissions. The increase of EGR rate affects the ignition delay of the combustion due to the lower oxygen availability. The increasing of the ignition delay period causes large combustion noise. In this study, the effects of EGR and Induction Point on combustion noise are investigated by measuring cylinder pressure and noise. As a result, The Combustion noise is markedly increased under the application of EGR. The increased premixed distance by displacing EGR Induction point in flow direction causes the uniform EGR distribution and the modulation level of the combustion noise is reduced slightly.

  • PDF

노말트리데칸의 연소특성치의 적정성 고찰 (The Investigation of Compatibility of Combustible Characteristics for n-Tridecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.83-88
    • /
    • 2012
  • For the safe handling of n-tridecane, the lower flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower explosion limits by the lower flash points were calculated. The lower flash points of n-tridecane by using closed-cup tester were experimented $92^{\circ}C$ and $96^{\circ}C$. The lower flash points and fire point of n-tridecane by using open cup tester were experimented 100 oC and 103 oC, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tridecane. The experimental AIT of n-tridecane was 223 oC. The calculated lower explosion limit by using measured lower flash point 92 oC for n-tridecane was 0.6 Vol.%.

노말헥사데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Hexadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.39-45
    • /
    • 2014
  • For the safe handling of n-hexadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-hexadecane were calculated. The lower flash points of n-hexadecane by using the Setaflash and the Pensky-Martens closed testers were measured $128^{\circ}C$ and $126^{\circ}C$, respectively. The lower flash points of the Tag and the Cleveland open cup testers were measured $136^{\circ}C$ and $132^{\circ}C$, respectively. The fire points of the Tag and the Cleveland open cup testers were measured $144^{\circ}C$. respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-hexadecane. The experimental AIT of n-hexadecane was $200^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $128^{\circ}C$ and upper flash point $180^{\circ}C$ for n-hexadecane were 0.42 Vol.% and 4.70 Vol.%.

전자제어의 Event 처리방법에 관한 연구 (A Study on the Event Processing for Electronic Control)

  • 이종승;이중순;정성식;하종률
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.115-122
    • /
    • 1998
  • For digital engine control timings, such as ignition, are based on the crank shaft angle. Therefore, it is very important that the angle of the crank shaft can be detected with accuracy for optimal ignition timing. Sequential multi-point injection(MPI) systems that have independent injection events for each cylinder, are used to inject an accurate quantity of fuel, and to cope with varying engine status promptly. In this study the distributorless ignition timing. A crankshaft position sensor has been installed such that it generates a number of pulses per crankshaft revolution to permit accurate detection of the crank shaft angle. An event detecting algorithm has been developed, which detects the crank shaft pulses generated by the position sensor, and the software outputs the required control signals at given crank angle values. We clarified that the hardware method is the best way to increase the performance of the control system, because the event detecting duration T(1+2)max becomes zero.

  • PDF

주위온도 변화에 따른 입상활성탄의 자연발화에 관한 연구 (A Study on Autoignition of Granulated Activated Carbon with Change of Ambient Temperature)

  • 목연수;최재욱
    • 한국안전학회지
    • /
    • 제7권4호
    • /
    • pp.45-53
    • /
    • 1992
  • Sponataneous ignition characteristics for granulated activated carbon were observed by performing experiments at constant ambient temperature and varying the ambient temperature sinusoidally. In case of varying the ambient temperature sinusoidally, the amplitudes of temperature were 5$^{\circ}C$, 1$0^{\circ}C$ and 15$^{\circ}C$ respectively, and the period in each amplitude was varied at an interval of 30minutes from zero to 3hours. As the results of experiments at a constant ambient temperature, the critical spontaneous ignition temperature of the sample decreased as the sample vessel size increased. Apparent activation energy of the sample calculated from the Frank-Kamenetskii's thermal Ignition theory was 38.82[kca1/mo1] In case of varying the ambient temperature sinusoidally, the critical spontaneous ignition tempera-ture was lower than that at the constant ambient temperature, and the minimum critical spontaneous ignition temperature decreased with the amplitude of heating sinusoidal curve. At the same amplitude, the critical spontaneous ignition temperature decreased until it reached the minimum point and then in-creased as the period increased.

  • PDF

열복사에 의한 고체연료 점화 연구 (Ignition of a solid fuel by thermal radiation)

  • 김명효;백승욱
    • 대한기계학회논문집B
    • /
    • 제22권3호
    • /
    • pp.294-302
    • /
    • 1998
  • Ignition characteristics of a vertical solid fuel plate with block have been investigated experimentally. For low radiant heat flux, ignition does not occur in a vertical solid fuel plate without block. In the case with the block on a vertical fuel plate, however, ignition can occur by increasing the residence time and the time to absorb the incident radiation flux by fuel vapor in gas phase. The ignition occurs below block and the point varies according to the block location and the block height. As the block height increases, the block locates at higher position, and the hot wall temperature increases, the ignition delay time decreases. Also as the initial temperature of fuel plate rises, the ignition delay time of the solid fuel plate decreases. The temperature distribution of solid fuel plate with block is nearly proportional to the radiant heat flux distribution. Therefore, the effect temperature by natural convection heat transfer is of the same order as that of inhibition of temperature increase by pyrolysis.

오토크레졸의 MSDS 연소특성치의 적정성 연구 (A Study on the Appropriateness of the Combustible Properties of MSDS for o-Cresol)

  • 하동명
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.21-26
    • /
    • 2015
  • For the safe handling of o-cresol, this study was investigated the explosion limits of o-cresol in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of o-cresol by using closed-cup tester were experimented in $77^{\circ}C$ and $80^{\circ}C$. The lower flash points of o-cresol by using open cup tester were experimented in $86^{\circ}C$ and $87^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for o-cresol. The AIT of o-cresol was experimented as $495^{\circ}C$. The lower explosion limit(LEL) by the measured the lower flash point for o-cresol was calculated as 1.27 Vol%.

노말헥산의 연소특성치의 측정 및 고찰 (The Measurement and Investigation of Combustible Properties for n-Hexane)

  • 하동명
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.36-41
    • /
    • 2011
  • For the safe handling of n-hexane, the explosion limit at $25^{\circ}C$, the temperature dependence of the explosion limits and the lower flash point were investigated. And AITs(auto-ignition temperatures) by ignition delay time for n-hexane were experimented. By using the literatures data, the lower and upper explosion limits of n-hexane recommended 1.0 Vol% and 8.0 Vol%, respectively. In this study, the lower flash points of n-hexane recommended $-23^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-hexane, and the experimental AIT of n-hexane was $240^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of n-hexane is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

가연성 액체의 인화점과 화재특성치와의 관계 (The Relationship between Flash Point and Fire Properties of Flammable Liquids)

  • 송영호;하동명
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.10-14
    • /
    • 2007
  • 인화점은 가연성 액체의 화재 위험성을 평가하기 위해 사용되는 중요한 특성치 중의 하나이다. 가연성 액체의 상대적인 화재 위험성을 나타낼 수 있는 특성치로서는 열방출속도(HRR), 최대열방출속도(PHRR), 발화지연시간(TTI),질량 감소율, CO및 $CO_2$발생량 등이 있다. 본 연구에서는 가연성 액체의 가연성 액체의 인화점과 화재 특성치와의 관계에 대해서 검토하였다. 이를 위하여 질량 감소율과 TTI를 측정하여 화재 특성치를 계산하였다. 그 결과, 가연성 액체의 인화점과 TTI와 관련된 화재 특성치가 상관성이 매우 높은 것으로 나타났다. 이 결과로부터 가연성 액체 화재의 상대적인 위험성을 평가할 수 있는 파라미터로 사용할 수 있었다.

  • PDF