• Title/Summary/Keyword: Id-1

Search Result 1,048, Processing Time 0.036 seconds

A STUDY ON THE STRESS ANALYSIS OF THREE ROOT-FORM IMPLANTS WITH FNITE ELEMENT ANALYSIS (유한요소분석법을 이용한 치근형 임플랜트의 응력분포에 관한 연구)

  • Moon, Byoung-Hwa;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.129-150
    • /
    • 1993
  • Since the restoration or masticatory function is the most important aim of implants, it should be substituted for the role of natural teeth and deliver the stress to the bone under the continous load during function. In natural teeth, stress distribution can be obtained through enamel, dentin and cementum and the elasticity of the periodontal ligament play a role of buffering action. In contrast, implant prosthesis has a very unique characteristics that it delvers the load directly to bone through the implant and superstructure. This fact arise the needs to evaluate the stress distribution of the implant in the mechnical aspects, which has a similar role of natural teeth but different pathway of stress. With 3 kinds of implant in prevalent use, 2 types of experimental PEA implant models were made, axisymmetric and 2-dimensional type. In axisymmetric model, the stiffness of the part including the prosthesis and implant which extrude out of bony surface could be calculated with displacement of the superstructure un er 100N vertical load and then damping effects could be determined through this stiffness. In axisymmetric FEA model, load to the bone could be deduced by evaluation the stress distribution of the designed surface under the 100N vertical force and in 2-dimensional model, 100N eccentric vertical load and 20N horizontal loda. The result are as follows. 1. In every implant, stress to the bone tends to be concenturated on the cortical bone. 2. Though the stress of the cancellous bone is larger at the apex of implants, it is less compared with cortical bone. 3. Under 20N horizontal load, stress of the left and right sides of implant shows a symmetrical pattern. But under 100N eccentric vertical load, loaded side shows much larger stress value. 4. In the 1mm interface, stress distribution among implants tend to have a similar pattern. But under 20N horizontal load apposite side of being loaded shows less stress in IMZ. 5. In the case of screw type implant, stress tends to vary along with screw shape. 6. According to the result determined with microstrain, cancellous bone id generally under the condition of overload, while cortical bone is usually within the limitation of physiologic load. 7. In the Branemark implant, maximum stress to the cortical bone is larger than any other implant except for the condition of 20N horizontal force and 0.05mm interface. 8. Damping effects of implants is maximum in IMZ.

  • PDF

Implementation & Test Results analysis Of a DTV Distributed Translator(DTxR) Network (DTV 분산중계망의 구축 및 실험방송 결과분석)

  • Mok, Ha-Kyun;Wang, Soo-Hyun;Sung, Young-Mo;Lee, Yong-Tae;Lee, Yong-Hoon;Kim, Heung-Mook
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.518-536
    • /
    • 2009
  • To verify the performance of a Distributed Translator Network(DTxR) system in the real world conditions, 5 legacy DTV broadcasting repeater sites were implemented with 5 DTxR systems and field-tested by the DTV field test truck. The 4 DTV broadcasting repeater sites are selected in congested areas where their service areas are overlapped and the 5th site is deviated from the other sites to examine the effect of long-delayed multipath signals. First of all, we checked the receiving signal of the main station that used as a transmitting signal in 5 DTxR systems on the pre-selected 60 test points and tested every case of a DTxR system's on & off except 1 repeater site due to the already built-in DTV repeater system. The test items are received signal electric field strength, noise margin, ease of reception and subjective evaluation of the picture quality for received signals. We used 3rd, 5th, and 6th generation DTV receivers to examine the differences of the receivability by each generation of DTV receivers. Reviewing the test results, we conclude that the DTxR system can be adopted in the current DTV Repeater sites and it could improve the quality and receivability of the main signals by extending the service areas and enhancing the signal levels in the shadow areas without using the extra broadcasting channels.

Effect of L-Glutamic Acid and Paraben Solution on the Endothelial Cell Proliferation in the Glutaraldehyde- Fixed Bovine Pericardium (글루타르알데하이드 고정 소심 낭막에서의 내피세포 증식에 대한 글루탕산 및 파라벤용액의 효과)

  • Kim, Beom-Sik;Lee, Mun-Hwan;Yu, Se-Yeong;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.7-13
    • /
    • 1996
  • The conventional glutaraldehyde (GA) fixation method of tissue valves is considered to be responsible for accelerated valve degeneration. The release of toxic GA from the valve tissue is believed to limit endothelial cell (EC) ingrowth. Removal of toxic GA by reaction with L-glutamic acid and storage in a Paraben solution may offer good EC growth. To investigate the conditions for endothelialization of tissue valves, the growth properties of ECs on the conventionally and alternatively treated pericardial tissue were compared. Conventional preparation included zero-pressure fixation for 72 hours in phosphated-buffered saline (PBS) solution containing 0.5% GA at 4$^{\circ}C$ and storage into PBS containing 0.2% GA(group I). Alternatively treated pericardial tissues were divided into three postfixation treatment groups : (1) storage in PBS solution containing Paraben(group II), (2) treatment with PBS containing 8$^{\circ}C$ L-glutamic acid(PH 7.35) and storage in PBS solution containing Paraben (g oup III), (3) treatment with L-glutamic acid dissolved in distilled water (PH 3.5) (group IV). Pericardial tissue were transferred into the 24-well plate after storage for 4 weeks. ECs were harvested enzymatically from the bovine pulmonary artery and grown to confluence on culture flask surfaces. Detached ECs by trypsin were incubated into the each well of the 24-well plate including test pericardial tissues. Cells were detached by trypsin, 1, 2, 3, 5, 7 days after incubation and counted on the hemacytometer. Cell viability test was performed by frypan-blue exclusion method. Acute cell death in the group I were found even after prolonged washing. The group II showed prolonged cell survival compared with the group I. Both group III and group IV showed better cell growth than group II. There was no statistically significant difference between group III and group IV method in terms of EC growth. This results suggest that treatment by L-glutamic ac id and storage in a Paraben solution be a promising approach for improvement of durability of GA-treated tissue valves.

  • PDF

Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array (이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법)

  • 김강식;한호산;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.351-364
    • /
    • 2002
  • Conventional 3D ultrasound imaging using mechanical ID arrays suffers from poor elevation resolution due to the limited depth-of-focus (DOF). On the other hand, 3D imaging systems using 2D phased arrays have a large number of active channels and hence require a very expensive and bulky beamforming hardware. To overcome these limitations, a new real-time volumetric imaging method using curved 2-D arrays is presented, in which a small subaperture, consisting of 256 elements, moves across the array surface to scan a volume of interest. For this purpose, a 2-D curved array is designed which consists of 90$\times$46 elements with 1.5λ inter-element spacing and has the same view angles along both the lateral and elevation directions as those of a commercial mechanical 1-D array. In the proposed method, transmit and receive subapertures are constructed by cutting the four corners of a rectangular aperture to obtain a required image qualify with a small number of active channels. In addition the receive subaperture size is increased by using a sparse array scheme that uses every other elements in both directions. To suppress the grating lobes elevated due to the increase in clement spacing, fold-over array scheme is adopted in transmit, which doubles the effective size of a transmit aperture in each direction. Computer simulation results show that the proposed method can provide almost the same and greatly improved resolutions in the lateral and elevation directions, respectively compared with the conventional 3D imaging with a mechanical 1-D array.

Fabrication and characterization of the 0.25 ${\mu}m$ T-shaped gate P-HEMT and its application for MMIC low noise amplifier (0.25 ${\mu}m$ T형 게이트 P-HEMT 제작 및 특성 평가와 MMIC 저잡음 증폭기에 응용)

  • Kim, Byung-Gyu;Kim, Young-Jin;Jeong, Yoon-Ha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.38-46
    • /
    • 1999
  • o.25${\mu}m$ T-shaped gate P-HEMT is fabricated and used for design of X0band three stage monolithic microwave integrated circuit(MMIC) low noise amplifier(LNA). The fabricated P-HEMT exhibits an extrinsis transconductance of 400mS/mm and a drain current of 400mA/mm. The RF and noise characteristics show that the current gain cut off frequency is 65GHz and minimum noise figure(NFmin) of 0.7dB with an associated gain of 14.8dB at 9GHz. In the design of the three stage LNA, we have used the inductive series feedback circuit topology with the short stub. The effects of series feedback to the noise figure, the gain, and the stability have been investigated to find the optimal short stub length. The designed three staage LNA showed a gain of above 33dB, a noise figure of under 1.2dB, and ainput/output return loss of under 15dB and 14dB, respectively. The results show that the fabricated P-HEMT is very suitable for a X-band LNA with high gain.

  • PDF

A Study on the Synthesis of Potassium Hexatitanate Whisker by the Slow Cooling Calcination Process (서냉 소성법에 의한 육티탄산칼륨 Whisker의 합성에 관한 연구)

  • Lee, Chul-Tae;Choi, Ung-Su;Kim, Young-Myoung
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.160-175
    • /
    • 1994
  • Fibrous potassium hexatitanate whisker with the size of $ID=0.5{\sim}1{\mu}m$ and length=$100{\sim}1000{\mu}m$ (aspect ratio=100~1000) was produced through the reaction between titanium dioxide and potassium carbonate using the slow-cooling calcination followed by water leaching treatment. The optimum condition for the production of fibrous potassium titanate was calcination temperature of $1100^{\circ}C$ for 5hrs, $TiO_2$ mole ratlo to $K_2CO_3$ of 4.5 and slow-cooling rate of $0.5^{\circ}C/min$ to $860^{\circ}C$. Fibrous crystal are grown by the association between the solid potassium titanate and liquid phase during the slow-cooling process. The Proper water leaching condition for removing of K component was leaching time of 10hrs in boiling water. Pressurizing of the mixture of $K_2CO_3$ and $TiO_2$ to be calcinated became effective on the growth of fibrous crystal.

  • PDF

Identification of Potential Substrates of N-acteylglucosamine Kinase by a Proteomic Approach (프로테오믹스를 이용한 N-아세틸글루코사민 인산화효소 기질단백질의 동정)

  • Lee, HyunSook;Moon, Il Soo
    • Journal of Life Science
    • /
    • v.23 no.4
    • /
    • pp.586-594
    • /
    • 2013
  • Post-translational O-GlcNAc modification (O-GlcNAcylation) of serine or threonine is a new protein modulation mechanism. In contrast to the classical glycosylation, O-GlcNAcylation occurs in a one-step transfer of O-GlcNAc on both nuclear and cytoplasmic proteins. In contrast to the general consensus that O-GlcNAc is a final modification, a recent paper (J Proteome Res. 2011 10:2725-2733) showed the presence of O-GlcNAc-P on a synaptic assembly protein AP180. This finding raises a fundamental question about its prevalence. To address this question, we used proteomics to identify those proteins that were phospho-signal enriched by GlcNAc kinase (NAGK). Comparison of pDsRed2-$NAGK_{WT}$-transfected HEK293T cell extract with pDsRed2-$NAGK_{D107A}$-transfected control culture revealed 15 phospho-signal increased spots. Excluding those spots that had no detectable amount of protein expression yielded 7 spots, which were selected for ID determination. Among these, two duplicate spots (two $HSP90{\beta}$ and two ENO1 spots) were shown to be O-GlcNAcylated, two (dUTP nucleotidohydrolase mitochondrial isoform 2, glutathione S-transferase P) were not known to be involved in O-GlcNAcylation, and one (heat shock protein gp96 precursor or grp94) was a glycoprotein. The increase in the phospho-levels of O-GlcNAc by NAGK strongly indicates that these proteins are phosphorylated on O-GlcNAc. Our present data support the idea that O-GlcNAc is not a terminal modification.

Analysis of the Threshold Voltage Instability of Bottom-Gated ZnO TFTs with Low-Frequency Noise Measurements (Low-Frequency Noise 측정을 통한 Bottom-Gated ZnO TFT의 문턱전압 불안정성 연구)

  • Jeong, Kwang-Seok;Kim, Young-Su;Park, Jeong-Gyu;Yang, Seung-Dong;Kim, Yu-Mi;Yun, Ho-Jin;Han, In-Shik;Lee, Hi-Deok;Lee, Ga-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.545-549
    • /
    • 2010
  • Low-frequency noise (1/f noise) has been measured in order to analyze the Vth instability of ZnO TFTs having two different active layer thicknesses of 40 nm and 80 nm. Under electrical stress, it was found that the TFTs with the active layer thickness of 80 nm shows smaller threshold voltage shift (${\Delta}V_{th}$) than those with thickness of 40 nm. However the ${\Delta}V_{th}$ is completely relaxed after the removal of DC stress. In order to investigate the cause of this threshold voltage instability, we accomplished the 1/f noise measurement and found that ZnO TFTs exposed the mobility fluctuation properties, in which the noise level increases as the gate bias rises and the normalized drain current noise level($S_{ID}/{I_D}^2$) of the active layer of thickness 80 nm is smaller than that of active layer thickness of thickness 40 nm. This result means that the 80 nm thickness TFTs have a smaller density of traps. This result correlated with the physical characteristics analysis performmed using XRD, which indicated that the grain size increases when the active layer thickness is made thicker. Consequently, the number of preexisting traps in the device increases with decreasing thickness of the active layer and are related closely to the $V_{th}$ instability under electrical stress.

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).

Deep Learning based Fish Object Detection and Tracking for Smart Aqua Farm (스마트 양식을 위한 딥러닝 기반 어류 검출 및 이동경로 추적)

  • Shin, Younghak;Choi, Jeong Hyeon;Choi, Han Suk
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.552-560
    • /
    • 2021
  • Currently, the domestic aquaculture industry is pursuing smartization, but it is still proceeding with human subjective judgment in many processes in the aquaculture stage. The prerequisite for the smart aquaculture industry is to effectively grasp the condition of fish in the farm. If real-time monitoring is possible by identifying the number of fish populations, size, pathways, and speed of movement, various forms of automation such as automatic feed supply and disease determination can be carried out. In this study, we proposed an algorithm to identify the state of fish in real time using underwater video data. The fish detection performance was compared and evaluated by applying the latest deep learning-based object detection models, and an algorithm was proposed to measure fish object identification, path tracking, and moving speed in continuous image frames in the video using the fish detection results. The proposed algorithm showed 92% object detection performance (based on F1-score), and it was confirmed that it effectively tracks a large number of fish objects in real time on the actual test video. It is expected that the algorithm proposed in this paper can be effectively used in various smart farming technologies such as automatic feed feeding and fish disease prediction in the future.