• Title/Summary/Keyword: Ice storage

Search Result 299, Processing Time 0.023 seconds

Feasibility Study on Leveling Method of Electric Power Load by Applying Thermal Storage Air Conditioning System (축열식 열원시스템 적용에 의한 전력부하 평준화의 경제성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Reducing global warming potential has become important, and as one of those methods for reducing it, economic evaluation by applying ice thermal storage air conditioning system was performed. The floor area and height of the subject building was assumed $5,000m^2$ and 20 m. Absorption chillerheater system and air source heat pump system was used for comparing to the subject system, and payback period method was used to perform economic evaluation. Although the running cost of ice thermal storage system is reduced compared to two systems, the ratio is not significant compared to the increase of initial construction expenses, and payback period was calculated to be about 7.7 and 79.3 years. However, the heat storage system should be approached from the viewpoint of long term rather than the economic standard in the present standard.

An Evaluation of Chiller Control Strategy in Ice Storage System for Cost-Saving Operation (운전비 절감을 위한 빙축열시스템 냉동기 운전기법 평가)

  • Lee, Kyoung-Ho;Choi, Byoung-Youn;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • This paper presents simulated and experimental test results of optimal control algorithm for an encapsulated ice thermal storage system with full capacity chiller operation. The algorithm finds an optimal combination of a chiller and/or a storage tank operation for the minimum total operation cost through a cycle of charging and discharging. Dynamic programming is used to find the optimal control schedule. The conventional control strategy of chiller-priority is the baseline case for comparing with the optimal control strategy through simulation and experimental test. Simulation shows that operating cost for the optimal control with chiller on-off operation is not so different from that with chiller part load capacity control. As a result from the experimental test, the optimal control operation according to the simulated operation schedule showed about 14 % of cost saving compared with the chiller-priority control.

A Field Application Case of Direct Ice Slurry Transporting System for District Cooling (지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례)

  • Yoo, Ho-Seon;Lee, Sang-Hoon;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

Study on Ice Making Behavior of Water Solution with Surfactant (계면활성제 첨가수용액의 제빙에 관한 기초연구)

  • ;Hideo Inaba;Akihiko horibe
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1175-1183
    • /
    • 2001
  • Recently, a great attention has been paid to the ice thermal storage system for the purpose of energy saving and reduction in peak electrical demand. In the present study, it has been investigated the freezing behavior of several kinds of water solutions with nonionic surfactant. In order to prevent ice blockage in a cooled pipe, the amount and wall adhesion behavior of ice of the test fluids were observed experimentally under different concentration of water solution with surfactant, temperature of cooled wall, and the shear velocity of test fluids. The results showed that the size of ice crystal became smaller at higher shear velocity at wall. And the lowest limit of wall adhesion of ice in water solution with surfactant was found at 230 W/$m^2$ of heat flux.

  • PDF

Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System (아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 특성 분석)

  • Lee, Dong-Won;Lee, Soon-Myung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.111-115
    • /
    • 2006
  • To clarify the hydraulic and thermal characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flow in the double tube and plate type heat exchanger, experimental studies were performed. The mass flux and Ice fraction of ice slurry were varied from 800 to $3,500 kg/m^2s$(or 7 to 17 kg/min) and from 0 to 25%, respectively. During the experiment, it was found that the measured pressure drop and heat transfer rate increase with the mass flux and ice fraction; however the effect of ice fraction appears not to be significant at high mass flux region. At the region of low mass flux, a sharp increase in the pressure drop and heat transfer rate were observed depends on mass flux.

  • PDF

Effects of Ice Cooling Storage on Chemical Components in Vegetable Corn (풋옥수수의 얼음 저장이 종실성분 변화에 미치는 영향)

  • 손영구;김성열;김선림;황종진
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.1
    • /
    • pp.95-103
    • /
    • 1997
  • This experiment was carried out to obtain the basic information necessary to establish suitable postharvest handling techniques and to keep high quality of the sweet(Danok 2), supersweet(Cooktail 86) and waxy(Chalok 1) corn which are mainly consumed as vegetable in Korea. Vegetable corns were cooled with ice fragments in the insulation box immediately after harvest and stored in low temperature warehouse at 0 to 2$^{\circ}C$. During the 15 days short-term storage, changes of chemical components were compared with those of uncooled corns. The losses of moisture in kernels were as high as 7.4 to 24.4% in uncooled corns while those of ice cooled corns increased 0.4 to 0.5% of their weight. The ratio of pericarp and alcohol insoluble solid(AIS) content increased as the storage days prolonged in all treatments but increasing rates were much higher in uncooled samples. On the other hand, the total sugar loss during storage was the least in supersweet corn when they were cooled with ice fragments in insulation box. After 5 days storage, the ice cooled samples showed the highest free amino acid contents compare to those of uncooled and stored at room temperature (25 to 3$0^{\circ}C$) or low temperature warehouse, and ${\gamma}$-aminobutylic acid (GABA) which was known as a fuctional amino acid was detected in all three kinds of vegetable corns.

  • PDF

Effect of Partial Freezing as a Means of Keeping Freshness I. Changes in Freshness and Gel Forming Ability of Mullet Muscle during Storage by Partial Freezing (Partial Freezing에 의한 어육의 선도유지 효과에 대하여 1. Partial Freezing에 의한 숭어의 선도 및 어묵형성능의 변화)

  • LEE Yong-Woo;PARK Yeung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.529-537
    • /
    • 1985
  • The present study was carried out to investigate the effect of the partial freezing as a means of keeping freshness of mullet (Mugil cephlus). Living samples were killed and stored by icing, partial freezing at $-3^{\circ}C$ and freezing at $-30^{\circ}C$, respectively, Changes in the freshness of the mullet muscle and the phys cal properties of its meat paste product were examined during storage. The results obtained are summarized as follows: The period that k value reached to $20\%$ during storage was the longest in the frozen storage, followed by the partial frozen storage and the ice storage, which was 4 days in the mullet muscle stored by partial freezing. In the case of VBN content, it was below 20 mg/100g in the mullet muscle stored by icing and partial freezing. The oxidation of lipids in the mullet muscle was greater in the ice storage than in the partial frozen storage. The myofibrillar protein of the mullet muscle was appeared to decrease during storage, which the decreasing ratios during storage for 9 days were below $3\%$ in the frozen storage, $17\%$ in the ice storage and $10\%$ in the partial frozen storage. While, the alkali-soluble protein showed to increase and in non-protein nitrgenous compounds, sarcoplasmic protein and stroma was not a great change during storage. The decrease of gel strength, folding strength and texture of meat paste products prepared under different storage conditions was the greatest in the ice storage, the next in the partial frozen storage and such changes in the frozen storage were not so much. In gel strength of the product prepared with sample fishes stored for 10 days, the gel strength in the ice storage, partial frozen storage and frozen storage was about $30\%,\;60\%\;and\;97\%$ of the control. respectively. The expressible drip of the products increased with storage time of raw fishes, which that of the products prepared with sample fishes stored for 15 days was about 2.1 times in the ics storage, about 1.5 times in the partial frozen storage and about 1.1 times in frozen storage as much as that of the control, respectively.

  • PDF

A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System (저온 잠열 축열조내의 열유동 특성에 관한 연구)

  • Lee, W.S.;Park, J.W.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

Preparation of Ice at Home and Consumer's Demand for Auto Icemaker in Refrigerator (가정에서의 냉장고를 이용한 제빙 실태와 제빙 설비 개선에 대한 요구도 조사)

  • Lee, Young-Mee;Jang, Jeong-Ock
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.2
    • /
    • pp.211-220
    • /
    • 1997
  • This study was investigated about preparation of ice at home and developing points which met consumer's demand that was focused on auto icemaker. According to purposive quota sampling method, residences in Seoul and Kyunggi-do area were selected and interviewed by trained interviewer at August 1995. The results were as follows: 66.3% of respondent usually prepared ice in ice-making container of refrigerator and used when they needed. 85% of them used ice in summer and seldomly used in other seasons. Boiling water with barley was major drinking water(45.6%), and broiled or purified tap water was used to make ice(38.6%) commonly. Numbers of ice-making container were two(66.0%). Above 50% of respondents replied that they felt off-flavor in ice usually. After felt off-flavor, 54.7% of respondent threw away the ice, some of them used off-flavored ice after treatment to washing with water. 64.9% of respondents thought that the origins of off-flavor was the flavor of refrigerator itself. The consumer's expectation of developing points were as follows. The most priority of developing points was to make ice quickly, the next was to develop auto ice maker and ice storage container, to make different size of ice. Less expected points were to make more clear ice and large volume of ice in one time. The recognition about auto ice maker was slightly low(35% of respondents), but 67% of them wanted to develop auto ice maker.

  • PDF

Characteristic of the Formation and Adhesion of Ice on a Cooling Surface by a Stirring Aqueous Solution

  • Kang, Chae-Dong;Seung, Hyun;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.110-117
    • /
    • 2006
  • Ice adhesion or cohesion leads to the decrease of the performance of ice making system, especially to dynamic type ice thermal storage system (DISS) which mainly forms ice from the flow of an aqueous solution. The ice adhesion is influenced by various parameters associated with operating or geometric condition. In this study, the influence on an adhesion of ice to the characteristic of cooling surface and to composition of an aqueous solution was fundamentally observed by using batch type cooling device,. a beaker. Three patterns of solution in each beaker were cooled with brine. Moreover, the characteristic of cooling surface on each beaker was distinguished to coating materials. Stirring power as a degree of the ice adhesion was measured. The stirring power to cooling heat transfer rate in each beaker was compared. As a result, the lowest stirring power of 8.9 W with non-adhesion of ice, was shown in the case of the aqueous solution of EG(4) + PG(1.5) + 1,6HD(1.5). in PE coating beaker.