• 제목/요약/키워드: IUPAC

검색결과 31건 처리시간 0.026초

Preparation and Properties of Pelletized Activated Carbons Using Coconut Char and Coal-Tar Pitch

  • Yang, Seung-Chun;Lee, Young-Seak;Kim, Jun-Ho;Lim, Chul-Kyu;Park, Young-Tae
    • Carbon letters
    • /
    • 제2권3_4호
    • /
    • pp.176-181
    • /
    • 2001
  • A series of activated carbons were prepared from coconut shells and coal-tar pitch binder by physical activation with steam in this study. The effect of variable processes such as activation temperature, activation time and ratio of mixing was investigated for optimizing those preparation parameters. The activation processes were carried out continuously. The nitrogen adsorption isotherms at 77 K on pellet-shaped activated carbons show the same trend of Type I by IUPAC classification. The average pore sizes were about 19-21${\AA}$. The specific surface areas ($S_{BET}$) of pellet typed ACs increased with increasing the activation temperature and time. Specific surface area of AC treated for 90 min at temperature $900^{\circ}C$ was 1082 $m^2/g$. The methylene blue numbers continuously increased with increasing the activation temperature and time. On the other hand, iodine numbers highly increased till activation time of 60 min, but the rate of increase of iodine numbers decreased after that time. This indicates that new micropores were created and the existing micropores turned into mesopores and macropores because of increased reactivity of carbon surface and $H_2O$.

  • PDF

Comparison of the Mercury Intrusion Porosimerty, Capillary Flow Porometry and Gas Permeability of Eleven Species of Korean Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권6호
    • /
    • pp.681-691
    • /
    • 2018
  • The typical methods of mercury intrusion porosimetry (MIP) and capillary flow porometry (CFP) were used to evaluate the pore size of cross-section of wood and the effect of the pore structure on the permeability of wood was analyzed in this study. The results of this study were as followings: The pore size of wood measured by CFP was larger than that measured by MIP except for Lime tree, Korean red pine and Paulownia. Among the three pore types of porous materials defined by IUPAC (through pores, blind pores, and closed pores), only through pores are related to permit fluid flow. MIP measures the pore size of both through pores and blind pores, while CFP measures the pore size of only constricted through pores. Therefore, pore size measured by MIP was not related to gas permeability, however pore size measured by CFP had a proportional relationship with gas permeability.

대기 중 PCBs의 PAS에 이용되는 여러 매체의 PCBs 침착 특성 (Depositional Characteristics of Atmospheric PCBs in Several Media Used Passive Air Samplers)

  • 천만영
    • 한국환경보건학회지
    • /
    • 제39권2호
    • /
    • pp.151-158
    • /
    • 2013
  • Objective: This study was carried out to determine the depositional characteristics of pine needles, pine tree bark, moss, and soil, which are used as a passive air sampler (PAS) of atmospheric polychlorinated biphenyls (PCBs). Methods: All four media were sampled from the same site. PCB concentrations were analyzed by GC/MSD, and the lipid contents were measured using the gravimetric method. Results: The total PCB concentration (IUPAC No. 28, 52, 101, 138, 153, 180) was the highest in soil (227.97 pg/g dry), followed by pine needles (71.36 pg/g dry), pine tree bark (44.58 pg/g dry), then moss (21.91 pg/g dry). Pine needles contained the highest lipid contents (21.31 mg/g dry), whereas soil (10.01 mg/g dry), pine tree bark (4.85 mg/g dry), and moss (1.92 mg/g dry) contained less. The concentration of lower-chlorinated PCBs was relatively high in pine needles, pine tree bark and moss, but not in soil. The PCB concentrations were proportional to their lipid contents in pine needles, pine tree bark and moss, but a different trend was revealed in soil. Conclusions: The PCBs concentrations in the media were affected by various factors including atmospheric PCB concentrations, lipid contents, and depositional pathways. However, each of these factors had a varying influence depending on the type of medium.

Dual Column-HRGC/ECD를 이용한 식품 중 PCBs 오염 실태조사 (Analysis of PCBs in Food by Dual Column-HRGC/ECD)

  • 서정혁;김정미;홍무기;김창민;최동미
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.166-173
    • /
    • 2003
  • HRGC/ECD를 이용한 congener specific analysis 방법으로 국내 유통식품 중 PCBs의 오염실태를 조사하였다. Indicator PCB인 IUPAC #28, #52, #101, #118, #138, #153 및 #180 7종을 대상물질로 하였으며, 소고기, 돼지고기, 닭고기, 계란, 고등어, 조기, 멸치, 오징어, 바지락을 대상시료로 선정하여 서울, 부산, 광주 3개 지역에서 수집하였다. 채취한 시료는 균질화하여 알칼리 분해후 유기용매로 추출하여 지방을 분해하고 실리카겔 컬럼으로 정제하여 dual column-HRGC/ECD로 분석하였으며 검출된 시료에 대해서는 HRGC/MSD로 재확인하였다. 분석결과 고등어 등 어류 시료에서 미량수준 (0.0002~0.001 mg/kg)의 PCBs가 검출되었으며 주요 검출물질은 PCB #101과 PCB #118이었다.

PYE [2-(1-pyrenyl)ethyldimethylsilylated silica] Column HPLC and HR-GC-(micro) ECD in the Accurate Determination of Toxic Co-planar PCBs and Polybrominated Diphenyl Ethers (PBDEs)

  • Kannan, Narayanan;Hong, Sang-Hee;Oh, Jae-Ryoung;Yim, Un-Hyuk;Li, Donghao;Shim, Won-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.529-536
    • /
    • 2005
  • Measurement of toxicologically relevant polychlorinated biphenyl (PCB) congeners such as non-ortho(IUPAC#) 77, 81, 126, 169 and mono-ortho 105, 114, 118, 123, 156, 157, 189 and di-ortho 170, 180 and polybrominated diphenyl ethers (PBDEs) such as 47, 66, 85, 99, 100, 138, 153, 154 in environmental samples become almost mandatory in several countries now. However, most of the available methods involve expensive instrumentations such as HRGC-HRMS or ECNI-LRMS, apart from expensive extraction and clean-up (with large volume of solvents) steps. A method has been devised combining the analytical separation power of PYE [2-(1-pyrenyl)ethyldimethysilylated silica] column HPLC and high-resolution gas chromatographic techniques including micro-electron capture detection (ECD) and two dimensional gas chromatograpy-ECD techniques to determine these eco-toxic substances at parts-per-trillion (ppt) levels. This combination resolves co-elution of congeners that occur in disproportionate ratios (e.g. CB-110 and -77) and allows accurate congener-specific determination of target compounds. This method is cost effective as it requires only hexane, that in small quantities (10 mL) and GC-ECD. The elution and analysis time are optimized to less man hours. This method is effectively utilized in the analysis of co-planar PCBs and PBDEs from archived solvent extracts of samples previously analyzed for pesticides and PCBs. Structure based separation of contaminant classes improves GCECD determination at ppt levels.

PCBs 함유 변압기 절연유의 화학적처리 (Chemical Treatment of the PCBs-laden Transformer Insulation Oil)

  • 유건상;최종하;최진환
    • 한국환경과학회지
    • /
    • 제20권11호
    • /
    • pp.1499-1507
    • /
    • 2011
  • Practical disposal of transformer insulation oil laden with PCBs (polychlorinated biphenyls) by a chemical treatment has been studied in field work. The transformer insulation oil containing PCBs was treated by the required amounts of PEG (polyethylene glycol) and KOH, along with different reaction conditions such as temperatures and times. The reaction of PEG with PCBs under basic condition produces arylpolyglycols, the products of nucleophilic aromatic substitution. Removal efficiencies of PCBs in insulation oil before and after chemical treatment were examined. The removal efficiency of PCBs was very low at lower temperatures of 25 and $50^{\circ}C$. Under the reaction condition of PEG 600/KOH/$100^{\circ}C$/2hr, removal efficiency of PCBs was approximately 70%, showing completely removal of PCBs containing 7~9 chlorines on biphenyl frame which appear later than PCB IUPAC Number 183 (2,2',3,4,4',5',6-heptaCB) in retention time of GC/ECD. However, when increasing the reaction temperature and time to $150^{\circ}C$ and 4 hours, removal efficiency of PCBs reached 99.99% without any formation of PCDDS/PCDFs during the process. Such reaction conditions were verified by several official analytical institutions. In studying the reaction of PEG with PCBs, it confirmed that the process of chemical treatment led to less chlorinated PCBs through a stepwise process with the successive elimination of chlorines.

BTEX 분석용 토양 숙련도 표준시료(PTMs) 개발에 관한 연구 (A Study on the Development of Soil-based PTMs for Analysis of BTEX)

  • 이민효;이군택;이법열;이원석;김금희;홍석영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권5호
    • /
    • pp.15-25
    • /
    • 2013
  • In this study, two kinds of soil-based proficiency testing materials (PTMs), NICE-012L and NICE-012R were prepared and certified for Benzen, Toluene, Etylbenzene and Xylene with evaluation of uncertainties. In order to analyse BTEX (Benzen Toluene Etylbenzene Xylene) for the candidate materials, GC/MS was used after pretreatment according to methods of soil analysis by Ministry of Environment. For the homogeneity test among bottles in terms of candidate materials, ISO 13528 and IUPAC Protocol were used and according to the result, both candidate materials showed sufficient homogeneity. Also, the stability test over the candidate materials was accessed according to the ISO Guide 35 by classifying short-term and long-term stability and the result showed that both candidate materials showed decent stability. The reference values of the two candidate materials depending on BTEX components were derived from the average of the 11 samples that were used for verification of the samples' homogeneity. Uncertainty of measurement was combined by uchar that was caused by a characteristic value, $u_{bb}$ that was caused by between-bottle homogeneity, and $u_{stab}$ that was caused by stability, and then combined uncertainty ($u_{PTM}$) was multiplied to the coverage factor (k) derived from the effective degree of freedom from each factor that leads to expanded uncertainty (U) in about 95% of confidence level. The proficiency testing materials developed through this study were supplied to National Institute of Environmental Research (NIER) and utilized as an external proficiency testing materials for evaluating analysis capacity of soil agencies with specialty in terms of soil analysis approved by Minister of Environment.

살충제 buprofezin의 가수분해 반응 메카니즘 (Kinetics and mechanism of hydrolysis of insecticidal buprofezin)

  • 성낙도;유성재;최경섭;권기성
    • 농약과학회지
    • /
    • 제2권1호
    • /
    • pp.46-52
    • /
    • 1998
  • [ $45^{\circ}C$ ]의 15%(v/v) dioxane 수용액중에서 살충성 buprofezin(IUPAC : tert-butylimino-3-iso-propyl-5-phenylperhydro-1,3,5-thiadiazin-4-one)의 가수분해 반응속도상수와 pka상수(5.60)를 측정하고 pH-효과, 용매효과(m=0.34, n=2.45 및 $1{\gg}m$), 열역학적 활성화 파라미터(pH 4.0, ${\Delta}H^{\neq}$= 11.12 $kcal{\cdot}mol^{-1}$, ${\Delta}S^{\neq}$=-5.0e.u. 및 $E_{act.}$=11.76Kcal), 반응 속도식등의 반응 속도론적 및 생성물분석(1-isopropyl-3-phenyl urea) 등의 비속도론적 실험결과를 얻었다. 이들 자료의 검토로부터 pH 8.0이하의 산성용액에서는 특정($k_{H3O+}$)및 일반 산-촉매반응에 의한 $A-S_{E}2$형 및 A-2(또는 $A_{AC}2$)형 반응, 그리고 pH 9.0이상의 알카리성 용액에서는 일반염기 촉매반응($k_{H2O}$)에 의한 친핵성 첨가-제거 ($Ad_{N}-E$) 반응이 사면체($sp^{3}$) 중간체를 경유하는 궤도-조절 반응으로 진행되는 일련의 가수분해 반응메카니즘을 제안하였다. 또한, Buprofezin은 산성(pH8.0이하)용액보다 염기성(pH8.0이상) 용액중($k=10^{-8}sec.^{-1}$)에서 더욱 안정하였으며 $45^{\circ}C$의 중성(pH 7.0) 수용액 중에서 반감기($t=\frac{1}{2}$)는 약 3개월이었다.

  • PDF

대기 시료 중 PCBs 전 이성체 분석에 관한 연구 (Analysis of all PCB Congeners in Air Samples by HRGC/HRMS)

  • 김경수;송병주;김종국
    • 분석과학
    • /
    • 제16권4호
    • /
    • pp.309-319
    • /
    • 2003
  • 본 연구에서는 전주시 대기 시료를 대상으로 PCBs 209개 전 이성체를 분석하였다. 추출한 시료는 황산 실리카겔 및 활성탄 컬럼으로 정제하였으며 DB-5 컬럼 ($60m{\times}0.25mm{\times}0.25{\mu}m$)을 이용하여 고분해능 가스크로마토그래피 및 고분해능 질량분석기 (HRGC/HRMS)로 분석을 수행하였다. 대기 시료 중 PCBs 농도는 $0.003{\sim}0.163pg-TEQ/m^3$의 범위를 보였다. DB-5 컬럼을 사용하여 분석한 결과 총 162개의 피크가 검출되었고, 그 중 37개의 피크는 하나 이상의 이성체가 중복된 피크로 정성되었다. 또한, 독성을 가지고 있는 coplanar-PCB 중에서도 IUPAC No. 118/106과 105/127번의 분리가 어려워 coplanar-PCB 농도를 과대평가 할 가능성이 있는 것으로 나타났다. 발생원 시료 (Kanechlor와 소각로 배가스)와 대기 시료와의 coplanar-PCB 이성체 분포를 비교한 결과, PCB-81, 77, 126와 169이성체는 소각로 시료에서 높은 비율을 나타냈다.

국내 하천들의 수질, 하천 퇴적물, 주변 토양 및 별늑대거미 체내 중금속 축적량을 통한 환경오염도 평가 (Assessment of Environmental Contaminant Levels in Water, Sediments and Adjacent Soils and Spider from Several Stream Sites in Korea)

  • 변상혁;유건상;최종하;김용균;이화성
    • 한국환경과학회지
    • /
    • 제17권3호
    • /
    • pp.287-296
    • /
    • 2008
  • A comprehensive quality survey for heavy metals, organophosphorous and organochlorine residual pesticides, and coplanar PCBs in samples such as water, sediments and soils as well as spiders has been implemented. The samples were undertaken at nine stream sites and their vicinity in August 2006, representing different surrounding environments. The levels of PCBs were expressed as concentrations and WHO-TEFs. Among 12 coplanar PCBs as target compounds in this study, 2,3', 4,4', 5-PentaCB (IUPAC # 118) was the congener with the highest concentration. The total concentrations and TEF values of coplanar PCBs in Siheung stream sediment (heavy industrial complex site located in Ansan city) were 3915.50 pg/g and 0.8366 pg-TEQ/g on a dry weight basis, respectively. Such levels were around 40 times higher compared to sediment from Gapyung stream (green site located in the upper of Myunggi mountain). It is probably due to the direct input of PCBs trom PCBs treatment materials. Organophosphorous (EPN, dementon-s-methyl, diazinon, parathion, and phenthoate) and organochlorine (alpha-BHC, aldrin, 4,4'-DDT, 4,4'-DDE, endosulfan alpha and etc.) pesticides were not detected above 5 ppb of detection limits. The concentrations of Cu and Cd in water and sediment samples from Siheung stream were 44.11 and $0.17ug/m\ell$ and $713.42{\mu}g/g$ and $3.73{\mu}g/g$, respectively, which contained $20\sim40$ times higher concentrations than those from Gapyung stream. In addition to the water and sediment samples, the levels of heavy metals in spider from designated sampling sites were also determined. Heavy metals in spider collected near Siheung stream was appeared to be equivalent and/or a little higher levels with respect to other spiders. Furthermore, the ratio of relative heavy metals (Cu, Cd, and Pb) in spider from each stream site showed a correlation as similar as that of heavy metals in soil samples.