• Title/Summary/Keyword: ITS device

Search Result 3,937, Processing Time 0.034 seconds

Development of Pediatric VAD(VICT) and its in-vivo Test (소아용 좌심실 보조장치(VICT)의 개발 및 in-vivo 실험)

  • Lee, S.H.;Park, I.T.;Kim, S.H.;Lee, K.W.;Lee, K.H.;Ahn, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.207-212
    • /
    • 1996
  • We developed pneumatic blood pump and its driving system as a pediatric ventricular assist device. The blood pump is diaphragm type system and its blood contacting area is coated with Bio-Span. The driving unit Is consists of dual pumps, valves for the reliable blood pumping and its controller uses 80C196(Intel) as a main processor. The acute animal experiment was performed with dogs and its body weight is about 20 kg. The maximum cardiac output is about 2.1 l/min and the pressure and flow curves showed reliable operation as assist device.

  • PDF

A Study on Development of Non-Powered Horse Riding Device for Enhancement of Core Muscle (코어근육군 강화를 위한 무동력 승마운동기구개발에 관한 연구)

  • Lim, Young-Tae;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.353-361
    • /
    • 2015
  • Objective : The aim of this study was to develop the non-powered horse riding device and was to evaluate the elaborate its applicability throughout static structural and transient structural analysis of the outdoor core strength exercise equipment. Method : Fifteen college students (mass: $69.55{\pm}13.38kg$, height: $1.69{\pm}5.61m$, age: $21.42{\pm}1.83yrs$) rode the powered horse riding device and 14 college students (mass: $71.12{\pm}9.74kg$, height: $1.73{\pm}3.31m$, age: $22.50{\pm}1.47yrs$) rode the non-powered horse riding device for the comparison. All motion capture data was collected at 100 Hz using six infrared cameras and the muscular activities were collected using a Delsys Trigno wireless system. The peak forward/backward lean angle, range of motion anter/posterior and vertical COM(Center of mass) movement of trunk and pelvis segment, and muscle activities of six muscles were compared between the two devices by using independent t-test (p<.05). Results : Several kinematic variables (peak forward-backward lean angle and vertical COM movement of trunk and pelvis segment, range of motion of trunk) significantly different between non-powered and powered horse riding device. The muscle activities of Rectus abdominis and External oblique of abdomen on the non-powered horse riding device were significantly greater than those of the powered device. Conclusion : It was concluded that non-power horse riding device could give the effect of core strength exercise as well as the body motion which can simulate the powered horse riding device.

Application of Modified Vacuum Assisted Closure with Silver Materials in Chronic Infected Wound (만성 감염성 창상에 대한 변형 음압요법과 은이온 제재의 이용)

  • Park, Gun Wook;Jeong, Jae Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.393-399
    • /
    • 2008
  • Purpose: Chronic infected wounds sustained over 4 weeks with exposed tendon or bone are difficult challenges to plastic surgeons. Vacuum assisted closure (VAC) device has been well used for the management of chronic wounds diminishing wound edema, reducing bacterial colonization, promoting formation of granulation tissue and local blood flow by negative pressure to wounds. But Commercial ready-made VAC device might have some difficulties to use because of its high expenses and heavy weight. So we modified traditional VAC device with silver dressing materials as topical therapeutic agents for control of superimposed bacterial wound infection such as MRSA, MRSE and peudomonas. Methods: We designed the modified VAC device using wall suction, 400 cc Hemovac and combined slow release silver dressing materials. We compared 5 consecutive patients' data treated by commercial ready-made VAC device(Group A) with 11 consecutive patients' data treated by modified VAC device combined with silver dressing materials(group B) from September 2004 to June 2007. Granulation tissue growth, wound discharge, wound culture and wound dressing expenses were compared between the two groups. Results: In comparison of results, no statistical differences were identified in reducing rate of wound size between group A and B. Wound discharge was significantly decreased in both groups. Modified VAC device with silver dressing materials showed advantages of convenience, cost effectiveness and bacterial reversion. Conclusion: In combination of modified VAC device and silver dressing materials, our results demonstrated the usefulness of managing chronic open wounds superimposed bacterial infection, cost effectiveness compared with traditional VAC device and improvement of patient mobility.

A Study on the Improvement of the Reports on Details of Supply of Medical Device System Through Selective Application (선별적 적용을 통한 의료기기 공급내역보고 제도 개선 연구)

  • Hyun Ju Jeong;Soo Yeon Lim;Ju Wan Kim;Won Seuk Jang;Byeong-Ju Kwon
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.315-323
    • /
    • 2023
  • The objective of this study is to identify the selective application targets for reporting on details of supply of class 1 and 2 medical devices as part of the improvement of the reports on details of supply of medical device system, and to analyze its effectiveness. Therapeutic materials covered by health insurance and secondhand medical devices were chosen based on the transparency of health insurance coverage and the management of medical device distribution. As a result, approximately 85% of groups can be excluded from the reporting requirements compared to reporting all items under Class 1 and 2 medical devices. This is expected to enhance the efficiency of supply reporting tasks. Additionally, the information on supply details managed by the regulatory authority can be utilized for statistical analysis and periodic monitoring, serving as fundamental data for the development of medical device-related policies and research in the field of medical devices.

A New Device and Procedure for Kinematic Calibration of Parallel Manipulators

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1615-1620
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise. Intrinsic inaccuracies of the device can significantly deteriorate the calibration results. A measurement procedure is proposed and formulations of cost functions are discussed to prevent propagation of the inaccuracies to the calibration results.

  • PDF

Fabrication of triboelectric nanogenerator for self-sufficient power source application (자가발전활용을 위한 마찰전기 나노발전소자의 제작)

  • Shin, S.Y.;Kim, S.J.;Saravanakumar, Balasubramaniam
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.589-590
    • /
    • 2013
  • The fast development of electronic devices towards wireless, portable and multi-functionality desperately needs the self-powered and low maintenance power sources. The possibility to coupling the nanogenerator to wearable and portable electronic device facilitates the self powered device with independent and self sustained power source. Nanogenerator has ability to convert the low frequency mechanical vibration to electrical energy which is utilized to drive the electronic device [1]. The self powered power source has the ability to generate the power from environment and human activity has attracted much interest because of place and time independent. The human body motion based energy harvesting has created huge impact for future self powered electronics device applications. The power generated from the human body motion is enough to operate the future electronic devices. The energy harvesting from human body motion based on triboelectric effect has simple, cost-effective method [2, 3] and meet the required power density of devices. However, its output is still insufficient to driving electronic devices in continues manner so new technology and new device architecture required to meet required power. In the present work, we have fabricated the triboelectric nanogenerator using PDMS polymer. We have studied detail about the power output of the device with respect to different polymer thickness and varied separation distance.

  • PDF

The measurement temperature and analysis used embedded system by internet explorer (인터넷 익스플로러를 통한 임베디드 시스템 기반의 온도 측정 및 분석)

  • 김희식;김영일;설대연;남철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1003-1006
    • /
    • 2004
  • In this paper have developed a system for monitoring and processing the real time sensor data in remote site through network. For realizing this system, measurement equipment and protocol are used to transmit the measurement data to remote server and to process measurement data. In server part, the received data from remote site sensor is converted to text or graphic charts for user. The measurement device in sensor part receives the sensor data form sensor and store the received data to its internal memory for transmitting data to server part through Internet. Also the measurement device can receive data form server. The temperature sensor is connected to the measurement device located in laboratory and the measurement device measures temperature of laboratory which can be confirmed by user through Internet. We have developed a server programworking on the Linux to store measurement data from measurement device to server memory. The program is use for SNMP(Simple Network Management Protocol) to exchange data with measurement device. Also the program changes the measurement data into text and graphic charts for user display. The program is use apache PHP program for user display and inquiry. The real time temperature measurement system can be apply for many parts of industry and living.

  • PDF

Automatic Measurement of Temperature in Real Time by Using an Internal and Data Processing System (인터넷을 이용한 원격 실시간 온도 계측 모니터 및 계측데이터 자동처리 시스템)

  • Kim, Hui-Sik;Kim, Yeong-Il;Seol, Dae-Yeon;Nam, Cheol;O, Heung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.99-102
    • /
    • 2003
  • In this paper, we have developed a system for monitoring and processing the real time sensor data in remote site through Internet. For realizing this system, measurement equipment and protocol are used to transmit the measurement data to remote server and to process measurement data. In server part, the received data from remote site sensor is converted to text or graphic charts for user. The measurement device in sensor part receives the sensor data form sensor and store the received data to its internal memory for transmitting data to server part through Internet. Also the measurement device can receive data form server. The temperature sensor is corrected to the measurement device located in laboratory and the measurement device measures temperature of laboratory which can be confirmed by user through Internet. We have developed a server program working on the Linux to store measurement data from measurement device to server memory. The program is use for SNMP(Simple Network Management Protocol) to exchange data with measurement device. Also the program changes the measurement data into text and graphic charts for user display. The program is use apache PHP program for user display and inquiry. The real time temperature measurement system can be applly for many parts of industry and living.

  • PDF

A Study About Design and Characteristic Improvement According to P-base Concentration Charge of 500 V Planar Power MOSFET (500 V 급 Planar Power MOSFET의 P 베이스 농도 변화에 따른 설계 및 특성 향상에 관한 연구)

  • Kim, Gwon Je;Kang, Ye Hwan;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.284-288
    • /
    • 2013
  • Power MOSFETs(Metal Oxide Semiconductor Field Effect Transistor) operate as energy control semiconductor switches. In order to reduce energy loss of the device during switch-on state, it is essential to increase its conductance. We have experimental results and explanations on the doping profile dependence of the electrical behavior of the vertical MOSFET. The device is fabricated as $8.25{\mu}m$ cell pitch and $4.25{\mu}m$ gate width. The performances of device with various p base doping concentration are compared at Vth from 1.77 V to 4.13 V. Also the effect of the cell structure on the on-resistance and breakdown voltage of the device are analyzed. The simulation results suggest that the device optimized for various applications can be further optimized at power device.

Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Seo, Jihyeon;Lee, Byunghun;Lee, Dongkyu;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.279-282
    • /
    • 2020
  • In this study, body pressure was quantitatively detected using built-in optical sensors, inside an air cushion seat. The proposed system visualizes the effect of the body pressure distribution on the air cushion seat. The built-in sensor is based on the time-of-flight (ToF) optical method, instead of the conventional electrical sensor. A ToF optical sensors is attached to the bottom surface of the air-filled cells in the air cushion. Therefore, ToF sensors are durable, as they do not come in physical contact with the body even after repeated use. A ToF sensor indirectly expresses the body pressure by measuring the change in the height of the air-filled cell, after being subjected to the weight of the body. An array of such sensors can measure the body pressure distribution when the user sits on the air cushion seat. We implemented a prototype of the air cushion seat equipped with 7 ToF optical sensors and investigated its characteristics. In this experiment, the ToF optical pressure sensor successfully identified the pressure distribution corresponding to a sitting position. The data were accessed through a mobile device.