• Title/Summary/Keyword: IT evaluation

Search Result 30,395, Processing Time 0.076 seconds

Evaluation of Spatial and Temporal Variations of Water Quality in Lake Shihwa and Outer Sea by Using Water Quality Index in Korea: A Case Study of Influence of Tidal Power Plant Operation (수질평가지수를 이용한 시화호 내측 및 외측 해역의 시·공간적 수질 변화 평가: 조력발전소 가동에 따른 영향 연구)

  • Ra, Kongtae;Kim, Joung-Keun;Kim, Eun-Soo;Kim, Kyung-Tae;Lee, Jung-Moo;Kim, Sung-Keun;Kim, Eu-Yeol;Lee, Seung-Yong;Park, Eun-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.102-114
    • /
    • 2013
  • The basin of Lake Shihwa is one of highly industrialized region of Korea and a current environmental issue of study area is the operation of tidal power plant (TPP) to improve water quality. The application of water quality index (WQI) which integrates five physiochemical parameters (transparency, DO, DIN, DIP and chlorophyll-a) of water quality in Lake Shihwa and outer sea during 2011~2012 were performed not only to evaluate the spatial and temporal distribution of the water quality but also to assess the effect of water quality improvement by the operation of tidal power plant. The higher WQI values were observed in monitored sites near the industrial complexes in Lake Shihwa and the outfall of wastewater treatment plants (WWTPs) in outer sea. This indicates that the quality of seawater is influenced by diffuse non-point sources from industrial, municipal and agricultural areas in Lake Shihwa and by point sources from the effluence of municipal and industrial wastewater throughout WWTPs in outer sea. Mean WQI value decreased from 53.0 in 2011 to 42.8 in 2012 of Lake Shihwa. Water quality has improved significantly after TPP operation because enhancement of seawater exchange between Lake Shihwa and outer sea leads to improve a hypoxic condition which is primarily a problem in Lake Shihwa. Mean WQI of outer sea showed similar values between 2011 and 2012. However, the results of hierarchical cluster analysis and the deterioration of water quality in summer season indicate that the operation of tidal power plant was not improved the water quality in the upper most area of Lake Shihwa. To successfully improve overall water quality of Lake Shihwa, it is urgently necessary to manage and reduce of non-point pollution sources of the basin of Lake Shihwa.

A study on usage status of auxiliary oral hygiene devices in service workers behavior (일부 서비스 종사자들의 구강위생보조용품의 사용실태에 관한 조사 연구)

  • Kim, Myung-Eun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.3
    • /
    • pp.37-52
    • /
    • 2008
  • The purpose of this study was to provide basic data for oral health promotion of service worker and their effective interpersonal relationships forming through the evaluation about service workers' awareness of the auxiliary oral hygiene devices and using behavior of it. The survey was carried out questionnaire research targeting 400(service group 200, non-service group 200) and compared the two groups. The obtained results were as follow: 1. brushing behavior showed the highest ratio of 3~4 times/day(53.4%) in brushing frequency, up-down method(50.8%) in brushing method, after 5 minutes after the meals(45.0%) in brushing time, shape brush(56.6%) in brush change time. 2. service group used a lot more auxiliary oral hygiene devices than non-service group(50.9%). the frequency of use was toothpick(30.9%), gargle(29.9%), floss(13.5%), tongue cleaner(10.1%). 3. In comparison of two group about state of use, service group showed more higher ratio of floss(66.1%), tongue cleaner(64.4%), gargle(56.6%) than non-service group. non-service group showed more higher ratio of toothpick(54.6%) than service group 4. Service group used auxiliary oral hygiene devices by suggestions of dental clinic(53.6%) and didn't use them because of uncomfortable to use(45.4%) or didn't know how to use(21.6%). 5. As result of the awareness-related using rate of auxiliary oral hygiene devices, service group showed higher using ratio except toothpick than non-service group. especially gargle(54.8%), tongue cleaner(43.3%), floss(35.8%) were showed high. 6. service group took a regular checkups more than non-service group and showed the highest ratio of each 1 year(43.5%) in checkup period.

  • PDF

Quality Characteristics of Emulsion-Type Sausage Containing Pine Needle, Perilla Leaves and Green Tea Powder (솔잎, 깻잎 및 녹차분말이 함유된 유화형 소시지 품질특성)

  • Kim, I.K.;Jin, S.K.;Hah, K.H.;Lyou, H.J.;Park, K.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.667-678
    • /
    • 2005
  • This study was carried out to investigate the effects of addition of functional material(T1; pine needle powder, 0.4%, T2; perilla leaves powder, 0.4%, T3; green tea powder, 0.4%) on the quality characteristics of emulsion-type sausages. The samples were stored at $9{\pm}1^{\circ}C$ for 40 days and analyzed with an interval of 10 days. The pH of all emulsion-type sausages increased as storage period increased. Water holding capacity(WHC) of all treatments were slightly increased as storage period increased and rapidly decreased on 40 days of storage. In texture analysis, hardness, chewiness, gumminess and brittleness were increased with storage in all treatments group. TBARS values of T3 was lower than those of other treatments at 1 days of storage, while that was the slightly higher in T4 at 40 day of storage. The L* values was decreased as storage period increased. The a* values was highest in C, while it was the lowest in T2 and T3. The residual nitrite content of all samples were in very safe range during the whole storage period. During the storage period 40 days, the Lactobacilli spp. of C were higher($10^7$CFU/g) than those of 3 treatments. In sensory evaluation, the score of overall acceptability were higher in the order of C(5.5-6.5)>T1(4.8-6.0)>T2(4.8-5.8)>T3(4.3-4.8). In the manufacture of functional sausage containing pine needle, perilla leaves and green tea powder, further studied are needs on addition type/ratio of functional materials and the use of added spices.

Evaluation of Odors and Odorous Compounds from Liquid Animal Manure Treated with Different Methods and Their Application to Soils (액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가)

  • 고한종;최홍림;김기연;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.453-466
    • /
    • 2006
  • To comply with stricter regulations provoked by increasing odor nuisance, it is imperative to practice effective odor control for sustainable livestock production. This study was conducted to assess odor and odorous compounds emitted from liquid animal manure with different treatment methods such as Fresh Manure(without treatment, FM), Anaerobic Digestion(AD) and Thermophilic Aerobic Digestion(TAD) and their application to soil. Air samples were collected at the headspace of liquid manure, upland and paddy soil, and analyzed for odor intensity and offensiveness using an olfactometry; odor concentration index using odor analyser; nitrogen-containing compound such as ammonia(NH3) using fluorescence method; and sulfur containing compounds such as hydrogen sulfide(H2S), methyl mercaptan(MeSH), dimethyl sulfide(DMS) and dimethyl disulfide(DMDS) using gas chromatography-pulsed flame photometric detector, respectively. Odor intensity, offensiveness and concentration index from TAD liquid manure was statistically lower than those from FM and AD(p<0.01). Mean concentrations of H2S, MeSH, DMS, DMDS and NH3 were 65.93ppb, 18.55ppb, 5.26ppb, 0.33ppb and 10.57ppm for liquid manure with AD; and 5.15ppb, 0.97ppb, 0.80ppb, 0.56ppb and 1.34ppm for liquid manure with TAD, respectively. More than 60% of malodorous compounds related to nitrogen and sulfur were removed by heterotrophic microorganisms during TAD treatment. When liquid manure was applied onto upland and paddy soil, NH3 removal efficiencies ranged from 51 to 94% and 22 to 91% for AD and TAD liquid manure, respectively. The above results show that liquid manure with TAD is superior to AD and FM with respect to the odor reduction and odor problem caused by land applied liquid manure is directly related to the degree of odor generated by the manure treatment method.

Study on Genetic Evaluation using Genomic Information in Animal Breeding - Simulation Study for Estimation of Marker Effects (가축 유전체정보 활용 종축 유전능력 평가 연구 - 표지인자 효과 추정 모의실험)

  • Cho, Chung-Il;Lee, Deuk-Hwan
    • Journal of Animal Science and Technology
    • /
    • v.53 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • This simulation study was performed to investigate the accuracy of the estimated breeding value by using genomic information (GEBV) by way of Bayesian framework. Genomic information by way of single nucleotide polymorphism (SNP) from a chromosome with length of 100cM were simulated with different marker distance (0.1cM, 0.5cM), heritabilities (0.1, 0.5) and half sibs families (20 heads, 4 heads). For generating the simulated population in which animals were inferred to genomic polymorphism, we assumed that the number of quantitative trait loci (QTL) were equal with the number of no effect markers. The positions of markers and QTLs were located with even and scatter distances, respectively. The accuracies of estimated breeding values by way of indicating correlations between true and estimated breeding values were compared on several cases of marker distances, heritabilities and family sizes. The accuracies of breeding values on animals only having genomic information were 0.87 and 0.81 in marker distances of 0.1cM and 0.5cM, respectively. These accuracies were shown to be influenced by heritabilities (0.87 at $h^2$ =0.10, 0.94 at $h^2$ =0.50). According to half sibs' family size, these accuracies were 0.87 and 0.84 in family size of 20 and 4, respectively. As half sibs family size is high, accuracy of breeding appeared high. Based on the results of this study it is concluded that the amount of marker information, heritability and family size would influence the accuracy of the estimated breeding values in genomic selection methodology for animal breeding.

Effect of Sodium ion on the Anaerobic Degradation of Food Waste : Quantitative Evaluation, Inhibition Model (주방폐기물의 혐기성분해에 대한 나트륨이온의 영향: 저해 특성평가, 저해모델)

  • Shin, Hang-Sik;Song, Young-Chae;Paik, Byeong-Cheon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.2
    • /
    • pp.3-17
    • /
    • 1994
  • The inhibitory effect of sodium ion on the anaerobic degradation of food waste was studied by an anaerobic batch toxicity assay and inhibition model. The anaerobic degradation activity of food waste spiked with over $2g\;Na^+/L$ of sodium ion was severely inhibited at the initial stage of the exposure. The inhibition response of anaerobic microorganisms on the sodium ion estimated from the methane production was differed according to the concentration of sodium ion. The relative acclimation time(RAT) and methanation rate(RMR), defined as the ratios of initial lag time and maximum methane production rate of the sample spiked with sodium ion to the control. respectively, were used to evaluate the acclimation and inhibitory effects quantitatively on the anaerobic microorganisms. When sodium ion was increased from $2g\;Na^+/L$ to $20g\;Na^+/L$, the RAT was exponentially increased from 18.9 to 90. but the RMR was linearly decreased from 0.97 to 0.02. The effects of sodium ion for the maximum methanation rate, first order kinetic constant and ultimate methane production were well evaluated by a generalized nonlinear expression model. it could be described by the uncompetitive inhibition mode. The sodium ion concentration causing 50% inhibition of methanation activity was about $11g\;Na^+/L$, and the critical sodium ion beyond to compelete inhibition was 20 to $21g\;Na^+/L$. The presented results could be used to obtain the design or operation parameters of the anaerobic process treating food waste of high salt.

  • PDF

Residual characteristics of tolclofos-methyl treated by seed dressing in ginseng (인삼 중 종자분의 처리 tolclofos-methyl의 잔류 특성)

  • Noh, Hyun-Ho;Lee, Jae-Yun;Park, So-Hyun;Lee, Kwang-Hun;Park, Hyo-Kyoung;Oh, Jae-Ho;Im, Moo-Hyeog;Kwon, Chan-Hyeok;Lee, Joong-Keun;Woo, Hee-Dong;Kwon, Ki-Sung;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.217-221
    • /
    • 2012
  • This study was carried out to evaluate residual characteristics of tolclofos-methyl in ginseng and elucidate the reason for its high detection rate from fresh ginseng selling at markets. Seeds of ginseng were sowed after seed dressing with tolclofos-methyl and after a year of growth, the young seedlings were transplanted to field. They were then harvested annually until three-years of growth and the pesticide residue was analyzed in them. LOD and LOQ of the pesticide were 0.001 and 0.003 mg/kg, respectively. Recovery test was carried out to validate the analytical method for tolclofos-methyl in ginseng. The ginseng seedlings were fortified with the test pesticide at the level of LOQ, ten times of LOQ and maximum residue concentration of tolclofos-methyl. Its recovery ranged from 77.37 to 100.16%. Residual concentration of tolclofos-methyl in ginseng seedlings just before transplanting and two-year-old ginseng were from 7.58 to 8.05 and from 6.46 to 6.79 mg/kg, respectively. In case of three-year-old ginseng, it was found to be from 4.18 to 4.35 mg/kg. As a result of annual pesticide residue analysis, concentration of the pesticide was found to decrease time-coursely in ginseng. This may be due to decomposition and increasing of fresh weight of the ginseng during the cultivation periods of three years.

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD (뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가)

  • Bae, Yong-Ki;Bang, Dong-Wan;Park, Byung-Moon;Kang, Min-Yeong;Kim, Yeon-Rye
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.109-113
    • /
    • 2008
  • Purpose: To evaluate the detector dependency in the various collimator size for Stereotactic Radiosugery (SRS). Materials and Methods: This study was performed with 6 MV photon beam (Varian 21EX, Varian, US) and the measurement detectors are used by ion chamber CC01, CC13 (Wellhofer, Germany) and stereotactic diode detector (SFD, Wellhofer, Germany). SRS collimator size was used by ${\varphi}$5, 10, 20, 30 mm (Brain Lab, Germany). Percentage depth dose (PDD) was measured at SSD 100 cm and field size 10×10 cm from individual detectors. Ouput factor was measured by using same setup of PDD and with maximum dose depth. Data was normalized at field size $10{\times}10\;cm$. Beam profile was measured at SSD 100 cm in SRS collimator ${\varphi}$10, 30 mm and field $10{\times}10\;cm$ and a comparison of FWHM (full width half maximum), penumbra width (20~80%). Results: The CC13 detector was overestimated 16% than other detectors from the PDD in the 5 mm collimator. Output factors were underestimated CC01 28%, CC13 72% in the 5 mm collimator and CC01 9.6%, CC13 25% in the 10 mm collimator than the SFD. Maximum difference was 3% at the FWHM of the dose profile in the 10 mm collimator and difference of the 30 mm collimator was 0% at the FWHM. Penumbra width was increased CC01 122%, CC13 194% in the 10 mm collimator and CC01 68%, CC13 185% in the 30 mm collimator than the SFD. Conclusion: It is very important for accurate dosimetry to select a detector in small field. The SFD was considered with the most accurate dosimeter for small collimator dosimetry in this study.

  • PDF