• Title/Summary/Keyword: IT Evaluation Measurement

Search Result 2,318, Processing Time 0.032 seconds

Assessment and Validation of the Reliability of Quality Measurement System for Wireless Data Services (무선데이터 서비스 품질 측정 시스템의 신뢰성 검증 및 평가)

  • Choi, Dong-Hwan;Park, Seok-Cheon
    • Journal of Information Technology Services
    • /
    • v.11 no.1
    • /
    • pp.239-246
    • /
    • 2012
  • The user increases around the WiBro and in which the mobile broad band service is the wireless internet base technology HSDPA, that is the cellular phone foundation technique, and moreover the issue about the user effective quality guarantee emerges but the quality control of the wireless network is the incomplete actual condition. Therefore, the reliability verification according to the development of the system for the performance measure for the continued wireless data service and it and evaluation are needed for the quality control. In this paper, the wireless data service quality measurement system was implemented with the design. The same test environment as the existing network performance measurement program was built for the reliability verification of the embodied device for measuring quality and evaluation and the cost performance was performed. It could confirm that design and embodied wireless data service quality measurement system operated accurately in this paper through the quality measure result value analysis.

Factor Structure, Validity and Reliability of The Teacher Satisfaction Scale (TSS) In Distance-Learning During Covid-19 Crisis: Invariance Across Some Teachers' Characteristics

  • Almaleki, Deyab A.;Bushnaq, Afrah A.;Altayyari, Basmah A.;Alshumrani, Amenah N.;Aloufi, Ebtesam H.;Alharshan, Najah A.;Almarwani, Ashwaq D.;Al-yami, Abeer A.;Alotaibi, Abeer A.;Alhazmi, Nada A.;Al-Boqami, Haya R.;ALhasani, Tahani N.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.7
    • /
    • pp.17-34
    • /
    • 2021
  • This study aimed to examine the Factor Structure of the teacher satisfaction scale (TSS) with distance education during the Covid-19 pandemic, as well as affirming the (Factorial Invariance) according to gender variable. It also aimed at identifying the degree of satisfaction according to some demographic variables of the sample. The study population consisted of all teachers in public education and faculty members in higher education in the Kingdom of Saudi Arabia. The (TSS) was applied to a random sample representing the study population consisting of (2399) respondents. The results of the study showed that the scale consists of five main factors, with a reliability value of (0.94). The scale also showed a high degree of construct validity through fit indices of the confirmatory factor analysis. The results have shown a gradual consistency of the measure's invariance that reaches the third level (Scalar-invariance) of the Measurement Invariance across the gender variable. The results also showed that the average response of the study sample on the scale reached (3.74) with a degree of satisfaction, as there are no statistically significant differences between the averages of the study sample responses with respect to the gender variable. While there were statistically significant differences in the averages with respect to the variable of the educational level in favor of the middle school and statistically significant differences in the averages attributed to the years of experience variable in favor of those whose experience is less than (5) years.

Promoting Quality Awareness Based on Performance Measurements

  • Shin, Wan-Seon
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.345-352
    • /
    • 1998
  • Performance measurement is increasingly becoming a vital issue for promoting quality management within an organization. This research proposes a new performance measurement approach, called the Hierarchically Associated Performance Measurement, for the organizations which emphasize long term quality thrust through a balanced interface between the quality efforts of various units. The proposed approach is unique in that it considers relationships between internal quality activities and national quality award criteria and that it identifies and utilizes the quality responsibilities of functional units in order to encompass organizational roles in the evaluation process. The approach is illustrated via a numerical evaluation of a fictitious organization.

  • PDF

Development of the system for error evaluation in coordinate measuring machines (3차원 좌표 특정기의 오차 평가 시스템 개발)

  • ;M.Burdekin;G.Peggs
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.116-120
    • /
    • 1991
  • Technique of length measurement error is widely used in the accuracy assessment of CMMS(Coordinate measuring machines) and machine tools, as it is simple and direct measurement within the working volume of a machine. In this paper, a new method is proposed for the evaluation of the length measurement error in relation to the volumetric accuracy. lD, 2D, and 3D measuring lines are considered for recpective length measurement error: 1D, 2D, and 3D length measurement uncertainties are evaluated from volumetric accuracy. The relationship between the volumetric accuracy md length measurement error to is discussed. PC based system for length measurement error evaluation and simulation is developed.

  • PDF

Measurement and Evaluation of Vibration of the Ship Propulsion Machinery (ISO 20283-4) (선박 추진기계의 진동 계측과 평가(ISO 20283-4))

  • Lee, D.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.560-564
    • /
    • 2009
  • This paper introduces measurement and evaluation of vibration of the ship propulsion machinery (ISO 20283-4). ISO 20283-2 for measurement of structural vibration on ships was finalized last year and ISO 20283-4 was drafted and reviewed by particulate ISO members now. As the importance and core field in ISO 20283-4, the torsional vibration of propulsion system for sea going vessels should be analysed in design stage and it should be confirmed by the its measurement during the sea trial. Criteria for evaluation of torsional loadings are defined by IACS (International Association of Classification Societies) UR M68. In this paper, the author introduced the important and controversial matters during the review of ISO 20283-4.

  • PDF

A Study on the Measurement of the Winding Resistance Influences the Efficiency Evaluation of 3phase Induction Motors (삼상유도전동기 권선저항 측정이 효율 산출에 미치는 영향에 관한 연구)

  • Kang, Byung-Guk;Kim, Kwang-Min;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • 3phase induction motor consumes 40% of national electric power. so It is one of the most important electric device for the national power policy. The efficiency measurement is carried out by IEC standards. After the temperature rise test, It's difficult to measure the winding resistance immediately. because of inertia and power cut-off time. Therefore, IEC standards suggest the measurement time. But during the measurement time, the winding temperature cools down. It causes the value of winding resistance is variable. Several conditions which possibly occurred by the measurement time of IEC 60034-1 are suggested. and The efficiency evaluation of 3phase induction motors is carried out by IEC 60034-2-1 with the several conditions. As the results, we find out the winding resistance rapidly goes down within 15 sec. so It proves that the winding resistance should be measured within 15 sec. for the efficiency evaluating of 3phase induction motor.

The Impact of If Project Types and Ownerships on IT Value Evaluation (IT 프로젝트 유형과 오너쉽이 IT 가치평가에 미치는 영향)

  • 이국희;구본재
    • Journal of Information Technology Applications and Management
    • /
    • v.9 no.3
    • /
    • pp.79-95
    • /
    • 2002
  • As the budget size and complexity of 1T investment are growing, IT value measurement becomes more critical to the success of IT management In public organizations and private firms. It has been known that there are many factors such as IT costs, risks, qualify, and usage that should be taken Into consideration during the process of measuring IT value and making IT Investment decisions. However, little research has been done so far In order to analysis factors affecting the IT value and effectiveness. The purpose of this study Is to Investigate the impact of IT Project types and ownerships on IT value evaluation. The three research questions are as follows : (1) Does IT project type such as transactional, Informational, and infrastructure have any impact on 1T value measurement\ulcorner (2) Does the IT development ownership has any Impact on IT value\ulcorner (3) Does the IT operation ownership has any impact\ulcorner The empirical research was done at S-Electronics, world-wide known and the biggest manufacturing company in Korea, based on the method of structured interview. About 200 individual Information systems have been evaluated to calculate ROI measures, the dependent variable In this study. The results of statistical analysis show that two of three Independent variables, IT project types and IT development ownership, have statistically significant effects on IT value in terms of ROI measures.

  • PDF

Development of Posture Evaluation System through Digital Recognition Method (디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발)

  • Moon, Young-Jin;Lee, Soon-Ho;Back, Jin-Ho;Lee, Jong-Gak;Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.

A Case Study on Selection and Improvement of SLA Evaluation Metrics (SLA 평가 지표 선정과 개선 방안에 관한 사례 연구)

  • Shin, Sung-Jin;Rhew, Sung-Yul;Kim, Yoo-Ri
    • The KIPS Transactions:PartD
    • /
    • v.16D no.4
    • /
    • pp.541-548
    • /
    • 2009
  • Many companies have recently apply SLA and execute IT service by using SLA. However, there are no objective standards for selection and improvement of SLA evaluation metrics. We derive and present measurement attributes that are criteria for selection and improvement of SLA evaluation metrics as measurement metrics. We execute a case study based on D company in order to verify whether the measurement metrics are applicable. We apply and evaluate the measurement metrics that are applicable to D company, and then we designate an improvement line. We propose improvement guidelines of the measurement metrics which score is less than the improvement line's and derive SLA evaluation metrics. We prove that the way of selection and improvement is useful by applying SLA evaluation metrics to D company.

Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer (초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구)

  • 송치문;장한기;김승한;채장범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF