• Title/Summary/Keyword: IT/IS

Search Result 320,470, Processing Time 0.3 seconds

Fermentation Properties and Increased Health Functionality of Kimchi by Kimchi Lactic Acid Bacteria Starters (김치 유산균 Starter를 이용한 김치의 발효 특성 및 기능성 증진 효과)

  • Bong, Yeon-Ju;Jeong, Ji-Kang;Park, Kun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1717-1726
    • /
    • 2013
  • Fermentation characteristics and health functionalities of kimchi by inoculating kimchi lactic acid bacteria (LAB) starters were studied. We manufactured single LAB starter kimchi (Lactobacillus plantarum pnuK, Lactobacillus plantarum 3099K, Leuconostoc mesenteroides pnuK), mixed LAB starter kimchi (Lb. plantarum pnu/Leu. mesenteroides pnuK, Lb. plantarum 3099/Leu. mesenteroides pnuK) with inoculum size of $10^6$ CFU/g, as well as naturally fermented kimchi (NK), and fermented them for 6 days at $15^{\circ}C$. The pH and acidity of the early phase of fermentation were not different, but kimchi with the starters showed rapid changes in the pH and acidity from 2 days of fermentation. As the fermentation progressed, the level of total aerobic bacteria and Lactobacillus sp. increased similarly with or without Lb. plantarum (LP) inoculation. However, the level of Leuconostoc sp. was high in kimchi inoculated with Leuconostoc sp. starter. In the sensory evaluation test, kimchi with starters received higher overall acceptability scores than those of NK; mixed starter added kimchi earned the highest score. In DPPH and hydroxyl radical scavenging activity, kimchi with the starters exhibited higher activity than that of NK. In the MTT assay of HCT-116 and HT-29 human colon cancer cells, NK showed inhibition rates of 63.4 and 51.9%, but LPpnuK achieved 77.1 and 68.8%, respectively. This study showed that inoculating starters in kimchi increased in vitro antioxidant and anticancer activities, and single starter (LP) added kimchi revealed higher functionality than the kimchi with mixed starter. Kimchis with the starters effectively up-regulated the gene expressions of the pro-apoptotic gene of Bax, but down-regulated Bcl-2. They promoted expressions of p53 and p21, and suppressed expressions of inflammation-related genes, iNOS and COX-2, compared with NK. Taken together, it is expected that using starters may help manufacture kimchi with improved sensory quality and health functionality.

The Quality Characteristics of Rice Mash by Mixing Ratios of Rice and Rice Koji (쌀과 미입국의 배합비율에 따른 쌀 당화액의 품질특성)

  • Kim, Jin-Sook;Lee, Ji-Hyun;Chang, Young-Eun;Kim, Gi-Chang;Kim, Kyung-Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.2035-2041
    • /
    • 2013
  • The effects of Aspergillus oryzae rice koji (AO) and Asp. kawachii rice koji (AK) as enzyme preparations, on the quality characteristics of rice mash were invested in this study. The amount of AORM (Asp. oryzae rice mash) and AKRM (Asp. kawachii rice mash) were 50, 100, 200% (w/w) based on 100 g of rice. Firstly, in the titer measurement result on the ${\alpha}$-amylase and glucoamylase activities of AO and AK. On the other hand, the acid protease activity has values of 31.56 unit for AO and 849.17 unit for AK. The sugar solid of the AORM and AKRM groups significantly increased as the rice koji ratio on rice was higher, which were shown with values as high as 17.63~20.53 and 17.51~19.28, respectively. Glucose and maltose were detected for free sugar of AORM. Only glucose was found in AKRM. Citric acid, malic acid, and lactic acid were detected as the organic acid of KORM; oxalic acid, citric acid, and succinic acid were detected for AKRM, and the content increased as the rice koji ratio on rice increased (P<0.05). From the above result, rice koji with useful mold is expected to be used broadly in foods by looking at the fact that it has starch degradation ability and organic acid producibility.

Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry (소조사면에서의 불균질 물질 보정 계산의 평가)

  • Shin, Hun-Joo;Kang, Young-Nam;Jang, Ji-Sun;Seo, Jae-Hyuk;Jung, Ji-Young;Choi, Byung-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.

  • PDF

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

Estimation of CyberKnife Respiratory Tracking System Using Moving Phantom (동적 팬톰을 이용한 사이버나이프 호흡동기 추적장치의 위치 정확성 평가)

  • Seo, Jae-Hyuk;Kang, Young-Nam;Jang, Ji-Sun;Shin, Hun-Joo;Jung, Ji-Young;Choi, Byong-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il;Lim, Jong-Soo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.324-330
    • /
    • 2009
  • In this study, we evaluated accuracy and usefulness of CyberKnife Respiratory Tracking System ($Synchrony^{TM}$, Accuray, USA) about a moving during stereotactic radiosurgery. For this study, we used moving phantom that can move the target. We also used Respiratory Tracking System called Synchrony of the Cyberknife in order to track the moving target. For treatment planning of the moving target, we obtained an image using 4D-CT. To measure dose distribution and point dose at the moving target, ion chamber (0.62 cc) and gafchromic EBT film were used. We compared dose distribution (80% isodose line of prescription dose) of static target to that of moving target in order to evaluate the accuracy of Respiratory Tracking System. We also measured the point dose at the target. The mean difference of synchronization for TLS (target localization system) and Synchrony were $11.5{\pm}3.09\;mm$ for desynchronization and $0.14{\pm}0.08\;mm$ for synchronization. The mean difference between static target plan and moving target plan using 4D CT images was $0.18{\pm}0.06\;mm$. And, the accuracy of Respiratory Tracking System was less 1 mm. Estimation of usefulness in Respiratory Tracking System was $17.39{\pm}0.14\;mm$ for inactivity and $1.37{\pm}0.11\;mm$ for activity. The mean difference of absolute dose was $0.68{\pm}0.38%$ in static target and $1.31{\pm}0.81%$ in moving target. As a conclusion, when we treat about the moving target, we consider that it is important to use 4D-CT and the Respiratory Tracking System. In this study, we confirmed the accuracy and usefulness of Respiratory Tracking System in the Cyberknife.

  • PDF

The Effect on Pulmonary Indices of Surfactant Therapy for Meconium Aspiration Syndrome: Systematic Review and Meta-analysis (태변흡인증후군에서 폐표면활성제 사용이 호흡기지표에 미치는 영향에 대한 체계적 문헌고찰과 메타분석)

  • Choi, Hyun-Jin;Hahn, Seo-Kyung;Lee, Soon-Min;Kim, Han-Suk;Bae, Chong-Woo
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 2011
  • Purpose: Surfactants have been used to improve oxygenation for infants with meconium aspiration syndrome (MAS). We evaluated the change of pulmonary indices after surfactant therapy for MAS through a systematic meta-analysis. Methods: Relevant randomized controlled studies (RCTs) were identified by database searches in MEDLINE, EMBASE, and CENTRAL, up to June 2011, and by additional hand searches. Data were extracted regarding pulmonary indices, such as the oxygen index and arterial alveolar oxygen gradient. Meta-analyses were separately conducted for the studies of surfactant lavage therapy and surfactant bolus therapy. The risk of bias was assessed, and clinical as well as statistical heterogeneities were also investigated. Results: Two RCTs for bolus surfactant therapy and two RCTs for surfactant lavage therapy were identified. The oxygenation index results were heterogeneous between the two studies in which bolus surfactant therapy was given, while a/A $PO_2$ showed significantly better results in the treatment group over time after use of surfactant (12 hours: WMD 0.08, 95% CI 0.04-0.12; 24 hours: WMD 0.17, 95% CI 0.06-0.28). For surfactant lavage therapy, both studies consistently suggested an interventional benefit in terms of the pulmonary indices although it did not reach statistical significance. Conclusion: Surfactant therapy appeared to improve oxygenation of infants with MAS. Since a limited number of RCTs are available in the current literature and those studies were also clinically heterogeneous in terms of illness severity and the method of surfactant use, further research is needed to gather evidence to support surfactant therapy in MAS.

Patterns of FDG Uptake in Stomach on F-18 FDG Positron Emission Tomography: Correlation with Endoscopic Findings (F-18 FDG Positron Emission Tomography에서 보이는 위(stomach) 섭취 양상의 임상적 의의: 위 내시경 소견과 비교 평가)

  • Chae, Min-Jeong;Cheon, Gi-Jeong;Lee, Sang-Woo;Byun, Byung-Hyun;Kim, Sung-Eun;Kim, Yu-Chul;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.456-463
    • /
    • 2005
  • Purpose: we often find variable degrees of FDG uptake and patterns in stomach, which can make difficult to distinguish physiologic uptake from pathologic uptake on FDG PET. The purpose of this study was to find out the significant findings of stomach on FDG PET. Materials and Methods: Thirty-eight patients who underwent both FDG PET and endoscopy within one week from Jun. 2003, to Aug. 2004 were included in this study. We reviewed 38 patients (18 for medical check up, 15 for work up of other malignancies, and 5 for the evaluation of stomach lesion). Their mean age was 56 years old (range:$32{\sim}79$), men and women were 28 and 10, respectively. Two nuclear physicians evaluated five parameters on FDG PET findings of stomach with a consensus: 1) visual grades 2) maximum SUV (max.SUV) 3) focal 4) diffuse and S) asymmetric patterns. We correlated the lesions of FDG PET findings of stomach with those of endoscopy. We considered more than equivocal findings on FDG PET as positive. Results: The six of 38 patients were proven as malignant lesions by endoscopic biopsy and others were inflammatory lesions (ulcer in 3, chronic atrophic gastritis in 12, uncommon forms of gastritis in 5), non-inflammatory lesions (n=3), and normal stomach (n=9). By the visual analysis, malignant lesions had higher FDG uptake than the others. The max.SUV of malignant lesions was $7.95{\pm}4.83$ which was significantly higher than the other benign lesions ($2.9{\pm}0.69$ in ulcer, $3.08{\pm}1.2$ in chronic atrophic gastritis, $3.2{\pm}1.49$ in uncommon forms of gastritis (p=0.044)). In the appearance of stomach on FDG PET, malignant lesions were shown focal (5 of 6) and benign inflammatory lesions were shown diffuse (9 of 20) and asymmetric (14 of 20). Benign lesions and normal stomach were shown variable degrees of uptake and patterns. Some cases of benign inflammatory lesions such as ulcer and gastritis were shown focal and mimicked cancerous lesion (4 of 15). Conclusion: Gastric malignant lesions had higher FDG uptake and focal pattern. However, benign inflammatory lesions had moderate degrees of uptake and diffuse and asymmetric patterns rather than focal. It is difficult to differentiate between benign lesions including normal.

Development of Regularized Expectation Maximization Algorithms for Fan-Beam SPECT Data (부채살 SPECT 데이터를 위한 정칙화된 기댓값 최대화 재구성기법 개발)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Soo-Jin;Kim, Kyeong-Min;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.464-472
    • /
    • 2005
  • Purpose: SPECT using a fan-beam collimator improves spatial resolution and sensitivity. For the reconstruction from fan-beam projections, it is necessary to implement direct fan-beam reconstruction methods without transforming the data into the parallel geometry. In this study, various fan-beam reconstruction algorithms were implemented and their performances were compared. Materials and Methods: The projector for fan-beam SPECT was implemented using a ray-tracing method. The direct reconstruction algorithms implemented for fan-beam projection data were FBP (filtered backprojection), EM (expectation maximization), OS-EM (ordered subsets EM) and MAP-EM OSL (maximum a posteriori EM using the one-step late method) with membrane and thin-plate models as priors. For comparison, the fan-beam protection data were also rebinned into the parallel data using various interpolation methods, such as the nearest neighbor, bilinear and bicubic interpolations, and reconstructed using the conventional EM algorithm for parallel data. Noiseless and noisy projection data from the digital Hoffman brain and Shepp/Logan phantoms were reconstructed using the above algorithms. The reconstructed images were compared in terms of a percent error metric. Results: for the fan-beam data with Poisson noise, the MAP-EM OSL algorithm with the thin-plate prior showed the best result in both percent error and stability. Bilinear interpolation was the most effective method for rebinning from the fan-beam to parallel geometry when the accuracy and computation load were considered. Direct fan-beam EM reconstructions were more accurate than the standard EM reconstructions obtained from rebinned parallel data. Conclusion: Direct fan-beam reconstruction algorithms were implemented, which provided significantly improved reconstructions.

Effects of Aqueous Azadirachta indica Extract on Hepatotoxicity in Rats (수용성 님추출물이 랫드의 간 독성에 미치는 영향)

  • Park, Kyung-Hun;Yoon, Hyunjoo;Han, Beom Seok;Lee, Je-Bong;Jeong, Mi Hye;Cho, Namjun;Om, Ae Son;Paik, Min-Kyoung
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.395-402
    • /
    • 2014
  • BACKGROUND: Azadirachta indica Extract(AIE) containing azadirachtin as active ingredient have been used worldwide as environment-friendly organic material having pest control properties. However, the extracts prepared with different solvent and from different plant site is very diverse and have different toxicity. METHODS AND RESULTS: In this study, the four week repeated oral dose toxicity test of aqueous AIE in Sprague-Dawley rats was carried out to investigate the toxic effect of liver, main toxicity target organ of AIE. The male and female rats were divided into 4 groups, respectively; control(0 g/Kg bw), low-dose group(0.5 g/Kg bw), middle-dose(1.0 g/Kg bw) and high-dose group(2.0 g/Kg bw). As a results, relative liver weight increased with dose-dependent of AIE(p<0.05). Serum LDH in all AIE-treated groups were significantly lower than the control in male rats(p<0.05). However, serum GOT and GPT were significantly increased in all male AIE-treated groups in male rats(p<0.05) and, in particular, increase of serum GPT in dose-dependent manner raise the possibility of liver damage. Even through serum GLU was increased significantly in high-dose group in male rats compared to control, there were no significant differences of urinary GLU among all groups(p<0.05). In addition, histopathological examination of the liver did not reveal any lesions in all AIE-treated groups. CONCLUSION: In conclusion, 4 weeks of the repeated oral administration of AIE 2.0 g/Kg to rats has resulted no toxic response in liver. Therefore, AIE was no indicated to have any toxic effect in the SD rats, when it was orally administrated below the dosage 2.0 g/Kg/day for 4weeks.

Development of an Official Analytical Method for Determination of Aclonifen in Agricultural Products Using GC-ECD (GC-ECD를 이용한 농산물 중 제초제 aclonifen의 공정분석법 확립)

  • Ko, Ah-Young;Kim, Hee-Jung;Jang, Jin;Lee, Eun-Hyang;Joo, Yoon-Ji;Kwon, Chan-Hyeok;Son, Young-Wook;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.388-394
    • /
    • 2014
  • BACKGROUND: Aclonifen is used as a systemic and selective herbicide to control a wide spectrum broad-leaf weeds by inhibition carotenoid biosynthesis, and then its MRLs(Maximum Residue Limits) will be determined in onion and garlic. In this study, a new official method was developed for aclonifen determination in agricultural products to routinely inspect the violation of MRL as well as to evaluate the terminal residue level. METHODS AND RESULTS: Aclonifen was extracted from crop samples with acetone and the extract was partitioned with dichloromethane and then purified by silica solid phase extraction(SPE) cartridge. The purified samples were detected GC using an ECD detector. Limits of detection(LOD) was 0.001 mg/kg and quantification(LOQ) was 0.005 mg/kg, respectively. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n=5). The recoveries were ranged from 74.3 to 95.0% with relative standard deviations(RSDs) of less than 8%. All values were consistent with the criteria ranges requested in the Codex guidelines(CAC/GL 40). CONCLUSION: The proposed analytical method was accurate, effective and sensitive for aclonifen determination and it will be used to as an official method in Korea.