• 제목/요약/키워드: ISO-834 standard heating

검색결과 17건 처리시간 0.029초

지하주차장의 내화성능 평가를 위한 차량연소실험 (The combustion test of assuming in parking space for fire resistance)

  • 강승구;김동준;이재영;原田和典;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

가열속도에 따른 콘크리트 내부의 수분이동이 폭렬발생에 미치는 영향 (Effect of Moisture Migration in Concrete with Hating Rate on Concrete Spalling)

  • 최경철;김규용;남정수;김홍섭;윤민호;황의철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.246-247
    • /
    • 2017
  • In this study, it reviewed the effect of moisture migration in concrete with heating rate on concrete spalling. Concrete specimens with compressive strength 30MPa and 110MPa are used and its size is □100×100×h200mm. And, two kinds of heating rate are set such as IS0 834 and 1℃/min. As a result, in the concrete specimen exposed to ISO 834 standard heating condition, moisture could migrate through pore network and surface concrete pieces fall out by generating moisture clog near the surface in 110MPa concrete specimen. Meanwhile, In the case of concrete specimens exposed to 1℃/min. heating condition, it is appeared that moisture could not migrate because temperature is distributed uniformly. Therefore, surface spalling is not occurred with low heating rate. However, in the case of 110MPa concrete specimen is exploded even though it heated by low heating rate.

  • PDF

가열을 받은 초고강도 콘크리트 기둥부재의 잔골재 종류에 따른 내부온도이력 및 잔존압축강도 평가 (Evaluation on Temperature History and Residual Compressive Strength of Heated Ultra High Strength Concrete Column according to the Fine Aggregate Type)

  • 윤민호;김규용;신경수;최경철;이보경;미야우치 히로유키
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2013
  • The strength of ultra-high-strength concrete can be reduced even if the spalling is prevented at a high temperature. Therefore, in this study, we measured internal temperature history and residual compressive strength using a 300×300×450mm short column specimens which use the fiber(NY 0.15+PP 0.10+SF 0.30vol·%) and respectively silica sand, washed sand, the slag sand. As a result, the temperature history and residual compressive strength are almost similar regardless of the fine aggregate types.

  • PDF

압축강도 및 가열속도에 따른 콘크리트의 폭렬성상 (Spalling of Concrete with Compressive strength and heating rates)

  • 최경철;김규용;윤민호;이영욱;황의철;이보경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2015
  • In this study, spalling property were evaluated from concrete with compressive strengths of 30MPa, 90MPa, 180MPa, applied with fast heating condition(ISO-834 standard heating curve) and slow heatign condition(1℃/min). As a result, the spalling property of concrete was shown differently with compressive and heatign rate. And It could be separated three as non spalling, surface spalling and explosive spalling.

  • PDF

화재피해를 입은 RC 슬래브의 재하실험에 관한 연구 (A Study on the loading test for of slab by Fire damaged)

  • 이규민;강승구;김동준;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

서점의 적재가연물의 연소특성에 관한 실험적 연구 (Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.47-53
    • /
    • 2011
  • 건축물 적재가연물은 종류 및 양 등의 특성에 따라 화재지속시간과 화재규모 등에 크게 기여한다. 서점은 다른 건축용도보다 가연물이 다량 적재되어 있으므로 화재발생시 화재위험성이 클 가능성이 있다. 그러나 한편으로는 서점 내부의 서적은 연소하면 탄화층이 형성되고 적재가연물량에 비해 노출표면적이 작기 때문에 화재시 열분해가스의 생성이 작을 가능성도 있다. 이러한 가능성을 다양한 실험을 통해 파악하여 서점의 화재안전설계에 합리적으로 반영할 필요가 있다. 따라서 본 연구에서는 서점의 성능위주설계에 활용하기 위하여 적재가연물을 재현한 시험체를 가열로에 넣고 ISO834-1:1999 표준가열곡선에 따라 가열하는 일련의 실험을 실행하였다. 이 실험 결과를 바탕으로 서점의 적재가연물의 연소발열성상을 파악하고 성능위주설계에 필요한 연소속도 및 열방출률 등을 제시하였다.

Behaviour of ultra-high strength concrete encased steel columns subject to ISO-834 fire

  • Du, Yong;Zhou, Huikai;Jiang, Jian;Liew, J.Y. Richard
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.121-139
    • /
    • 2021
  • Ultra-high strength concrete (UHSC) encased steel columns are receiving growing interest in high-rise buildings owing to their economic and architectural advantages. However, UHSC encased steel columns are not covered by the modern fire safety design code. A total of 14 fire tests are conducted on UHSC (120 MPa) encased steel columns under constant axial loads and exposed to ISO-834 standard fire. The effect of load ratio, slenderness, stirrup spacing, cross-section size and concrete cover to core steel on the fire resistance and failure mode of the specimens are investigated. The applicability of the tabulated method in EC4 (EN 1994-1-2-2005) and regression formula in Chinese code (DBJ/T 15-81-2011) to fire resistance of UHSC encased steel columns are checked. Generally, the test results reveal that the vertical displacement-heating time curves can be divided into two phases, i.e. thermal expansion and shortening to failure. It is found that the fire resistance of column specimens increases with the increase of the cross-section size and concrete cover to core steel, but decreases with the increase of the load ratio and slenderness. The EC4 method overestimates the fire resistance up to 186% (220 min), while the Chinese code underestimates it down to 49%. The Chinese code has a better agreement than EC4 with the test results since the former considers the effect of the load ratio, slenderness, cross section size directly in its empirical formula. To estimate the fire resistance precisely can improve the economy of structural fire design of ultra-high strength concrete encased steel columns.

도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구 (A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire)

  • 박경훈;김흥열;유용호;이철호;김형준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

가열 속도에 따른 콘크리트의 폭렬 특성 및 내부 수증기압력 평가 (Evaluation of Spalling Property and Water Vapor Pressure of Concrete with Heating Rate)

  • 최경철;이태규;남정수;박병근;김규용
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.605-612
    • /
    • 2012
  • 콘크리트의 폭렬 발생 메커니즘에 대해서는 수증기압력에 의한 파괴, 내 외부의 온도 차이에 의해 발생하는 표면 압축력에 의한 파괴, 앞선 두 가지 요인의 복합작용에 의한 파괴가 있다. 이러한 폭렬에 영향을 주는 요인은 콘크리트 자체의 재료적 특성과 관계된 내부 요인과 환경에 의한 외부 요인으로 나눌 수 있으며 폭렬 현상을 이해하기 위해서는 두 가지 요인에 대한 충분한 고려가 필요하다. 외부 환경의 요소로써 가열 속도가 다른 경우 콘크리트 내부의 수분응집 및 수증기압력의 거동이 달라질 것으로 판단된다. 따라서 이 연구에서는 30, 50, 70, 90, 110 MPa의 다양한 강도 영역의 콘크리트를 대상으로 ISO-834 표준가열곡선과 $1^{\circ}C/min$의 가열 속도를 적용하여 가열 속도에 따른 콘크리트의 폭렬 성상 및 수증기압력, 열팽창 변형을 평가하였다. 실험 결과 콘크리트의 폭렬은 급속 가열조건에서 발생하며, 콘크리트가 고강도화될수록 폭렬에 의한 단면손실량이 증가하였다. 또한, 가열 초기에 콘크리트 표면부의 수증기압력 상승 속도 및 가열 속도에 따른 열팽창에 의한 초기압력 상쇄효과가 콘크리트의 폭렬 발생에 중요한 영향을 미치는 것으로 나타났다.

반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가 (Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels)

  • 정철헌;임초롱;김현준;주상훈
    • 대한토목학회논문집
    • /
    • 제30권4A호
    • /
    • pp.391-398
    • /
    • 2010
  • 본 연구에서는 반단면 프리캐스트 패널을 갖는 RC 슬래브에 대해서 비재하 상태에서 ISO-834 화재곡선을 적용한 가열시험을 수행하였다. 가열시험시 PP섬유 혼입되지 않은 실험체에서는 콘크리트의 폭렬이 발생되고, PP섬유가 혼입된 실험체에서는 폭렬이 발생되지 않았다. PP섬유가 혼입된 반단면 프리캐스트 패널을 적용한 RC 슬래브의 발생온도는 PP섬유가 혼입되지 않은 경우보다 낮은 수준을 보였다. 화재 가열실험 후 상온상태로 냉각된 RC 슬래브의 극한하중을 평가하기 위하여 3점 휨실험을 수행하였다. 실험결과, PP섬유가 혼입되지 않은 RC 슬래브는 PP섬유가 혼입된 실험체와 비교해 약 32.5% 정도 극한하중이 감소하는 결과를 보였다. 또한, PP섬유가 혼입된 반단면 프리캐스트 패널을 갖는 RC 슬래브의 극한하중은 PP섬유가 혼입된 전두께 RC 슬래브보다 큰 수준을 보였다. 이상의 결과에서 PP섬유의 혼입과 반단면 프리캐스트 패널 적용시 화재에 대한 저항능력이 향상됨을 확인하였다.