• Title/Summary/Keyword: ISO규격

Search Result 449, Processing Time 0.025 seconds

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

Blood Pressure Cuff Bladders Tailored For Koreans (한국인 맞춤형 혈압계 커프 블래더)

  • Hwang, Lark Hoon;Park, Woo Sung;Na, Seung Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.822-829
    • /
    • 2013
  • Hypertension is one of the most common clinical diseases, with an increasing prevalence globally. Hypertension triggers various harmful consequences and affects multiple organs. Life-long care may be required in some cases. According to the Korea Center for Disease Control and Prevention, the prevalence of hypertension is gradually increasing. A 2011 survey revealed that 28.9% of Korean adults had hypertension. The prevalence rates were slightly higher among men than women. Accurate measurement of blood pressure(BP) is crucial to classify patients, to identify BP-related risks, and to inform correct treatment. For accurate blood pressure measurement, the use of a cuff bladder size appropriate for the mid-upper arm circumference(MUAC) is essential. Incorrect sized cuff bladder is one of the main causes of equipment error affecting sphygmomanometer accuracy. When commercial sphygmomanometers were examined, the cuff bladders differed from the dimensions specified in the ISO 81060-1:2007 standards. Undercuffing is responsible for a spurious overestimation of BP in patients with large arms leading to overdiagnosis of hypertension, whereas overcuffing (that is, use of relatively large cuffs with small arms), may be responsible for an opposite problem, leading to erroneous underestimation of BP levels. The cuff bladder sizes recommended by the American Heart Association(AHA) are an arm circumference(AC) of 17-25 cm for small-sized adults, AC of 24-32 cm for adults, AC of 32-42 cm for normal-sized adults, and AC of 42-50 cm for obese adults. In contrast, the AC of Korean adults ranges from 23-31 cm, belonging to a single type of adult bladder. Three types of bladders are necessary for Korean adults with an AC of 23-31cm. Hospitals often use one or two differently-sized Western cuffs for adult patients, which can yield inaccurate BP determinations. Cuff bladders with dimensions based on anthropometric reference data obtained from Koreans will aid hospitals to measure BP more accurately.

A Study on the Establishment Case of Technical Standard for Electronic Record Information Package (전자문서 정보패키지 구축 사례 연구 - '공인전자문서보관소 전자문서 정보패키지 기술규격 개발 연구'를 중심으로-)

  • Kim, Sung-Kyum
    • The Korean Journal of Archival Studies
    • /
    • no.16
    • /
    • pp.97-146
    • /
    • 2007
  • Those days when people used paper to make up and manage all kinds of documents in the process of their jobs are gone now. Today electronic types of documents have replaced paper. Unlike paper documents, electronic ones contribute to the maximum job efficiency with their convenience in production and storage. But they too have some disadvantages; it's difficult to distinguish originals and copies like paper documents; it's not easy to examine if there is a change or damage to the documents; they are also prone to alteration and damage by the external influences in the electronic environment; and electronic documents require enormous amounts of workforce and costs for immediate measures to be taken according to the changes to the S/W and H/W environment. Despite all those weaknesses, however, electronic documents increasingly account for more percentage in the current job environment thanks to their job convenience and efficiency of production costs. Both the government and private sector have made efforts to come up with plans to maximize their advantages and minimize their risks at the same time. One of the methods is the Authorized Retention Center which is described in the study. There are a couple of prerequisites for its smooth operation; they should guarantee the legal validity of electronic documents in the administrative aspects and first secure the reliability and authenticity of electronic documents in the technological aspects. Responding to those needs, the Ministry of Commerce, Industry and Energy and the Korea Institute for Electronic Commerce, which were the two main bodies to drive the Authorized Retention Center project, revised the Electronic Commerce Act and supplemented the provisions to guarantee the legal validity of electronic documents in 2005 and conducted researches on the ways to preserve electronic documents for a long term and secure their reliability, which had been demanded by the users of the center, in 2006. In an attempt to fulfill those goals of the Authorized Retention Center, this study researched technical standard for electronic record information package of the center and applied the ISO 14721 information package model that's the standard for the long-term preservation of digital data. It also suggested a process to produce and manage information package so that there would be the SIP, AIP and DIP metadata features for the production, preservation, and utilization by users points of electronic documents and they could be implemented according to the center's policies. Based on the previous study, the study introduced the flow charts among the production and progress process, application methods and packages of technical standard for electronic record information package at the center and suggested some issues that should be consistently researched in the field of records management based on the results.

MICROLEAKAGE OF THE CLASS V CAVITY ACCORDING TO RESTORATION SITE AND CAVITY SIZE USING SEM AND THREE-DIMENSIONAL RECONSTRUCTION TECHNIQUES (SEM과 3차원 재구성법을 이용한 수복면의 위치와 와동 크기에 따른 미세누출도 분석)

  • Yang, In-Seo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.112-120
    • /
    • 2005
  • This study was done to evaluate whether there were any differences in microleakage of class V composite restorations according to restoration site and cavity size. Total sixty-four restorations were made in molar teeth using Esthet-X. Small ($2\;{\times}\;2\;{\times}\;1.5\;mm$) and large ($4{\times}2{\times}1.5\;mm$) restorations were made at the buccal/lingual surface and the proximal surface each. After 1,000 times of thermocycling ($5^{\circ}\;-\;55^{\circ}C$), resin replica was made and the percentage of marginal gap to the whole periphery of the restoration was estimated from SEM evaluation. Thermocycled tooth was dye penetrated with $50\%$ silver nitrate solution. After imbedding in an auto-curing resin, it was serially ground with a thickness of 0.25 mm. Volumetric microleakage was estimated after reconstructing three dimensionally. Two-way ANOVA and independent T-test for dye volume, Mann-Whitney U test for the percentage of marginal gap, Spearman's rho test for the relationship between two techniques were used, The results were as follows : 1. The site and size of the restoration affected on the microleakage of restoration. Namely, much more leakage was seen in the proximal and the large restorations rather than the buccal/lingual and the small restorations. 2. Close relationship was found between two techniques (Correlation coefficient = 0.614/ P = 0.000). Within the limits of this study, it was noted that proximal and the large restorations leaked more than buccal/lingual and the small restorations. Therefore, it should be strictly recommended large exposure of margins should be avoided by reducing unnecessary tooth reduction.

Methodological Issues in Socio-Economic Assessment of the Hydrogen Economy Development (수소경제로 이행을 위한 사회경제적 영향평가 방법론)

  • Kim, Ho-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-591
    • /
    • 2005
  • 우리나라는 에너지의 안정적 공급과 에너지이용 과정에서 발생하는 환경적, 안보적 외부성을 최소화하는 에너지수급 구조를 마련하기 위해 2003년 12월 '제2차 신재생에너지 기술개발 및 이용보급 기본계획(2003-2012)'을 발표하였다. 이 계획에서는 2011년까지 전체 TPES의 $5\%$를 신재생에너지로 공급하는 것을 정책목표로 수립하고 수소, 태양광 그리고 풍력기술을 중점적으로 추진하기로 하였다. 특히 수소부문에서는 주택 및 건물용, 발전용, 수송용 연료전지의 개발을 중심으로 개발하여 세계 기술시장의 $20\%$를 확보한다는 계획을 발표하였다. 이러한 기술 잠재력을 기반으로 우리 정부도 미국이나 일본과 같이 수소경제로의 전환을 준비하고 있으며 2020년대 이후 우리나라의 에너지부문은 새로운 국면에 접어들 것으로 전망된다. 에너지나 환경기술의 효과적 인 개발을 위해서는 이들 기술의 직접적인 비용측면에 대한 분석 즉 경제성 평가와 새로운 기술변화로 인한 중장기적인 사회경제적 영향평가가 선행되어야 한다. 이러한 평가는 대상 기술의 사회경제적 파급효과가 광범위할수록 더욱 복잡한 분석이 요구된다. 본 연구의 주제인 수소에너지기술은 지금까지 이용되던 것과는 전혀 새로운 에너지캐리어(carrier)를 개발하는 것으로 에너지부문 및 여타 다른 산업부문이 공유하고 있는 에너지 관련 인프라의 전면적인 조정이 요구되며 에너지 이용과 관련된 사회경제적 측면의 급속한 변화를 수반한다. 본 연구는 수소경제로의 이행에 대한 사회경제적 영향평가의 방법론적 요소들과 기법을 제시한다."중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.의하게 가장 낮은 정지. 운동 마찰력을 보였고 브라켓-호선 각도가 증가함에 따라 유의하게 정지, 운동 마찰력도 증가하였다 (P<0.001)%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해

  • PDF

International Tendencies for Estavlishing a Microbiogical Standard for Food (식품의 미생물 규격기준의 국제적동향)

  • 신광순
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.77-95
    • /
    • 1986
  • In 1962 the governing bodies of FAO and WHO approved the establishment of a joint FAO/WHO Food Standards Programme, the creation of a jointly sponsored body to be known as the Codex Alimentarius commission to implement the Programme. It can reasonably be claimed that the Commission has assumad the leading role in establishing internation food standards throughout the world. The Codex Committee of Food Hygiene has received much advice and assistance from other international organization which have been working in this field for a number of years. In particular, it has received valuable background documentation from the International Commission on Microbiological Specifications for Foods(ICMSF) which was set up by the International Association of Microbiological Societies(IAMS), and also from the International Organization for Standardization (ISO). Nevertheless, in spite of the information supplied by governments and research bodies in this field, microbiological standards have proved to be a highly controversial subject from the point of view of Codex standards. When it is decided to establish a microbiological standard for a food or class of foods, the following technical and administrative aspects must be considered: 1) The standard should be based on factual studies and serve one or more of the following objectives: (1) to determine the conditions of hygiene under which the food should be manufactured; (2) to minimize the hazards to public health; (3) to measure the keeping quality and storage potential of the food 2) The standard should be attainable under practicable operating and commercial conditions and should not entail the use of excessive heat treatment or the additions of extra preservatives. 3) The standard should be determined after investigation of the processing operation. 4) The standard should be as simple and inexpensive to administer as possible, the number of tests being kept to a minimum. 5) Details of methods to be used for sampling, examining and reporting should accompany all published microbiological standards. 6) In establishing tolerance levels for the permissible number of defective samples, allowance should be made for sampling and other variations due to differences in the laboratory methods. The following additional points should be kept in mind: 1) It is not satisfactory to establish one set of microbiological standards for a miscellaneous group of foods, such as“frozen foods”or“precooked foods”. 2) Microbiological standards should be applied first to the more hazardous types of food on the basis of experience of expected microbiological levels, taking into account variations in composition, processing procedures, and storage. 3) When a standard is established, there should be a definite relationship between the standard and the hazard against which it is meant to protect the public. 4) The sensitivity, reliability, and reproducibility of the sampling and analytical methods should be compared in different laboratories and the methods to be used should be specified in detail as part of the standard. 5) Tolerances should be included in the standard to account for inaccuracies of sampling and analysis. 6) Standards should be applied on a voluntary basis before compliance is made mandatory.

  • PDF

Influence of Low Temperature Degradation on Bond Strength of Yttria-Stabilized Tetragonal Zirconia Polycrystal Core to Veneering Ceramic (저온열화현상이 지르코니아 코어와 전장도재의 전단결합강도에 미치는 영향)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • The purpose of this study was to evaluate the influence of low temperature degradation (LTD) on the bonding strength of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP). The push-shear bond test method was used to investigate the core-veneer bonding strength of industrially manufactured Y-TZP core ceramic and manufacturer recommended veneering ceramic. Four groups from ceramic-zirconia specimens (n=28; n=7 per group) were assigned into four experimental aging conditions, namely storage in an autoclave at $134^{\circ}C$ for 0, 3, 5, 10 hours. Bonding strength was obtained using a universal testing machine with crosshead speed 0.5 mm/min. Data were statistically analyzed using one-way ANOVA and Tukey's test (${\alpha}=0.05$). In bonding strength test, the group which was treated with LTD showed lower bonding strength than no treated group. The ceramic-zirconia bonding strength was affected by LTD (p<0.05). Digital microscope examination of the fracture surface showed mixed failures with adhesive and cohesive types in LTD with treated Y-TZP groups.

Reference System for LBS supported Location Based Value added Service (위치기반 응용 서비스(항법, 디렉토리, 위치추적)를 지원하는 LBS 표준 참조 시스템)

  • Lee, Nack-Hun;Park, Joo-Hoon;Ahn, Byung-Ik
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.33-38
    • /
    • 2004
  • 최근 들어 무선인터넷 및 모바일 컴퓨팅 기술의 급속한 발전과 함께 향후 그 수요가 증대될 것으로 예상되는 분야가 위치기반 서비스(LBS: Location Based Service) 기술이다. 위치기반 서비스는 이동 중인 사용자의 위치정보를 여러 가지 부가 서비스와 결합시켜 다양한 서비스를 제공하는 것으로 휴대 단말기와 무선 네트워크, 위치 측위 기술, 각종 응용 어플리케이션 등이 총체적으로 합쳐져 제공되는 서비스로 이동성, 개인성, 적시성 등을 사용자에게 제공해 주는 GIS의 차세대 핵심기술로 발전이 예상되는 분야이다[2][3]. 현재 미국, 유럽 등을 중심으로 3GPP/3GPP2, OMA, OGC, ISO, MAGIC 등의 국제 표준화 기구 및 단체에서 위치기반 서비스에 대한 표준화가 활발히 진행되고 있으며, 국내에서도 그 중요성을 인지하고 LBS 표준화에 정보, 업체, 학계 및 연구기관의 LBS 관련 전문가들로 구성된 LBS 표준화 포럼을 중심으로 국내 LBS 기술 표준을 위한 연구가 활발하게 진행되고 있다. 본 연구에서는 국내 LBS 표준들을 기반으로 위치기반 서비스에서 가장 기본적이고 핵심이 되는 서비스를 제공하는 표준 참조 시스템을 개발하고자 한다. 개발하고자 하는 표준 참조 시스템은 사용자의 위치를 추적하고 확인할 수 있는 위치추적 서비스와 주변 시설물 검색을 위한 디렉토리 서비스, 목적지까지의 경로를 안내하는 항법 서비스를 위한 기능 인터페이스 표준을 제공한다. 위치기반 서비스를 위한 표준 창조 시스템은 위치기반 응용 서비스의 기능 규격과 표준 인터페이스를 제공함으로써 위치기반 서비스 및 시스템 개발의 중복을 방지하고 상호 호환성을 확보 할 수 있다.문제에 적용이 가능한 창조 모델로 이용될 수 있을 것으로 생각된다.}94,\;29.4{\pm}30.3,\;45.1{\pm}44$로 Mel 10군과 Mel 30군이 유의적인 감소를 보였으나(p<0.05) 이들 두 군 간의 차이는 나타나지 않았다. 이상의 결과로, 랫트에서 복강수술 후 melatonin 10mg/kg투여가 복강 내 유착 방지에 효과적이라고 생각된다.-1}{\cdot}yr^{-1}$로서 두 생태계에 축적되었다.여한 3,5,7군에서 PUFA 함량이 증가한 반면, SFA 함량은 감소하여 P/S 비율, n-3P/n-6P 비율은 증가하는 경향이었으며 이는 간장의 인지질, 콜레스테롤 에스테르, 총 지질의 지방산조성에서도 같은 경향을 볼 수 있었다.X>$(C_{18:2})$와 n-3계 linolenic acid$(C_{18:3})$가 대부분을 차지하였다. 야생 돌복숭아 과육 중의 지방산 조성은 포화지방산이 16.74%, 단불포화지방산 17.51% 및 다불포화지방산이 65.73%의 함유 비율을 보였는데, 이 중 다불포화지방산인 n-6계 linoleic acid$(C_{18:2})$와 n-3계 linolenic acid$(C_{18:3})$가 지질 구성 총 지방산의 대부분을 차지하는 함유 비율을 나타내었다.했다. 하강하는 약 4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하

  • PDF

Influence of Dissolved Gases on Crystal Structure of Electrodeposition Films Containing Calcium and Magnesium in Seawater (해수 중 칼슘 및 마그네슘을 포함한 전착 코팅막의 결정구조에 미치는 용해 기체의 영향)

  • Park, Jun-Mu;Seo, Beom-Deok;Lee, Seul-Gi;Kim, Gyeong-Pil;Gang, Jun;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.116-116
    • /
    • 2018
  • 부식은 재료와 사용 환경과의 상호작용에 의한 결과로서 일반적으로 두께의 감소와 균열의 발생 및 파손 등의 문제로 나타난다. 특히 사용환경 중에서 해수 분위기는 금속의 부식에 가장 유리한 조건이다. 따라서 해양환경 중 항만이나 조선 및 해양 산업 등에 많이 이용되는 강 구조물은 이에 대응하기 위하여 도장방식이나 음극방식을 사용하고 있다. 여기서 음극방식은 피방식체를 일정전위로 음극 분극하는 원리로써 외부전원을 인가하거나 비전위의 금속을 전기적으로 연결하여 방식하는 방법이다[1]. 한편, 해수 중에서 이와 같은 원리로 음극방식 할 경우에는 피방식체인 강재표면에 부분적으로 칼슘 또는 마그네슘 화합물 등의 생성물이 부착하는 현상을 볼 수 있게 된다. 이와 같이 수산화마그네슘($Mg(OH)_2$)및 탄산칼슘($CaCO_3$)을 주성분으로 하여 석출되는 석회질 피막(calcareous deposits)은 피방식체에 유입되는 음극방식 전류밀도를 감소시켜 주거나 물리적 장벽의 역할을 함으로써 외부의 산소와 물 등 부식환경으로부터 소지금속을 보호한다[2]. 그러나 석회질 피막은 소지금속과의 결합력, 막의 균일한 분포, 내식성 및 제작시간의 단축 등 해결해야 할 과제가 있다. 또한 여러 가지 환경 조건 등의 영향을 받아 그 피막의 형성 정도도 가늠하기 어렵기 때문에 음극방식 설계 시 그 정도에 따른 영향을 고려-반영하기가 곤란하다. 따라서 본 연구에서는 석출속도, 밀착성 및 내식특성을 향상시키기 위해 전착프로세스를 통해 해수 중 기체를 용해시켜 석회질 피막을 제작하고 막의 결정구조 제어 및 특성을 분석-평가하였다. 본 연구에 사용된 강 기판(Steel Substrate)은 일반구조용강(KS D 3503, SS400)을 사용하였으며, 외부전원은 정류기(Rectifier, xantrex, XDL 35-5T)를 사용하여 3 및 $5A/m^2$의 조건으로 인가하였다. 양극의 경우에는 해수에 녹아있는 이온 이외에 다른 성분들이 환원되는 것을 방지하기 위해 불용성 양극인 탄소봉(Carbon Rod)을 사용하였다. 이때 석출속도, 밀착성 및 내식특성 향상을 위해 해수에 주입한 기체의 양은 0.5 NL/min였으며, 기판 근처에 고정하여 음극 부근에서의 반응을 유도하였다. 각 조건별로 제작된 막의 표면 모폴로지, 조성원소 및 결정구조 분석을 실시하였으며, 석회질 피막의 밀착성과 내식특성을 평가하기 위해 규격에 따른 테이핑 테스트(Taping Test, ISO 2409)와 3 % NaCl 용액에서 전기화학적 양극 분극 시험을 진행하여 제작된 막의 내구성과 내식성을 분석-평가하였다. 시간에 따른 전착막의 외관관찰 결과 전류밀도의 증가와 함께 상대적으로 많은 피막이 형성되었고, 용해시킨 기체에 의해 더 치밀하고 두터운 피막이 형성됨을 확인할 수 있었다. 성분 및 결정구조 분석 결과 $Mg(OH)_2$ 성분의 Brucite 및 $CaCO_3$ 성분의 Calcite 및 Aragonite 구조를 확인하였으며, 용해시킨 기체의 영향으로 $CaCO_3$ 성분의 Aragonite 구조가 상대적으로 많이 검출되었다. 밀착성 및 내식성 평가를 실시한 결과 해수 중 용해시킨 기체에 의해 제작한 시편의 경우 견고하고 화학적 친화력이 높은 Aragonite 결정이 표면을 치밀하게 덮어 전해질로부터 산소와 물의 침입을 차단하는 역할을 하여 기체를 용해시키지 않은 3 및 $5A/m^2$ 보다 비교적 우수한 밀착성 및 내식 특성을 보이는 것으로 사료된다.

  • PDF

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.