• Title/Summary/Keyword: ISO/IEEE 11073 PHD

Search Result 17, Processing Time 0.021 seconds

Design of an $SpO_2$ Transmission Agent based on ISO/IEEE 11073 Standard Protocol (ISO/IEEE 11073 표준 프로토콜 기반의 산소포화도 전송 에이전트 설계)

  • Pak, Ju-Geon;Im, Sung-Hyun;Park, Kee-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.462-465
    • /
    • 2011
  • A pulse oximeter is a device which provides non-invasive estimate of percentage oxygen saturation of haemoglobin (SpO2). Due to the limitations of resources of personal health devices (PHDs) including pulse oximeters, they generally transmit the estimated data to a remote monitoring server through a close manager (e.g. mobile device or PC). Therefore, communication protocols between PHDs and a manager is an important research topic in terms of interoperability. In this paper, we present design results of an SpO2 transmission agent based on the ISO/IEEE 11073 (X73) protocol. The protocol is an international standard for PHDs. The agent is an embedded program which generates X73 messages from the estimated pulse rates and SpO2, and transmits the messages to a close manager. The agent consists of a Session, Message and Memory Handler. The Session Handler manages a communication session with the manager, and the Message Handler generates and analyzes the exchanged messages according to the X73 protocol. The Memory Handler extracts pulse rates and SpO2s which are stored in a memory of the pulse oximeter. The SpO2 transmission agent allows pulse oximeters to communicate with managers based on x73 standard. Consequently, the interoperability between the pulse oximeters and the managers is guaranteed.

  • PDF

Design of PHD(Personal Health Device) Monitoring Application based on Bluetooth HDP(Health Device Profiles) (Bluetooth HDP 기반 개인건강기기 모니터링 애플리케이션 시스템 설계)

  • Chio, Chi-man;Kang, Sung-in;Kim, Gwan-hyung;Choi, Sung-wook;Kim, Jong-Pan;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.954-956
    • /
    • 2013
  • IOS/IEEE 11073 PHD 표준들은 u-헬스 측정기기와 u-헬스 게이트웨이간의 통신을 가능하게 하도록 설계되어 있다. 모바일 단말기를 데이터 취합을 위한 중계기로 활용하고 별도의 게이트웨이를 구성하여 헬스케어 의료기기를 연동하고 모니터링을 위한 인터페이스를 제공해 왔으나 스마트폰 애플리케이션 단계에서 IEEE 11073 플랫폼을 포함하여 헬스케어 의료기기를 활용하는 u-헬스케어 서비스를 제공하기에는 많은 제약이 있다. 이에 본 논문에서는 Android 4.0.x OS 스마트폰을 대상으로 Bluetooth HDP을 활용하여 u-헬스케어 시스템에서의 게이트웨이/서버 플랫폼 기능을 포함하는 헬스케어 의료기기의 모니터링 애플리케이션 시스템을 설계하였다.

  • PDF

Design of Smart TV-based Integrated Gateway Solution for Wellness Service (웰니스 서비스를 위한 스마트 TV 기반 통합 게이트웨이 솔루션 설계)

  • Kim, Jong-Pan;Heo, Sung-uk;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.950-953
    • /
    • 2013
  • 본 논문은 헬스케어 서비스에 대한 소비자 인식의 변화에 따라 최근 대두되고 있는 웰니스 서비스에 관한 연구이다. 현재 많은 소비자들이 여러 가지의 홈 헬스케어 개인건강기기를 통해 자신의 건강을 관리하고 있지만 제조사 별 고유의 소프트웨어와 통신 프로토콜을 내장되어있어 개인건강기기마다 각기 다른 방식의 서비스가 제공되고 있다. 이처럼 현재 제공되고 있는 헬스케어 서비스를 보다 효율적으로 제공하기 위해서는 다양한 개인건강기기와 서비스 제공 시스템간의 표준화된 인터페이스를 지원하기 위해서는 통합 게이트웨이 솔루션이 필요하다. 특히, 각 시스템 구성요소 간에 IEEE11073 PHD(Pelsonal Health Devices), HL7(Health Level Seven) 등의 표준을 통하여 건강정보 데이터 센싱, 취합 및 전송, 분석 및 피드백이 표준적인 방법으로 운용되어야한다. 이에 본 논문에서는 스마트 TV 환경에서 ISO/IEEE11073 표준을 준용하여 다양한 통신 인터페이스를 통한 개인건강기기의 연결성을 지원하는 통합 게이트웨이 솔루션 및 헬스케어, 건강관리와 관련된 서비스를 위한 건강정보 모니터링 앱을 설계하였다.

  • PDF

A Research and development of healthcare gateway for international standards that support a WiBro / WiMAX (WiBro/WiMAX 지원 국제표준 헬스케어 게이트웨이 연구 개발)

  • Lee, Jeong-Gi;Kim, Kuk-Se;Kim, Choong-Won;Ahn, Seong-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.3020-3028
    • /
    • 2014
  • In the present study, A protocol gateway between agent is designed by using an optimized protocol for the exchange of ISO / IEEE 11073-20601 in order to compensate the disadvantage of the existing gateway and a international standard healthcare set-top. The gate way was designed to smooth data transmission to overcoming the geographical limits of the service and to enable data transfer on emergency vehicle and the mountain area.

u-Healthcare Monitoring System Design using by Smartphone base on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-lae;Kim, Sang-yoon;Kim, Jung-han;Oh, Am-Suk;Jean, Jae Hwan;Kang, Sung-in
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.392-394
    • /
    • 2013
  • 최근 u-Healthcare 서비스에서 다양한 생체정보를 간편하게 측정하는 개인건강기기(PHD)와 측정된 정보를 전송하고 수집하기 위한 표준의 필요성이 제품 간의 이식성, 확장성, 상호 운영성을 보장하기 위해 크게 대두되고 있다. 개인건강기기에서 측정된 생체정보(산소포화도, 몸무게, 심전도, 혈압 등)를 ISO/IEEE 11073 기반인 Bluetooth Health Device Profile을 이용해서 스마트폰으로 실시간 모니터링 할 수 있는 시스템을 설계한다.

  • PDF

IEEE 11073/ISO TC215 국제 표준기반 유헬스 플랫폼 기술

  • Im, Jun-Ho;Park, Chan-Yong;Park, Su-Jun
    • Information and Communications Magazine
    • /
    • v.27 no.9
    • /
    • pp.15-22
    • /
    • 2010
  • 세계 최고로 예상되는 급속한 인구구조의 고령화로 향후 우리나라는 보건, 의료, 복지 등에서 심각한 사회 문제에 직면할 것으로 예상되고, 고령화 사회로 인한 만성질환 증가는 의료비 증가로 이어져 국가 재정에 대한 부담으로 작용할 것이다. 정보통신기술을 이용하여 시간과 공간에 구애 받지 않고 언제 어디서나 건강과 생활을 관리하여 건강한 삶을 유지시키는 새로운 형태의 서비스인 유헬스(ubiquitous-Health)가 주목을 받고 있다. 일반인, 고령자, 만성질환자를 대상으로 하는 유헬스용 개인 건강 기기의 개발은 기존의 제품에서 네트워크와 연동이 되는 제품으로 보급되고 있으나, 데이터 상호 운용성이 고려되지 않은 제품이 주류를 이루고 있어 향후 진정한 유비쿼터스 개념의 건강관리를 위한 서비스를 실현하는데 문제가 될 것으로 예상되고 있다. 유헬스 기술이 표준화 되면, 생체정보 데이터의 취합 및 전송, 분석 및 피드백이 표준적인 방법으로 운용이 될 수 있으므로, 개인 건강 기기들과, 이들을 처리하는 유헬스 서비스간의 상호 운용성이 보장이 된다. 본 고에서는 최근 유헬스 분야에서 가장 활발한 표준화가 진행중인 IEEE 11073 PHD 표준화 동향에 대해서 살펴보고, 본 연구원에서 개발한 국제 표준기반 유헬스 플랫폼에 대한 소개를 한다.

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.