The Application and Evaluation of Atmospheric Dispersion Models in Pusan Area - Based on TCM2, CDM2.0, ISCLT2 - (부산지역에서의 대기확산모델의 적용 및 평가 -TCM2, CDM2.0, ISCLT2 모델을 중심으로)

  • 방종선;김유근
    • Journal of Environmental Science International
    • /
    • v.5 no.6
    • /
    • pp.699-712
    • /
    • 1996
  • For the efficient control of atmospheric quality, it is so important to predict the influence accurately of which the air pollutant emitted into the atmosphere. Atmospheric dispersion model enables to simulate and grasp the atmospheric condition occurred due to the emission of pollutants. The result of model is largely affected by the amount of emission, the characteristics of physical and chemical process, meteorological input data, and the receptor which the concentration is calculated. The aim of this research, therefore, is to suggest more suitable model in Pusan area than other areas by performing TCM2, CDM2.0 and ISCLT2 models. As the basic work for executing the model, we computed the amount of emission of air pollutants in Pusan at 1992 and analyzed the occurrence frequency of atmospheric stability for recent decade(1985~19941, CDM2.0 showed the similar result relatively with observed value in the case of full year(1992), fall and winter, and ISCLT2 brought more suitable result in spring for Pusan area. As the result of this research, in future, it is necessary for us to develop the numerical model considering the topographical characteristics, to select the proper observation site and to increase the observation site for Pusan.

  • PDF

Estimation of Fluxes of Air Pollutants in Seoul Conurbation Using ISCLT3 (ISCLT3를 이용한 수도권 도시간 대기오염물질 유출입량 추정)

  • 홍민선;김순태;김영제;양소희;이동섭;장영기
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.147-155
    • /
    • 2001
  • ISCLT3 model was applied in Seoul metropolitan area to investigate the source-receptor relationships among 17 cities in the Kyonggi Province. For the purpose of the model simulation, emission rates of NO$_2$, SOx, and PM(sub)10 were prepared for grid scale with 1$\times$1 km, and receptors were located on every 2$\times$2 km grid. Meterological data for the last 10 years(88~97) were used as input data. According to our study, NO$_2$ concentration of the cities ranged from 10 to 45 ppb with the highest value appearing from Puchon city. The concentrations of SOx and PM(sub)10 concentrations fell in the range of 5~20 ppb and 20~70$\mu\textrm{g}$/㎥, respectively. It was also found out that air quality in one city can be affected greatly by the air pollutants originating from other cities.

  • PDF

A study on the Development of TCM Urban and Rural mode for Environmental Impact Assessment (환경영향평가를 위한 도시형과 교외형 TCM 개발에 관한 연구)

  • Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.1
    • /
    • pp.63-70
    • /
    • 1998
  • TCM has been used for many environmental impact assessments in Korea. But there was reported that an error was found in area source calculation of original TCM and modified. In this study, TUM(TCM-urban mode) and TRM(TCM-rural mode) were developed for urban and rural area by modification of original TCM. McElroy-Pooler dispersion parameter was used for area and point source in TUM, Pasquill-Gifford parameter was used for area and point source in TRM. And Irwin's vertical wind speed profile exponents were used for TUM and TRM. Then predicted value by TUM, TRM and a value from the same area and point data by CDM2, ISCLT3 were compared. And it was found that predicted value from point source by TUM, TRM was very similar to a value by CDM2, ISCLT3, and predicted value from area source by TRM was similar to a value by CDM2, ISCLT3. But predicted value from area: source by TUM was an half lower than a value by CDM2, ISCLT3.

  • PDF

Modeling of SO2 Distributions in the Seoul Area by Using ISCLT (ISCLT에 의한 서울지역의 SO2 오염도 조사)

  • Ghim, Young-Sung;Son, Jae-Ek
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.128-137
    • /
    • 1992
  • Sulfur dioxide distributions in the Seoul area in 1988 were reproduced by using ISCLT which was the most versatile model among the preferred models recommended by USEPA. Modeling was performed season by season in order to take into account distinct four seasons in Korea. Predicted concentrations were close to the observed ones in most regions, but were different from the observed ones in such regions where the effect of sources outside the Seoul area was important. For better results of the modeling, the modeling domain should be chosen after a careful examination of principal wind directions.

  • PDF

Estimation of $SO_2$ Concentration in Petroleum Industrial Complex Area by ISCLT Model (ISCLT 모델을 이용한 석유화학공단지역의 $SO_2$ 농도 예측)

  • 서성규;이선원;박종혁
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.409-410
    • /
    • 1999
  • 여천산업단지는 1969년 총면적 583만평 규모로 조성되어 96년 현재 96개 업체가 입주하여 연간 생산액이 13조원에 이르는 대규모 공단으로 성장하였다(한국과학기술원, 1996). 특히, 1996년 대기보전 특별대책지역으로 지정되어 엄격한 배출기준이 적용되는 지역이며, 현재 인근지역인 광양 등을 대기환경 규제지역으로 지정하고자 논의되고 있는 실정이다.(중략)

  • PDF

Comparison of Complex Terrain Effects in the Air Dispersion Modeling at the Poryong Power Plant Site (보령화력 지역의 복잡지형이 대기확산 모델링에 미치는 영향 비교)

  • 오현선;김영성;김진영;문길주;홍욱희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.427-437
    • /
    • 1997
  • Complex terrain which is rather typical topographic character in Korea would greatly influence the dispersion of air pollutant. In this study, we investigated how the complex terrain in the vicinity of the coal-fired plant affects the air dispersion modeling results by using several US EPA models: SCREEN, CTSCREEN, ISCLT3, ISCST3, and RTDM. Screening analysis was followed by long-term analysis, and the plume movement over the terrain was precisely tracked for selected cases. Screening analysis revealed that the highest concentration of sulfur dioxide occurs at the downwind distance of 1.3 km under the unstable conditions with weak winds. However, this highest level of $SO_2$ could be raised by 4 times even in the presence of a hill of 170 m at a distance of 2 to 3 km. Seasonal and annual average concentrations predicted with the ISCLT3, ISCST3, and RTDM models showed a rapid incrase of $SO_2$ levels in front of the high mountains which are located more than 15 km away fromt the source. The highest concentrations predicted with ISCST3 were significantly higher than those with ISCLT3 and RTDM mainly because ISCST3 chooses simple-terrain model calculations for receptors between stack height and plume height. Although the highest levels under the stable conditions were usually found in the areas beyond 15 km or more, their absolute values were not so high due to enough dispersion effects between the source and the receptors.

  • PDF

大氣汚染 擴散모델 開發에 關한 硏究

  • 金良均;崔德一;李敏熙;趙康來;羅賑均;鄭長海
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.53-70
    • /
    • 1985
  • This study was performed to develop and to evaluate an air quality model for determining long-term average concentration of sulfur-dioxide for the Seoul area. CDMQC, TCM-2, and ISCLT were applied and tested in this comparison studies with same point source, area source emission data, and meteorological data to calculate seasonal concentration. Mean emission height of area sources was assumed 6m. Six different values of initial sigma Z for eah stability class were used for area sources. And decay half life was not considered in the model calculations. The results are highly correlated with measurements, the correlation coefficients of calculated and measured for CDMQC, TCM-2, and ISCLT are 0.85, 0.93, and 0.96, respectively.

  • PDF

Sensitivity of Air Pollutants Dispersion According to the Selection of Meteorological Data - Case of Seongseo Industrial Complex of Daegu - (기상자료에 따른 대기오염확산 민감도평가 -대구성서산업단지에 대한 사례연구-)

  • Park Myung-Hee;Kim Hae-Dong;Park Mi-Young
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.141-156
    • /
    • 2005
  • The importance of atmospheric conditions for the assessment of an air pollution situation has been demonstrated by their influence on the various compartments of an air pollution system, comprising all stages from emission to effects. Especially, air pollutants dispersion phenomenon are very sensitive according to wind data. But the discussions of how to apply representative meteorological data in air pollution dispersion model are not frequent in Korean environmental assessment processes. In this study, we investigated the difference of air pollutants dispersion phenomenon using U.S EPA ISCLT3 model according to applying the different meteorological data observed at two points for Seongseo industrial complex of Daegu. Two points are the spot site of Seongseo industrial complex and Daegu meteorological observatory. The winds speed of the spot site were smaller than those of Daegu meteorological observatory. In the winter season, the differences came to about $64\%$ for the period$(I\;February\;2001\~31\;January\;2002)$. Wind directions were also fairly different at two points. The air pollutants dispersion phenomenon estimated from our numerical experiments were also fairly different owing to the meteorological conditions at two points.

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.