• Title/Summary/Keyword: IR absorption

Search Result 556, Processing Time 0.031 seconds

Effect of processing Conditions on $3,400cm^{-1}$ -OH Peak in IR Transmitting Heavy Metal Fluoride Glasses (적외선 투과성 플루오르화 중금속 유리의 $3,400cm^{-1}$ -OH 흡수에 미치는 가공조건의 영향)

  • ;C. T Moynihan
    • Journal of the Korean Ceramic Society
    • /
    • v.21 no.3
    • /
    • pp.231-238
    • /
    • 1984
  • Heavy metal fluoride glasses exhibit considerable promise as high transparency materials from the UV to the IR. These glasses are prepared by fusion of the mixture of metal fulorides($ZrF_4$, $BaF_2$, $LaF_3$ etc) at 800-1, 00$0^{\circ}C$ under the inert$(N_2)$ or reactive ($CCl_4$, $Cl_2$) atmosphere following the casting into glass on cooling. Infrared absorption at the 3, 400 cm-1 -OH peak has been measured as a function of thickness for several ZrF-$BaF_2$-LaF and $HfF_4$-$BaF_2$-$LaF_3$ glasses to separate contributions from bulk and surface -OH. For glasses melted under $CCl_4$ reactive atmosphere the peak is due almost entirely to surface-OH. and melting in a closed reactor was best for removing -OH. In ambient atmosphere the -OH peak exhibited no time dependence over a 30 d period indicating a very small rate of surface attack by atmospheric H2O. Removal of -OH absorption processing was generally easier and more complete for the $BaF_2$/ThF4-glasses than for the $ZrF_4$-or $HfF_4$-based glasses.

  • PDF

Analysis of Xe Plasma by LAS (레이저 흡수법을 이용한 제논 플라즈마 분석)

  • Yang, Jong-Kyung;Her, In-Sung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.220-222
    • /
    • 2005
  • We can classify two cases in a way to observe an atom of gas state or a molecule using the laser. First case is way to use dispersion phenomenon like Rayleigh scattering, Thomson scattering, Mie scattering, Raman Scattering. And Second case is a way to use change phenomenon like a LAS (Laser Absorption Spectroscopy), LIF (Laser Induced Fluorescent). In this paper, we have measured the meta-stable density and the distribution by using a LAS method in Xe discharge lamp. The laser absorption spectroscopy (LAS) is useful to investigate the behavior of such species. The xenon atoms in the $1S_4$ and $1S_5$ generate excited $Xe^*$(147nm) and $Xe_{2}^*$(173nm) dimers in Xe plasma. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The laser is used CW laser that consist of AlGaAs semiconductor and energy level is used 823.16nm wavelength. We measured signal of monochrometer from the lamp center while will change a discharge electric current by 6mA in 3mA and calculated meta-stable state density of a xenon atom through a measured value.

  • PDF

The Adhesion Promotion of Glass Fiber Reinforced Composite Using Methacrylate Functional Silanes (메타아크릴레이트 실란을 이용한 유리섬유 강화복합재료의 물성향상)

  • Jang, Jyong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.133-139
    • /
    • 1990
  • Methacrylate functional silanes with different methylene spacer groups have been synthesized and the orientation effect and absorption behavior of these silane coupling agent were investigated by Fourier transform infrared spectroscopy(FT-IR). The mechanical properties of glass bead/polyester composites are found to be dependent on the spacer group of treated silane coupling agent. The absorption rate of the silane coupling agent onto the fumed silica surface decreases with increasing the number of the methylene spacer in methacrylate functional silanes. Silane molecules containing long spacer groups are adsorbed onto silica slightly bowed with respect to the substrate surface. The relationship between silane molecular structure and mechanical properties of polymer composites is also investigated in order to improve hot/wet properties of glass fiber/polyester composites.

  • PDF

Spectrophotometric Determination of Antihistaminics by using Iodine as Electron Acceptor (요오드를 전자수용체로 한 항히스타민제의 분광학적 분석)

  • Moon, Hong-Seob;Baik, Chai-Sun
    • YAKHAK HOEJI
    • /
    • v.33 no.3
    • /
    • pp.141-148
    • /
    • 1989
  • The weak UV absorbing antihistaminics such as chlorpheniramine, triprolidine, tripelennamine and diphenhydramine were analyzed by charge-transfer spectrophotometric method. The results obtained are summarized as folows. It was possible to determine a weak UV absorbing antihistaminics using the intense charge-transfer UV bands in chloroform. Charge transfer complexes were formed in a 1:1 ratio between antihistaminics and iodine in chloroform. Linear relationship was found between absorbance and concentration in the range of $1.0\;{\times}\;10^{-5}M-5.0\;{\times}\;10^{-5}M$ for chlorpheniramine( ${\varepsilon}\;=\;2.082\;{\times}\;10^4$) and tripelennamine ( ${\varepsilon}\;=\;1.578\;{\times}\;10^4$), $1.0\;{\times}\;10^{-5}M-8.0\;{\times}\;10^{-5}M$ for triprolidine ( ${\varepsilon}\;=\;1.120\;{\times}\;10^4$) and $1.0\;{\times}\;10^{-5}M-1.0\;{\times}\;10^{-4}M$ for diphenhydramine ( ${\varepsilon}\;=\;9.900\;{\times}\;10^3$). Charge transfer complexes of chlorpheniramine, triprolidine and tripelennamine have absorption maxima at 293 nm and complex form of diphenhydramine has absorption maximum at 270 nm. By UV, IR spectra, it could be inferred that CT-complexes were formed by interaction between the basic nitrogen of antihistaminics as electron donor (non bonding electron) and iodine as electron acceptor (${\sigma}$ bonding electron).

  • PDF

A Wearable Watch-type Reflectance-based Blood-oxygen Saturation (SpO2) Level Estimation (반사광을 이용한 손목시계형 혈중산소포화도 (SpO2) 측정기)

  • Lee, Hooseok;Thap, Tharoeun;Lee, Jinseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.578-579
    • /
    • 2015
  • Transmission and reflectance are two non-invasive techniques to perform pulse oximetry. This paper presents a design of reflectance-based pulse oximetry for watch-type wearable device, in which sensor and detector are located on the same surface of the body part. The basic principle of a pulse oximeter is based on the measurement of the red and infrared (IR) light absorption. Oxygenated blood has significant differences of light absorption characteristics than deoxygenated blood under red (660 nm) and infrared (940 nm) wavelength. Infrared is absorbed more by oxygenated hemoglobin than red. So the hardware implementation is included placing of the two LEDs (red and IR) with single photo-detector in the middle on the patient's wrist to get the corresponding pulsatile signals which are used to estimate the $SpO_2$.

Measurements of Transmittances and Calculations of Fundamental Radiative Properties (투과율의 측정 및 이를 이용한 복사물성치의 계산)

  • Hwang, Yong-Ha;Park, Seung-Ho;Lee, Young-Soo
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.29-37
    • /
    • 1994
  • Radiative charaacteristics of glass windows and porous absorbing media which can be used for a solar air heater are determined through the measurements of spectral transmittances. Those in the visible range are measured by the UV-IR spectrometer. Refractive index of glass are obtained by the comparison of the measured transmittances and the correlations derived from the electromagnetic theory and are compared to the theoretical ones calculated from the classical dispersion theory. Absorption and back-scattering coefficients of 15-mesh stainless wire screens are calcuated by the comparison of the measured transmittances and the correlations derived from the two flux model.

  • PDF

Confirming Animal Glue in Dancheong Sample by Pyrolysis/GC/MS (열분해/GC/MS에 의한 재현 단청 시편에서 아교의 확인)

  • Park, Jong Seo;Kim, Mi Jeong;Kim, Soon Kwan
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.21-32
    • /
    • 2016
  • Animal glue is a traditional material used extensively as adhesive and binder in mother-of-pearl, wooden structure, traditional painting, etc. Analysis of animal glue is usually performed with IR(infrared spectroscopy) based on the IR absorption of functional group. But, it has a limitation in confirming animal glue when a sample consists of several materials because of overlapping of the absorption band. Py/GC/MS(pyrolysis/gas chromatography/mass spectrometry) is a useful tool in analyzing the constituent of polymeric materials like animal glue by identifying their pyrolysate with very small amount of sample. In this study, confirmation of animal glue in a Dancheong sample was tried with this method. Characteristic pyrolytic compounds of animal glue and tung oil used in Dancheong were identified. Dancheong sample painted with Noerok as a coloring material, animal glue and tung oil was prepared and it was possible to find characteristic peaks of animal glue after thermal degradation and artificial weathering experiment. From this, we found that animal glue can be detected using py/GC/MS in cultural heritage samples consisting of several materials and in different condition. IR was also tried to analyze Dancheong sample and the results were compared with those of py/GC/MS for the detection of animal glue.

Surface Discharge Characteristics of Phenolic Resin Treated by Heat and Its Structure Analysis (열처리된 페놀수지 표면에서의 방전 특성과 구조분석)

  • Shong, Kil-Mok;Roh, Young-Su;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.71-79
    • /
    • 2006
  • For clearing the cause of firing due to the tacking on the surface of phenolic resin, this paper describes the analysis through a couple of methods ; FT-IR; DTA; photograph analysis, etc. Phenolic resin has been widely employed as a case of low voltage appliances. In the experiment it was confirmed that its surface was carbonized and graphitized by the external fire. In the FT-IR test a graphite specimen thermally treated at $150[^{\circ}C]$ showed the 2 different IR absorption peaks at $1,730[cm^{-1}]\;and\;1,680[cm^{-1}]$. In normal phenolic resin, the exothermic peak appeared at $450[^{\circ}C]$, while in graphite specimen, it appeared at $610[^{\circ}C]$ in DTA test. From the results, the electrical fire causes could be cleared and it is expected to protect the human life and property from the electrical fire by using the important data.

An Ultra-thin IR Cut-off Filter Based on Nanostructures (나노구조 기반 초박형 적외선 차단 필터)

  • Hyundo Yang;Jong-Kwon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.24-29
    • /
    • 2024
  • We propose a hyperbolic metastructure based on a nanopatterned metal (Ag)-dielectric (PDMS) multilayer and report on its performance in an infrared (IR) cut-off filter for imaging devices. By optimizing the size of the square-shaped Ag nanopattern and the thickness of PDMS surrounding the Ag nanopattern, the proposed IR cut-off filter blocks 99% of light in the 0.70-1.01 ㎛ wavelength band while maintaining a high transmittance of over 94% in the visible region. Here, the cut-off wavelength band starts at a region above the epsilon-near-zero wavelength of the hyperbolic metastructure and ends at the point where plasmonic absorption appears strongly. It is observed that transmittance in the wavelength region longer than the IR cut-off band increases again due to plasmonic coupling among horizontally adjacent Ag nanopatterns. This metastructure can improve the performance of IR-blocking filters as well as allow it to be manufactured ultra-thin, which is applicable to various planar optical elements and integrated optical components.

Reduced Graphene Oxide Field-Effect Transistor for Temperature and Infrared Sensing

  • Trung, Tran Quang;Tien, Nguyen Thanh;Kim, Do-Il;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.552-552
    • /
    • 2012
  • We fabricated reduced graphene oxide field-effect transistor (RGO-FET) on glass for highly sensitive temperature and IR detection. The device has the channels of RGO responsive to physical stimuli such as temperature and IR. The RGO sensing layers are fabricated from exfoliated graphene oxide sheets that are deposited to form a thin continuous network by electrostatic assembly. These graphene oxide networks are reduced toward reduce graphene oxide by exposure to a hydrazine hydrate vapor. To improve performance and eliminate interferences from oxygen and water vapor absorption to electrical properties of RGO-FET, the sensor devices were encapsulated by the tetratetracontane layer after annealing treatment. The device with encapsulation layer showed lower hysteresis, improved stability, and better repeatability. The temperature response of RGO-FET is examined by measuring changing the temperature, the device exhibited the high sensitivity and repeatability even with the temperature interval of 1 K. We also demonstrated that our devices have capability of IR sensing.

  • PDF