• Title/Summary/Keyword: IR Intensity

Search Result 286, Processing Time 0.033 seconds

A Study on an Infrared Illumination Stabilization Method in a Head Mounted Eye Tracking System for Sport Applications (착용형 시선 추적 장치의 스포츠 분야 적용을 위한 적외선 조명 변화 최소화에 관한 연구)

  • Lee, Sang-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.265-272
    • /
    • 2009
  • In this paper, a simple optical method that uses an infrared(IR) cut filter is proposed to minimize variation of eye image by external infrared(IR) sources in a video based head mounted eye tracking system that is used in the field of sports. For this, the IR cut filter is attached to a head mount of the eye tracking system, and the camera with an IR LED is located between the IR cut filter and eye. In this structure, external IR is blocked by the IR cut filter, and the IR intensity on the eye can be controlled by the IR LED. Therefore, the illumination condition of the camera to capture the eye can be stable without being affected by external IR illuminations. To verify the proposed idea, variation of the eye image and intensity of the IR with/without the IR cut filter is measured under various illumination conditions. The measured data show that the IR cut filter method can block external IR effectively, and complex pupil detection algorithms can be replaced by a simple binarized method.

Characteristics of Sustain Discharges in AC PDP with various Coplanar-Gaps and Auxiliary Electrode

  • Lee, Kyo-Sung;Shin, Nam-Hoon;Shin, Bhum-Jae;Choi, Kyung-Cheol;Jang, Sang-Hun;Park, Hyoung-Bin;Lee, Seong-Eui
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.175-178
    • /
    • 2005
  • The spatio-temporal behaviors of Infra Red(IR) emission images of the sustain discharges were observed in AC PDP with various coplanar-gaps and auxiliary electrode. When the height of barrier rib was fixed, IR intensity of the sustain discharges in AC PDP did not increase with increase of coplanar-gap. The IR efficiency of sustain discharges showed the similar behavior with the IR intensity. The IR intensity had its maixmum value when the coplanar-gap was $200\;{\mu}m$ and the height of barrier rib was $150\;{\mu}m$. It was also found that the auxiliary electrode in the front plate enhanced IR emission during sustain discharge when the pulse was applied to the auxiliary electrode.

  • PDF

Spectroscopic Evaluation on the Chemical Damage of Hair by Hydrogen Peroxide (과산화수소에 의한 모발의 화학적 손상에 관한 분광학적 평가)

  • Ha, Byung-Jo
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.579-581
    • /
    • 2011
  • Spectroscopic evaluation of hair chemical damage was performed by SEM/EDS, CLSM, and FT-IR spectroscopy. In SEM/EDS, hydrogen peroxide treated hair showed the loose packing of surface scales, lower ratio of sulfur element and higher ratio of oxygen atom. In the optical single section by using CLSM, high fluorescent intensity appeared in untreated hair. However, in case of treated hair, low fluorescent intensity appeared. This results the aromatic amino acids which can be autofluorescent were more abundant than bleached hair. FT-IR spectra showed that cysteic acid band intensity was increased by performing the bleaching treatments. These results indicate that the oxidative damage cleaves the S-S bond and results in the lower working force of hair fiber.

A Study on Effect of the Solar Elevation on the Ship IR Signature (태양고각 변화에 따른 함정 적외선신호에 관한 연구)

  • Kim, Yoon-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.38-45
    • /
    • 2010
  • A study on the infrared signature of a naval ship by the solar elevation was performed using the well known IR signature analysis software, ShipIR/NTCS. The contrast radiant intensity of a ship against the Eastern Sea background from sunrise to noon was investigated. Monthly averaged climate data for both January and July were applied to investigate the seasonal change in the signature. A study on the signature for different ship speeds was also carried out. Simulation results showed that the maximum signature in both wave-bands for a sea-level observer occurred at around 25~35 degrees of solar elevation and was highly dependent on the ship geometry rather than the solar irradiance.

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

A Study on Scattering Distribution in Metal of Ir-192 Gamma-Ray (Ir-192 $\gamma$선(線)의 금속(金屬)에 대(對)한 산란분포(散亂分布)에 관(關)한 연구(硏究))

  • Joo, Gwang-Tae
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.63-71
    • /
    • 1981
  • The metal-plates(Aluminium. Copper, Lead) of change the variation thickness have been penetrated by the collimated beam($450mm{\times}4mm{\phi}$) of Gamma-ray from $^{192}Ir$. Then, the scattered $\gamma$-ray dose in variable angle and the directly transmitted $\gamma$-ray dose were measured using the electrometer of ionization chamber. The results were summarized as follows: 1. Obtained the mass attenuation coefficients of $Al;0.0937cm^2g^{-1},\;Cu;0.0937cm^2g^{-1},\;pb;0.244cm^2g^{-1}$. 2. Total intensity of front scattered $\gamma$-ray follow the order of Al>Cu>pb. 3. The scattered $\gamma$-ray intensity with the lager angle of scattering was saturated after increase rapidly, and the scattering angle of the more larger was decreased. 4. The scattered $\gamma$-ray intensity through plates of aluminium or copper was saturated after increase with thicker scatterer, and the intensity was decreased at the more thicker. But the variation of scattered $\gamma$-ray dose in the lead plate made the fewest than Al and Cu. 5. The ratio of the scattered $\gamma$-ray dose and the directly transmitted $\gamma$-ray dose was saturated after increase with the thicker scatterer, and the scatterer of the more thicker was decreased. Degree of total intensity in these ratios was followed the order of Cu>Al>Pb.

  • PDF

Characteristics of Satellite Brightness Temperature and Rainfall Intensity over the Life Cycle of Convective Cells-Case Study (대류 세포의 발달 단계별 위성 휘도온도와 강우강도의 특성-사례연구)

  • Kim, Deok Rae;Kwon, Tae Yong
    • Atmosphere
    • /
    • v.21 no.3
    • /
    • pp.273-284
    • /
    • 2011
  • This study investigates the characteristics of satellite brightness temperature (TB) and rainfall intensity over the life cycle of convective cells. The convective cells in the three event cases are detected and tracked from the growth stage to the dissipation stage using the half-hourly infrared (IR) images. For each IR images the values of minimum, mean, and variance for the convective cell's TBs and the sizes of convective cells are calculated and also the relationship between TB and rainfall intensity are investigated, which is obtained using the pixel values of satellite TB and the ground rainfall intensity measured by AWS (Automatic Weather Station). At the growth stage of the convective cells, the TB's variance and cloud size consistently increased, whereas TB's minimum and mean consistently decreased. At this stage the empirical relationships between TB and rainfall intensity are statistically significant and their slopes (intercepts) in absolute values are relatively large (small) compared to those at the dissipation stage. At the dissipation stage of the convective cells, the variability of TB distributions shows the opposite trend. The statistical significance of the empirical relationships are relatively weak, but their slopes (intercepts) vary over life cycle. These results indicate that satellite IR images can provide valuable information in identifying the convective cell's maturity stage and in the growth stage, they may be used in providing considerably accurate rainfall estimates.

만기형 변광성들에 대한 SiO 메이저선 관측

  • Kim, Bong-Gyu;No, Deok-Gyu
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.155-166
    • /
    • 1992
  • We observed a total of 14 Mira variables as well as 4 late type variable stars for their SiO ${\nu}= 1$, J = 2 - 1 maser lines from April 1989 to November 1990 with the 13.7 m radio telescope at Daeduk Radio Astronomy Observatory. The maser intensity variations were the prime objective of the observations which well covered the periods of the variations. The origion of the variations were studied by comparing wi th those previousely measured in optical and infrared(IR) wavelengths and we confirmed that the intensity variations were in good correlation with those in V magnitude and IR intensity as previousely found in former investigators in general. However, for a few sources, we could find the missing maxima. The intensities themselves also were in good correlation with SiO ${\nu}\;=\;1$, J = 1 - 0 maser intensities observed in Yebes as expected. The good correlations indicate that the pumping source of the SiO maser is likely to be the IR emission in the masing regions and the "missing maxima" that are apparent in two particular sources are considered to relate wi th the strength of shocks arising from the eruptive mass-loss from central stars.

  • PDF

Infrared Signature Analysis of the Aircraft Exhaust Plume with Radiation Database (복사 데이터베이스를 활용한 항공기 배기 플룸 IR 신호 해석)

  • Cho, Pyung Ki;Gu, Bonchan;Baek, Seung Wook;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.568-575
    • /
    • 2016
  • For the combat survivability, an infrared signature emitted from aircraft is needed to be predicted and analyzed. In this study, we studied the infrared signature from the exhaust plume from the viewpoint of Infrared(IR) detector. The Line-By-Line method using the radiation database is used for radiative property, and radiative intensity analysis is conducted along 1-D line of sight based on the radiative property. The numerical thermo-fluid field for the plume is conducted by ANSYS FLUENT, while setting the lines of sight having the different detection angle on the thermo-fluid field. We found the high IR signature on the line of sight passing through the locally high temperature region of the plume inside, and the strongest signature from the line of sight toward the nozzle surface. Based on this, it confirms the influence of the surface radiative emission on the infrared signature.

Local Thresholding for Night Surveillance Image Using IR-LED (조명용 IR-LED를 이용한 야간감시영상에서의 국부이진화 방법)

  • Park, Moo-Kyung;Kim, Ki-Wan;Moon, Kyoung-Sup;Moon, Nam-Su
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.245-246
    • /
    • 2007
  • Recently, the problem of binarization in night surveillance image using IR-LED(InfraRed-LED) is an issue because the same object has different intensity in the image according to the distance between camera and the object. This paper introduces a new local thresholding technique based on the relative intensity of IR-LED that is acquired with the camera and installation informations.

  • PDF