• 제목/요약/키워드: IR Detector

Search Result 170, Processing Time 0.032 seconds

Vanadium Oxide Microbolometer Using ZnO Sandwich Layer

  • Han, Myung-Soo;Kim, Dae Hyeon;Ko, Hang Ju;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.178-183
    • /
    • 2015
  • Optical, electrical and structural properties of VOx/ZnO/VOx thin film are studied. The VOx/ZnO/VOx multilayer is deposited by using a radio frequency (RF) sputtering system. The VOx/ZnO/VOx thin film shows the high temperature coefficient of resistance (TCR) of $-3.12%/^{\circ}C$ and the low sheet resistance of about 80 $k{\Omega}/sq$ at room temperature. The responsivity and detectivity of the bolometer are measured as a function of modulation frequency.

Resource Allocation Scheme for Real-Time Traffic in MIMO-OFDMA Systems (MIMO-OFDMA 시스템에서 실시간 트래픽 적용을 위한 자원 할당 기법)

  • Lee, Jang-Uk;Yang, Suk-Chel;Shin, Yo-An
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.301-306
    • /
    • 2005
  • In this paper, we propose P-SRA (Proposed Simplified Resource Allocation) algorithm for efficient resource allocation for real time traffic in MIMO-OFDMA (Multiple Input Multiple Output - Orthogonal Frequency Division Multiple Access) systems with V-BLAST (Vertical-Bell laboratories LAyered Space-Time coding) detector. The proposed P-SRA scheme employs efficient 3 step resource allocation algorithm with plain V-BLAST and no H-ARQ, however it achieves comparable performance of a MIMO-OFDMA system utilizing error compensated V-BLAST and H-ARQ IR scheme.

  • PDF

The Research & Development of Infra-Red Flame Detector (적외선 불꽃감지기 개발연구)

  • 이복영;권오승;정창기;박상태;조성수
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • The radiant energy from a flaming fire of fuels containing carbonaceous material can be applied to fast growing fire. Raiant energy sensinsing technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not be applied. This study investigated the characteristics of sun light, artificial light and flame radiation light and the foundation technique of flame detecting is established. Pyroelectric element proper for the characteristics of flame radiant energy developed and circuit stabilizing technique, electro-magnetic immunity technique, durable and reliable operating technique to circuits developed.

  • PDF

PSD Sensor Module Based Monocular Motion Capture System (PSD센서모듈 기반 단안 모션캡쳐 시스템)

  • Kim, Yu-Geon;Ryu, Young-Kee;Oh, Choon-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.582-584
    • /
    • 2006
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system compact, low-cost, and only requires a one-time calibration at the factory. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The PSD sensor is placed in the focal plane of a wide-angle lens. The micro-controller calculates the 3D position of the markers using only the measured intensity and 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system's compact size, low-cost, ease of installation, and high frame rates are suitable for high speed motion tracking in games.

  • PDF

Optimum Installation Methods and Characteristics of the Hybrid Type Flame-Sensor (하이브라드형 화재감지기의 특성 및 최적 설치 방안)

  • Kim, Yeong-Min;Kim, Jong-Man;Shin, Dong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.286-286
    • /
    • 2010
  • In this paper, we proposed that optimum installation methods and characteristics of the hybrid type flame-sensor. The hybrid type flame-sensor has the high responsive performance. This research introduced the characteristics of the hybrid type flame-sensor, it was consist of IR/UV flame detector and proposed the optimum installation methods of false alarm reduced to resemble fire.

  • PDF

Development of a 3D Motion Capture System with Monocular PSD Camera and Two Active Markers (단안 PSD카메라와 두 능동마커를 이용한 3차원 모션인식 시스템 개발)

  • Seo, Pyeong-Won;Ryu, Young-Kee;O, Chun-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1026
    • /
    • 2008
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The micro-controller calculates the 3D position of the markers using only the measured intensity and the 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system has the advantages of the compact size, the low cost, the easy installation, and the high frame rates to be suitable for high speed motion tracking in games.

  • PDF

Improvement Residual Non-uniformity in Thermal Imaging System Using Correlated Double Sample Signal Processing (상관이중표본화 신호처리를 이용한 적외선 열상시스템의 잔여불균일성 개선)

  • Suk, Jung-Youp;Jang, Sung-Kun;Kim, Sung-Un;Yeou, Bo-Yeoun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1043-1044
    • /
    • 2008
  • In this study, a novel algorithm of the improvement residual non-uniformity (RNU) in thermal imaging system is proposed using correlated double sample signal processing. The proposed method attempts to eliminate offset variation of ROIC in IR detector causing the variation of FPA (focal plane array) temperature and suppling power. Experimental results show that the proposed method confirmed a better performance than the existing RNU system.

  • PDF

Determination of Amine Compounds Using 1-(N,N-Dimethylamino) pyrene-6-sulfonyl chloride as a New Fluorescent Derivatizing Reagent for HPLC (새로운 HPLC용 형광유도체화제인 1-(N,N-dimethylamino) pyrene-6-sulfonyl chloride를 이용한 아민화합물의 분석)

  • 이윤중;김용희;조정길
    • YAKHAK HOEJI
    • /
    • v.35 no.4
    • /
    • pp.288-294
    • /
    • 1991
  • A new fluorescent derivatizing reagent was developed to be used in HPLC for the trace determination of primary and secondary amines. This new reagent, 1-(N,N-dimethylamino)pyrene-6-sulfonyl chloride, was synthesized by the chlorination of sodium 1-(N,N-dimethylamino)pyrene-6-sulfonate which was obtained from 1-(N,N-dimethylamino)pyrene after sulfonation. Ephedrine and norephedrine were derivatized quantitatively by this reagent. The optimum conditions for the derivatization such as pH, reagent concentration, reaction time and reaction temperature ware examined. The structures of derivatives were identified by IR, $^{1}$H-NMR and MS methods. The fluorescence properties and the stability of the derivatives were examined. The derivatives were separated on silica column with an isocratic elution using the mixture of n-hexane and ethylacetate and monitored by fluorescene detector. Linear calibration curves were obtained and detection limits in a 10 $\mu$l injection volume were 5 picomole for ephedrine and norephedrine.

  • PDF

The Fabrication of Microlens Array (초소형 렌즈 배열의 제작에 관한 연구)

  • Moon, Sung-Wook;Kim, Hee-Youn
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.279-285
    • /
    • 2001
  • In this study, we fabricated the microlens array using very simple and economical method which used Si molds made by bulk etching in HNA and spreaded SU-8 on top of the Si mold. And, we developed fabrication conditions for high fill factor microlens array that is $45{\mu}m$ in height and $150{\mu}m$ in diameter. This microlens array can be used for imaging system like IR detector or projection display. It is expected that it can improve the characteristics of these devices.

  • PDF

Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications (몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.