• Title/Summary/Keyword: IR Camera

Search Result 293, Processing Time 0.023 seconds

Development of Interferometer for Performance Assessment of IR Optical System (적외선 광학계통 성능평가를 위한 간섭계 개발)

  • 홍경희;고재준;이성태;장세안;오명호
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.179-185
    • /
    • 1991
  • Twyman-Green interferometer is developed for assessment of IR optical system performance. Light source is $CO_2$ gas laser which has 10.6$\mu \textrm m$ wavelength. The light beam is expanded to 2.5 cm dia by Ge lens and splitted by ZnSe parallel plane plate. One of the beams is reflected by refernce mirror which is operated PZT. The fringe will be detected by a pyro-electric vidicon camera and displayed by a CRT monitor. Here, the IR firinge is recorded on the thermal paper. In visible region, the light source is He-Ne laser. The fringe is detected by a CCD camera and displayed by the CRT monitor. The intensity of the fringe is digitized by a image card and processed by a PC. The wavefront aberration function, PSF and OTF are calculated. The results are displayed in 3-D graphs on the monitor or printed out by a line printer.

  • PDF

Tensile Characterization of Ceramic Matrix Composites (CMCs) with Nondestructive Evaluation (NDE) Techniques

  • Kim, Jeongguk;Lee, Joon-Hyun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.190-194
    • /
    • 2003
  • Two different types of nondestructive evaluation (NDE) techniques were employed to investigate the tensile behavior of ceramic matrix composites (CMCs). Two NDE methods, ultrasonic testing (UT) and infrared (IR) thermography, were used to assess defects and/or damage evolution before and during mechanical testing. Prior to tensile testing, a UTC-scan and a xenon flash method were performed to obtain initial defect information in light of UT C-scans and thermal diffusivity maps, respectively. An IR camera was used for in-situ monitoring of progressive damages. The IR camera measured temperature changes during tensile testing. This paper has presented the feasibility of using NDE techniques to interpret structural performance of CMCs.

  • PDF

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

Analysis of Thermal Distribution inside LCD Monitor by Development of Prediction Formula for Inner Temperature (내부 온도 추정식 개발에 의한 LCD 모니터 내부의 열분포 분석)

  • Oh, S.J.;Ko, H.S.;Chung, D.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.487-488
    • /
    • 2006
  • In these days, demand of a LCD monitor is remarkably increasing with development of the LCD technology. However, there are thermal problems for improvement of efficiency for the LCD monitor. Thus, this research analyzed thermal problems such as convection and conduction heat transfer characteristics in the LCD monitor using an infrared (IR) camera. Also, the results of the outer side of the front LCD panel using the IR camera have been compared with the results of the inner side of the front panel using T-type thermocouples. The equations have been derived for the temperature distribution of the inner side of the front LCD panel by a multiple regression method including variables for ambient temperature, humidity and temperature differences between the front and back panels of the LCD monitor.

  • PDF

Appropriate Digital Camera System for Digital Ultraviolet Photography (디지털 자외선 사진을 위한 적정 디지털 카메라 시스템)

  • Lee, Young-Kyu;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.40-48
    • /
    • 2010
  • Reflected-Ultraviolet photography is applied to the evidence of crime, Archaeology, and Dermatology. In the past, Ultraviolet photography was done with standard black-and-white film. Because emulsion of film is more sensitive to near UV light than CCD(Charge Coupled Device) or CMOS(Complementary Metal-Oxide-Semiconductor)of digital camera. In this research, we purpose to improve qulity of ultraviolet photographs and to find out the best alternative digital camera by utilizing a cunsumer digital camera. To achieve theses, we removed IR cutoff filter from digital camera. And by using modified UV pass filter, we verified the increase of image resolution of digital ultraviolet photographs. Also, we analyze reproducibility of digital ultraviolet photographs according to type, size, pixel of image sensor. Furthermore, this research resulted in the development of an practical digital camera system by utilizing a cunsumer digital camera. Eventually, it will contribute to practical use in the various field of digital ultraviolet photographs

Optical and Near-IR Photometry of the NGC 4874 Globular Cluster System with the Hubble Space Telescope

  • Cho, Hyejeon;Blakeslee, John P.;Peng, Eric W.;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.37.1-37.1
    • /
    • 2013
  • We present our study of analyzing the photometric properties of the globular cluster (GC) system which resides in the extended halo of the central bright Coma cluster galaxy NGC 4874. The core of the Coma cluster of galaxies (Abell 1656) was observed with both the HST Advanced Camera for Surveys (ACS) in the F475W (g475) and F814W (I814) and Wide Field Camera 3 IR Channel (WFC3/IR) in the F160W (H160) filters. The data analysis procedure and GC candidate selection criteria are briefly described. We investigate the interesting "tilt" features in color-magnitude diagrams for this GC system and their link to the nonlinear color-metallicity relation for GCs. The NGC 4874's GC system exhibits a bimodal distribution in the optical g475-I814 color and much more than half the GCs fall in the red side at g475-I814 ~ 1.1. This bimodality is weakened in the optical-IR I814-H160 color; the quantitative analysis on the features of both color distributions using the Gaussian Mixture Modeling code proves the bimodalities are different. Both colors, thus, cannot linearly reflect the bimodality of an underlying metallicity, supporting the suggestion that observed bimodalities in extragalactic GC colors are the metallicity-to-color projection effect.

  • PDF

Design of IR Camera based Wearable Keyboard for Smart UX (스마트 UX용 IR 카메라 기반의 웨어러블 키보드 설계)

  • Park, H.Y.;Lee, E.S.;Nam, G.S.;Kang, M.G.;Jung, S.M.;Yeo, H.G.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.501-502
    • /
    • 2015
  • In this paper, a infra red-camera based wearable keyboard for variable UX(User eXprience) in smart platform was proposed with finger-tracking for anywhere portable devices. This virtual wearable keyboard was designed with OpenCV and MFC for the applying of 'fingertip tracking' and 'k-cuvature' algorithm with 2 IR-cameras.

  • PDF

Real-Time Eye Tracking Using IR Stereo Camera for Indoor and Outdoor Environments

  • Lim, Sungsoo;Lee, Daeho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.8
    • /
    • pp.3965-3983
    • /
    • 2017
  • We propose a novel eye tracking method that can estimate 3D world coordinates using an infrared (IR) stereo camera for indoor and outdoor environments. This method first detects dark evidences such as eyes, eyebrows and mouths by fast multi-level thresholding. Among these evidences, eye pair evidences are detected by evidential reasoning and geometrical rules. For robust accuracy, two classifiers based on multiple layer perceptron (MLP) using gradient local binary patterns (GLBPs) verify whether the detected evidences are real eye pairs or not. Finally, the 3D world coordinates of detected eyes are calculated by region-based stereo matching. Compared with other eye detection methods, the proposed method can detect the eyes of people wearing sunglasses due to the use of the IR spectrum. Especially, when people are in dark environments such as driving at nighttime, driving in an indoor carpark, or passing through a tunnel, human eyes can be robustly detected because we use active IR illuminators. In the experimental results, it is shown that the proposed method can detect eye pairs with high performance in real-time under variable illumination conditions. Therefore, the proposed method can contribute to human-computer interactions (HCIs) and intelligent transportation systems (ITSs) applications such as gaze tracking, windshield head-up display and drowsiness detection.

Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications (몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.