• Title/Summary/Keyword: IQ

Search Result 385, Processing Time 0.028 seconds

Prospect of Treatment with Herb Medicine for Developmental Delay of Language and Intelligence Quotient (어지와 지능지수에 대한 한약치료의 전망)

  • Park, Jae-Hyung;Park, Jae-Hyun;Yun, Young-Ju;Jeong, Seul-Ki;Lim, Ja-Sung;Paeck, Eun-Kyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.1025-1029
    • /
    • 2007
  • It is widely assumed that Intelligence Quotient (IQ) is determined by inherent disposition and environmental factor. IQ is estimated by age-conversion score and stabilized around age 4 and IQ of adult age can be predicted after age 10. Though children with Mental Retardation (MR) are delayed in language development since early infant period, they receive only special education including speech and language therapy, but no special medication. In traditional Korean medicine, the etiology and treatment for developmental delay of language have been handed down for a long time. Some studies on herbs and prescriptions for improving language development have been undertaken recently. We have found several cases of significant elevation of IQ in the children treated with long term medications of Korean herbal medicine for improvement of language. Analyzing these cases, especially performance IQ showed significant change. Therefore we suggest that Korean herbal medicine might improve cognition development in children with MR.

A Study on Transmission Signal Design Using DAC to Reduce IQ Imbalance of Satellite-Mounted Synthetic Aperture Radar Transmitter (위성 탑재 영상레이다 송신기의 IQ 불균형 저감을 위한 DAC를 이용한 송신 신호 설계 기법에 관한 연구)

  • Lee, Young-Bok;Kang, Tae-Woong;Lee, Hyon-Ik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.144-150
    • /
    • 2022
  • The on-board processor of satellite synthetic aperture radar(SAR) generates transmission signal by digital signal processing, converts it into an analog signal. At this time, the transmission signal generated from the baseband requires the frequency modulation to convert it to the high-frequency band in order to improve the stability. General frequency modulation method using local oscillator(LO) causes IQ imbalance due to phase error/magnitude error and these error reduce performance of SAR. To generate transmission signal without phase/magnitude error, this paper suggests design method of the frequency modulation method using digital to analog converter(DAC) at on-board SAR. For design, this paper analyzes the characteristic of DAC mode and uses pre-compensation filter. To analyze the proposed method performance, performance index are compared with IQ imbalance signals. This method is suitable for on-board SAR using fast sampling DAC and has the advantage of being able to solve IQ imbalances.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

Auditory and Visual P300 in ADHD Children with Higher and Lower IQ : Pilot Study

  • Wang, Sheng-Min;Jeon, Yang-Whan;Han, Sang-Ick;Park, E-Jin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.22 no.4
    • /
    • pp.211-218
    • /
    • 2011
  • Objectives : Intellectual impairment in children with attention-deficit hyperactivity disorder (ADHD) is often associated with relatively severe cognitive dysfunction. This study was designed to investigate cognitive function using auditory and visual event-related potential P300 in children with ADHD with relatively higher and lower IQ. Methods : A total of 20 children aged 6-12 years with DSM-IV-TR diagnosis of ADHD-combined type were recruited. For 10 children with lower IQ (${\leq}$100) and 10 children with higher IQ (>100), auditory and visual P300 using oddball paradigm (target 0.2, standard 0.8, in probability) were employed. Results : No significant differences were found in P300 amplitude and latency between ADHD children with higher and lower IQ in both modalities. However, auditory P300 amplitude in the right parietal area (P8 electrode) was negatively correlated with verbal IQ in ADHD subjects (R=-.50, p<.05). Visual P300 amplitude in the left parietal area (P3 electrode) was positively correlated with performance IQ in ADHD subjects (R=.57, p<.01). Conclusion : This study suggests intellectual impairment, as evidenced by lower IQ, could not be associated with cognitive dysfunction reflected in event-related potential P300 in ADHD children. However, cognitive function reflected in intellectual subcomponents and P300 might be processed in a stimulus modality-specific and asymmetric pattern.

In-vitro antioxidant activity of flavonoids from Acer okamotoanum

  • Kim, Ji Hyun;Kim, Hyun Young;Lee, Sanghyun;Cho, Eun Ju
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.4
    • /
    • pp.761-767
    • /
    • 2018
  • Degenerative diseases are commonly associated with excess free radicals. Acer okamotoanum, a plant endemic to Korea, is reported to have anti-oxidant, anti-cancer, and anti-viral activities. We previously isolated flavonoids from the ethyl acetate fraction of A. okamotoanum such as quercitrin (QU), isoquercitrin (IQ), and afzelin (AF). In the present study, the in vitro antioxidant activity of flavonoids such as QU, IQ, and AF isolated from the ethyl acetate fraction of A. okamotoanum were investigated by measuring the free radical scavenging activity including 1,1-diphenyl-2-picrylhydrazyl (DPPH), hydroxyl radical ($^{\cdot}OH$), and superoxide anion ($O_2{^-}$). The flavonoids (QU, IQ, and AF) concentration-dependently showed a DPPH radical scavenging activity. In particular, QU and IQ showed a higher DPPH radical scavenging activity than that of AF. In addition, the flavonoids (QU, IQ, and AF) at $10{\mu}g/mL$ showed over an 80% scavenging effect against $^{\cdot}OH$ radical production. Furthermore, the $O_2{^-}$ radical scavenging activity of the flavonoids, QU, IQ, and AF increased in a dose-dependent manner. Particularly, IQ exerted the strongest scavenging activities against $^{\cdot}OH$ and $O_2{^-}$ radicals among the other flavonoids. These results indicate that the flavonoids from A. okamotoanum, in particular IQ, would have a protective activity against oxidative stress induced by free radicals, and potentially be considered as a natural antioxidant agent.

A Comparison of Deep Learning Models for IQ Fingerprint Map Based Indoor Positioning in Ship Environments

  • Yootae Shin;Qianfeng Lin;Jooyoung Son
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.4
    • /
    • pp.1122-1140
    • /
    • 2024
  • The importance of indoor positioning has grown in numerous application areas such as emergency response, logistics, and industrial automation. In ships, indoor positioning is also needed to provide services to passengers on board. Due to the complex structure and dynamic nature of ship environments, conventional positioning techniques have limitations in providing accurate positions. Compared to other indoor positioning technologies, Bluetooth 5.1-based indoor positioning technology is highly suitable for ship environments. Bluetooth 5.1 attains centimeter-level positioning accuracy by collecting In-phase and Quadrature (IQ) samples from wireless signals. However, distorted IQ samples can lead to significant errors in the final estimated position. Therefore, we propose an indoor positioning method for ships that utilizes a Deep Neural Network (DNN) combined with IQ fingerprint maps to overcome the challenges associated with accurate location detection within the ship. The results indicate that the accuracy of our proposed method can reach up to 97.76%.

A Study on the Usefulness of Korean version of Checklist for Behavioral (영재아 판별에서 한국판 영재아 행동특성 체크리스트의 유용성에 관한 연구)

  • 윤여홍
    • Journal of Gifted/Talented Education
    • /
    • v.8 no.2
    • /
    • pp.1-30
    • /
    • 1998
  • Characteristics of Superior Children as a Screening Test of Gifted students The purpose of this study was to investigate the usefulness of Korean version of checklist for behavioral characteristics of superior children as a screening test for gifted students. Total 397 children were tested KEDI-WISC (Korean version of Wechsler Intelligence Scale for Children), and their parents or primary caretakers took the checklists for behavioral characteristics of superior children individually. Total subjects were divided into 3 groups based on their Full IQ score of KEDI-WICS. The children of IQ 130 and over was gifted group, and those of IQ 115-130 was superior group, and those of below IQ 115 was average group. The analyses of behavioral checklist scores among the groups, gender, grades differences and item analysis of behavioral checklist were done for the purpose of discrimination among 3 groups. As a result, it was found that the Korean version of checklist for behavioral characteristics of superior children was very useful as a screening test for gifted correlations between checklist scores and verbal, performance and full IQ scores were significantly high, which means that IQ and checklist scores were very related. Twenty out of 50 items were found to be discrimination items between gifted and superior group. However, there was no significant difference between grades and gender on the checklist score.

  • PDF

Derivation and Analysis of the BER Closed Form in the OFDM Communication System with IQ Imbalance

  • Hieu Nguyen Thanh;Kang Byung-Su;Lee Kwang-Chun;Ryu Heung-Gyoon
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.3
    • /
    • pp.182-188
    • /
    • 2006
  • Orthogonal frequency division multiplexing(OFDM) is very useful for the wireless communication system. However, OFDM is very sensitive to the radio frequency impairments. One of the most important major impairments is the IQ imbalance between in-phase(l) and quadrature(Q) branches in the up and down-conversion. IQ imbalance can be divided into phase and amplitude imbalances. These imbalances make constellation of signal to expand and rotate. The performance of system is severely degraded. In this paper, a closed-form for the bit error probability of the OFDM signal in IQ imbalance environment is derived in terms of the function of phase and amplitude imbalance parameters. So, it will be convenient and useful to evaluate the performance of OFDM communication system with IQ imbalance. It is confirmed that computer simulation results closely match with the results of the analytical derivation. When phase imbalance $\varphi=20^{\circ}$, amplitude imbalance $\varepsilon=0.1$; 0.3; 0.4; 0.5, BER at $10^{-5}$ is severely degraded by 1.8 dB, 3.12 dB, 4.72, and 8.44 dB, respectively.

Baseband Signal Compensation Scheme for Frequency Selective Fading Channel and RF Impairments in OFDM System (OFDM 시스템에서 주파수 선택적 페이딩 채널과 RF 불완전 변환 극복을 위한 기저대역 신호보상 기법)

  • Kim, Jae-Kil;Kim, Jeong-Been;Hwang, Jin-Yong;Shin, Dong-Chul;Ahn, Jae-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.55-64
    • /
    • 2010
  • In this paper, we propose a new compensation scheme for combined channel distortions and RF impairments based on the analysis of the impacts of IQ(In-phase/Quadrature) imbalance and phase noise on the OFDM(Orthogonal Frequency Division Multiplexing) system in the direct conversion transceiver and frequency selective fading channel distortion. The proposed scheme estimates the combined distortion by the use of training symbols and the residual distortion by pilot symbols and compensates the combined distortion, including IQ imbalance, phase noise and multipath fading at the same time. The simulation results show that the proposed scheme compensates the combined distortion of IQ imbalance, phase noise and multipath fading simultaneously.