• Title/Summary/Keyword: IPS system

Search Result 270, Processing Time 0.021 seconds

Esthetic Rehabilitation of Anterior Dentition by All Ceramic Crowns Using IPS e.max CAD : A Case of Tetracycline Discoloration (전치부 전부도재관을 이용한 테트라싸이클린 착색의 심미보철 회복 증례 (IPS e.max CAD 블록의 이용))

  • Kim, Jae-Hong;Cho, Young-kyu;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • The purpose of this case report was to present an example of an esthetic and functional rehabilitation of anterior teeth with tetracycline discoloration and minor morphological abnormality of a 39-year old female. A chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with CEREC AC was applied for the prosthetic procedure and all ceramic crowns made with lithum disilicate (IPS e.max CAD) restored the esthetic and functional features of sixteen anterior teeth successfully.

Study on Cost Reduction Device Industry ICM application development (장치산업에서 원가절감방법론(ICM)개발 적용에 관한 연구)

  • Kim, Jong-Ouk;Bahng, Chan-Seok;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.109-118
    • /
    • 2016
  • IPS(Ideal Production System) is a strategic cost management establishing ideal target cost, innovating cost structure and reduction. However, IPS was commonly used in assembly industry acquiring components and using them to assemble vehicles etc. Applying IPS to steel industry is a new try and not easy because cost elements in flow manufacturing are clustered and obfuscated in a complicated way. This paper proposes ICM (Ideal Cost Management) method adaptive to steel industry. One of the biggest advantages is that ICM could classify and categorize costs in detail according to accounts and manufacturing machines. Based on ICM information, steps of extracting and maximizing ideas are followed effectively. From 2013, ICM was applied successfully to POSCO Pohang Steel Works 38 factories.

A STUDY ON THE MARGINAL FIDELITIES AND FRACTURE STRENGTH OF IPS EMPRESS $2^(R)$ CERAMIC CROWNS (IPS Empress $2^(R)$를 이용한 전부도재관의 변연적합성과 파절강도에 관한 연구)

  • Yu, Ji-Hyoung;Kim, Yong-Cheol;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.606-617
    • /
    • 2000
  • The purpose of this study was to measure the marginal fidelities and the fracture strength of IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$ ceramic crowns. After constructed of 12 experimental dies for each group, ceramic crowns were fabricated on the metal master dies prepared on the maxillary right premolar Marginal gaps were measured on the specimen between the margin of each crown and finish-ing line of the metal master die by using stereo-microscope($SZ-ST^{(R)}$ Olympus, Japan) and all specimens were cemented on the metal master die with Bistite $II^{(R)}$ (Tokuyama soda Co, LTD., Japan) resin cement. Finally marginal gaps were measured again. To measure of the fracture strength, buccal incline on the functional cusp of specimens were loaded until the catastrophic failure occurred by using the AGS-1000 $D^{(R)}$(Shimadzu, Japan). The result of marginal fidelities and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows : 1. No significant difference was found in the mean marginal fidelities and fracture strength between the IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$. 2. In comparison of marginal fidelities between before and after cementation, there was significant difference(P<0.05). The IPS Empress 2 system was shown in this study that had good marginal fidelities and fracture strength compared to In-Ceram ceramics. Although this system was acceptable to clinical applications, the system still has to be considered long-term researches about marginal fidelities and fracture strength due to the lack of data about the clinical researches.

  • PDF

Design of Intrusion Prevention System(IPS) in Linux Environment (Linux 환경에서의 침입방지시스템(IPS) 설계)

  • 이상훈;김우년;이도훈;박응기
    • Proceedings of the Korea Information Assurance Society Conference
    • /
    • 2004.05a
    • /
    • pp.21-26
    • /
    • 2004
  • The growth of incidents on the Internet has reflected growth of the internet itself and growth of the computing power. while in previous years, external attacks tended to originate from those interested trend in exploring the Internet for its own sake and testing their skills, there is an increasing trend towards intrusions motivated by financial, political, and military objectives. so, attacks on the nation's computer infrastructures are becoming an increasingly serious problem. Even though the problem is ubiquitious, government agencies are particularly appealing targets and they tend to be more willing to reveal such events than commercial organizations. The threat of damage made necessity of security's recognition, as a result, many researches have been carried out into security of system actively. Intrusion Detection technology is detection of intrusion using audit data differently from using traditional simple filtering and informs manager of it. It has security manager of system deal with the intrusion more quickly. but, cause current environment of Internet manager can't doing response Intrusion alert immediately. That's why IPS needed. IPS can response automatically the intrusion alert. so, manager is more comfortable and can response quickly.

  • PDF

Dynamically Reconfigurable SoC 3-Layer Bus Structure (동적 재구성이 가능한 SoC 3중 버스 구조)

  • Kim, Kyu-Chull;Seo, Byung-Hyun
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • Growth in the VLSI process and design technology is resulting into a continuous increase in the number of IPs on a chip to form a system. Because of many IPs on a single chip, efficient communication between IPs is essential. We propose a dynamically reconfigurable 3-layer bus structure which can adapt to the pattern of data transmission to achieve an efficient data communication between various IPs. The proposed 3-layer bus can be reconfigured to multi-single bus mode, and single-multi bus mode, thus providing the benefits of both single-bus and multi-bus modes. Experimental results show that the flexibility of the proposed bus structure can reduce data transmission time compared to the conventional fixed bus structure. We incorporated the proposed bus structure in a JPEG system and verified that the proposed structure achieved an average of 22% improvement in time over the conventional fixed bus structure.

  • PDF

The Comparative Study on Performance Analysis of Windows 7 and Ubuntu Applying Open Source IDS/IPS Suricata (오픈소스 IDS/IPS Suricata를 적용한 Windows7과 Ubuntu 성능 비교 분석)

  • Seok, Jinug;Kim, Jimyung;Choi, Moonseok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.141-151
    • /
    • 2017
  • Nowadays, It is undeniable that the threat of network security is growing as time flows due to worldwide development of wire/wireless, various Internet platform and sophisticated hacking techniques. The amount of traffics that Network security solution has to handle is increasing and recently many occurrence of explosive traffic attacks from PulseWave are being observed which has many similar characteristics to New DDos. Medium and small sized firms abroad have developed and distributed Snort and Suricata that are based on open-source Intrusion Detection System(IDS) / Intrusion Prevention System (IPS). The goal of this study is to compare between Windows7 by applying suicata 4.0.0 32bit version and Ubuntu 16.04.3 LTS by applying suicata 4.0.0 version which is an open source Intrusion Detection System / Intrusion Protection System that uses multi threads method. This experiment's environment was set as followed C1100 server model of Dell, Intel Xeon CPU L5520 2.27GHz*2 with 8 cores and 16 threads, 72GB of RAM, Samsung SSD 250GB*4 of HDD which was set on RAID0. According to the result, Suricata in Ubuntu is superior to Suricata in Windows7 in performance and this result indicates that Ubuntu's performance is far advanced than Windows7. This meaningful result is derived because Ubuntu that applied Suricata used multi core CPU and RAM more effectively.

A Proposal of Remaining Useful Life Prediction Model for Turbofan Engine based on k-Nearest Neighbor (k-NN을 활용한 터보팬 엔진의 잔여 유효 수명 예측 모델 제안)

  • Kim, Jung-Tae;Seo, Yang-Woo;Lee, Seung-Sang;Kim, So-Jung;Kim, Yong-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.611-620
    • /
    • 2021
  • The maintenance industry is mainly progressing based on condition-based maintenance after corrective maintenance and preventive maintenance. In condition-based maintenance, maintenance is performed at the optimum time based on the condition of equipment. In order to find the optimal maintenance point, it is important to accurately understand the condition of the equipment, especially the remaining useful life. Thus, using simulation data (C-MAPSS), a prediction model is proposed to predict the remaining useful life of a turbofan engine. For the modeling process, a C-MAPSS dataset was preprocessed, transformed, and predicted. Data pre-processing was performed through piecewise RUL, moving average filters, and standardization. The remaining useful life was predicted using principal component analysis and the k-NN method. In order to derive the optimal performance, the number of principal components and the number of neighbor data for the k-NN method were determined through 5-fold cross validation. The validity of the prediction results was analyzed through a scoring function while considering the usefulness of prior prediction and the incompatibility of post prediction. In addition, the usefulness of the RUL prediction model was proven through comparison with the prediction performance of other neural network-based algorithms.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

A study on the arrangement of integrated power system for warship (함정의 통합 전력시스템 구성에 관한 연구)

  • Baek, Hyun-Min;Jung, Kyun-Sik;Lee, Myung-Ho;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1070-1074
    • /
    • 2014
  • According to IEEE 1662(2009), IPS is a power system where all prime movers produce electrical power that is shared among propulsion, mission, and ship service loads. Discriminating attributes of integrated power systems are flexibility of movers' arrangements, mechanical decoupling between prime movers and propulsors, an increased level of energy conversion and transmission redundancy, and flexibility of redistributing available electrical power for future electronic weapons. IPS could have various steps of power that can be produced at optimal load of movers. In this study, an evaluation method for optimal arrangement of movers was investigated when an IPS warship is projected. The two factors are utilized for the quantitative analysis which are the weight of system as the fighting power and the fuel consumption per year as the economic feasibility. And also the ways for arrangement of system were studied according to existence of small diesel generator. The evaluation method that decides the optimization level is based on the DEA(Data Envelopment Analysis)

Integrated Control Center on the drawing board for the Northeast Asia Region Interconnected Power System (동북아 연합급전소 구상)

  • Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.20-23
    • /
    • 2005
  • This paper introduces the latest discussions on the Integrated Dispatch Center (IDC, or Integrated Control Center: ICC) for the Northeast Asia Region Interconnected Power System (NEAR-IPS). The IDC is for the safety and economical operation of the NEAR-IPS. The status and plans of the EPSs and the control systems (or dispatch centers) to be interconnected shall be reviewed and the consideration on the IDC to be built in the future shall be discussed.

  • PDF