• Title/Summary/Keyword: IPS Empress Crown

Search Result 31, Processing Time 0.028 seconds

MARGINAL FIT OF CELAY/IN-CERAM, CONVENTIONAL IN-CERAM AND EMPRESS 2 ALL-CERAMIC SINGLE CROWNS (Celay/In-Ceram, Conventional In-Ceram, Empress 2 전부도재관의 변연적합도에 관한 비교 연구)

  • Yang, Jae-Ho;Yeo, In-Sung;Lee, Sun-Hyung;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.131-139
    • /
    • 2002
  • There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But many of statistical inferences are not definite because of sample size, measurement number, measuring instruments. etc. The purpose of this study was to compare the marginal adaptations of the anterior single restorations made by different systems and to consider more desirable statistical methods in analysing the marginal fit. The in vitro marginal discrepancies of three different all-ceramic crown systems (Celay In-Ceram. Conventional In-Ceram. IPS Empress 2 layering technique) and one control group (PFM) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. 10 crowns per each system were fabricated. Measurements or a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Non-parametric statistical analysis was performed for the results. Within the limits of this study, the following conclusions were drawn: 1 Mean gap dimensions and standard deviations at the marginal opening for the maxillary incisor crowns were $98.2{\pm}40.6{\mu}m$ for PFM, $83.5{\pm}18.7{\mu}m$ for Celay In-Ceram, $104.9{\pm}44.1{\mu}m$ for conventional In-Ceram, and $45.5{\pm}11.5{\mu}m$ for IPS Empress 2 layering technique. The IPS Empress 2 system showed the smallest marginal gap (P<0.05). The marginal openings of the other three groups were not significantly different (P<0.05). 2 The marginal discrepancies found in this study were all within clinically acceptable standards ($100\sim150{\mu}m$). 3. When the variable is so controlled that the system may be the only one, mean value is interpreted to be the marginal discrepancy of a restoration which is made by each system and standard deviation is to be technique-sensitivity of each one. 4. From the standard deviations. the copy-milling technique (Celay/In-Ceram) was not considered to be technique-sensitive in comparison with other methods. 5. Parametric analysis is more reliable than non-parametric one in interpretation of the mean and standard deviation. The sample size of each group has to be more than 30 to use parametric statistics. The level of clinically acceptable marginal fit has not been established. Further studies are needed.

A STUDY ON THE MICROLEAKAGE OF THE IPS EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPES AND RESIN CEMENT (변연형태와 레진시멘트에 따른 IPS Empress 도재관의 변연누출에 관한 연구)

  • Jung, Won-Yeob;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.789-805
    • /
    • 1998
  • The purpose of this study was to compare the microleakage of the IPS Empress ceramic crown according to 1) margin types such as rounded shoulder and bevel, 2) margin locations such as enamel and dentine, 3) resin cement types such as Variolink and Bistite. For this study, 80 extracted premolar teeth were used. After 10 experimental dies were prepared for each group, the IPS Empress ceramic crowns were fabricated on the dies and cemented with one of two types of resin cement. After 1,000 cycles of thermal changes were given with the thermocycling unit, each specimen was sectioned with a low speed diamond saw in both the buccolingual and the mesiodistal direction. The microleakage was then measured with a stereo microscope. The obtained results were as follows : 1. Every experimental group showed microleakage. The microleakage of the crowns which had a rounded shoulder on enamel cemented with Variolink was the lowest of all. The resulting rank of the mean microleakage was rounded shoulder on enamel using Variolink(0.601mm), rounded shoulder on enamel using Bistite (0.794mm), bevel on enamel using Variolink (0.826mm), rounded shoulder on dentine using Variolink(1.054mm), bevel on enamel using Bistite(1.087mm), rounded shoulder on dentine using Bistite(1.176mm), bevel on dentine using Variolink(1.258mm), and bevel on dentine using Bistite(1.467mm). 2. The statistically significant differences in the microleakage were found in 4 cases: rounded shoulder on enamel using Variolink and bevel on dentine using Variolink, rounded shoulder on enamel using Variolink and bevel on dentine using Bistite, rounded shoulder on enamel using Bistite and bevel on dentine using Bistite, bevel on enamel using Variolink and bevel on dentine using Bistite. 3. The microleakage of rounded shoulder finish line was lower than that of bevel finish line. The statistically significant differences were found with respect to the type of finish lines. 4. The microleakage of the finish line on enamel was lower than that of finish line on dentine. The statistically significant differences were found with respect to the location of the finish lines. 5. The microleakage of the Variolink cement was lower than that of the Bistite cement. The statistically significant differences were found with respect to the resin cements.

  • PDF

A STUDY THE SHADE CHANCE OF SEVERAL KINDS OF ALL CERAMIC CROWNS USED FOR METAL DOWEL CORE (금속 다우엘코어에 사용된 수종의 전부도재관의 색조변화에 관한 연구)

  • Hur Sung-Il;Lim Heon-Song;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.477-491
    • /
    • 2001
  • The purpose of this study is to compare and analyze the shade changes(${\Delta}E^*$) about $In-Ceram^{(R)}$, $IPS-Empress^{(R)}$, $OPC^{(R)}$ by using of the spectrophotometer arising from inital status and before and after cementation of the resin cement mounted on the metal core. We used a couple of statistics such as 'One- Way ANOVA' and 'Multiple Range Test.' We could be able to verify significantly what is being discussed here up to 95%. The results drawn from our research are as follows : 1. At the time of our experiments regarding the initial shapes of all-ceramic and mounting status of all-ceramic on the metal crown(${\Delta}E^*1$), and a comparison of mounting of all ceramic on the metal crown with all-ceramic cemented on the metal core(${\Delta}E^*2$), at the time of shade change of initial shapes and after we cemented on the metal core. (1) no significant difference among all-ceramics was found. (2) no particular difference was found regarding the $In-Ceram^{(R)}$. (3) a significant difference between the ${\Delta}E^*1$ and ${\Delta}E^*2$ regarding the $IPS-Empress^{(R)}$ was found(P<0.05). (4) a significant difference between the ${\Delta}E^*1$ and ${\Delta}E^*2$ regarding the $OPC^{(R)}$ was found(P<0.05). 2. When we compared the shade changes(${\Delta}E^*$) resulted from before and after the cementation on each of the parts involved of some all-ceramic, we could be able to find shade change increase form incisal third, middle third. and cervical third in that order in $In-Ceram^{(R)}$(spinell), IPS $Empress^{(R)}$, and $OPC^{(R)}$ all. In addition. we could be able to find a significant difference between cervical third and incisal third, middle third. (P<0.05) From what we have just seen, we might conclude that there is a significant shade change difference before and after the cementation with respect to $IPS-Empress^{(R)}$ and $OPC^{(R)}$. In addition, we could also be able to find more shade change difference at the cervical third rather than incisal third and middle third depending on the parts involved.

  • PDF

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary First Premolar (상악 제1소구치에서 전부도재관의 finish line 형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Lee, Sang-Kwon;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.219-237
    • /
    • 2003
  • he purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown, and 0.5mm width chamfer finish lines on the maxillary first premolar. 30 sound maxillary first premolars were selected and then storaged in 5% NaOCl and saline. 15 teeth were performed preparation for each group(1.0mm rounded shoulder, 0.5mm chamfer). After 30 stone dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the natural teeth. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co., Germany)was used to measure the fracture strength, with stress loading on the occlusal surface between buccal and lingual cusp. And also, three-dimensional finite element model was used to measure the stress distribution with two types of the finish lines(1.0mm rounded shoulder, 0.5mm chamfer) and two loading conditions(both buccal and lingual cusp inclination, lingual cusp inclination only). The result of the this study were as follows. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(842N) showed higher value than that of the chamfer(590N) (p<0.05). In the three dimensional finite element analysis of all ceramic crown, metal die and natural teeth model did not show any differences in stress distribution between finish lines. Generally, when force was loaded on the occlusal inclination of buccal and lingual cusp, the stress was concentrated on the loading point and the central groove of occlusal surface. When force was loaded only on the occlusal inclination of lingual cusp, the stress was concentrated on the lingual finish line and loading point.

A STUDY ON THE STAIN RESISTANCE OF DENIAL CERAMICS FOR ALL CERAMIC CROWN (전부도재관용 도재의 염색 저항성에 관한 연구)

  • Son, Oe-Soo;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.416-424
    • /
    • 1999
  • Simulation of naturally appearing enamel in fixed prosthodontics could be achieved with all ceramics. The purpose of this study was to investigate the stain resistance of 4 different all ceramics materials (In-ceram, IPS Empress, Celay, Vintage). Forty specimens were prepared using manifacture's instruction and the samples were divided into two groups. The specimens for one group were glazing and those for other group were ground to remove the glazing layer. All specimens were immersed in methylene-blue for 24hours. The color values for each specimen was measured with colorimeter (Mode Tc-6Fx, Tokyo Denshoku Co.) prior to and after immersion in methylene-blue. The following conclusions were drawn from this study. 1 The stain resistance of glazing ceramics was higher than that of unglazing ceramics. 2. The changes of ${\Delta}E^*$\;and\;L^*$ values were revealed in Vintage and unglazing Celay. 3. The changes of $a^*$ values were revealed in unglazing vintage, Celay, In-ceram. 4. The changes of $b^*$ value were revealed in Vintage, IPS Empress and unglazing Celay.

  • PDF

Fracture strength of zirconia ceramic crowns according to tooth position (치아 부위에 따른 지르코니아 도재관의 파절강도)

  • Lee, In-Seob;Kim, Jeong-Mi;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia ceramic crowns according to tooth position. Material and methods: After 10 metal dies were made for each group, the zirconia ceramic crowns were fabricated using CAD/CAM system ($Lava^{TM}$ All-Ceramic System) and each crown was cemented on each metal die with resin cement (Rely $X^{TM}$ Unicem). The cemented zirconia ceramic crowns mounted on the testing jig were inclined with 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The fracture strength of the zirconia ceramic crown in the lower 1st molar (2963 N) had the highest and that in the lower central incisor (1035 N) had the lowest. 2. The fracture strength of zirconia ceramic crown was higher than that of the IPS Empress crowns in all tooth position. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the long axis of the crowns. 4. There were no significant differences on the fracture strength of the zirconia ceramic crowns according to tooth position except in premolar group. Conclusion: Within the limitations of this study, the results suggested that strength of zirconia ceramic crown is satisfactory for clinical use.

THE FRACTURE RESISTANCE AND STRESS DISTRIBUTION OF ALL CERAMIC CROWNS WITH TWO TYPES OF FINISH LINE ON MAXILLARY CENTRAL INCISOR (상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Ki Tae-Seok;Kim Kyea-Soon;Lee Jin-Han;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.405-420
    • /
    • 2003
  • Purpose : The purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown. and 0.5mm width chamfer finish lines on the maxillary central incisor. Material and method : After 15 metal dies were made for each group, the IPS Empress all ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the metal die. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co. Germany)was used to measure the fracture strength with loading on the incisal edge. And also, three-dimensional finite element stress analysis was used to measure the stress distribution with the various types of the finish lines(1.0mm width rounded shoulder, 0.5mm width chamfer), the loading site(incisal edge, incisal $\frac{1}{3}$) and the type of loading(concentration loading, distribution loading). Results and conclusion : 1. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(876N) and the mean fracture strength of chamfer(882N) did not skew any significant difference between each other(p>0.05). 2. The stress distribution of all ceramic crown in three dimensional finite element analysis showed concentration aspect at loading point and cervical area or labial surface. 3. In metal die, there were no differences in stress distribution between finish lines, but in natural teeth model, chamfer finish line showed higher stress than rounded shoulder finish line. 4. When force was loaded on the incisal edge the stress was concentrated on the incisal edge and the cervical area of labial surface. When force was loaded on the incisal $\frac{1}{3}$, the stress concentrated on the cervical area of labial surface and the cingulum area. 5. Generally, natural teeth model showed higher and various stress than the metal die.

EFFECT OF DENTIN DESENSITIZERS ON SHEAR BOND STRENGTH OF RESIN CEMENTS (상아질 지각완화제가 레진시멘트의 전단결합강도에 미치는 영향)

  • Lee Ho;Jin Tai-Ho;Son Oe-Soo;Ahn Hee-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.365-373
    • /
    • 2002
  • The purpose of this study was to investigate the effects of desensitizer on shear bond strength of adhesive resin cements for all ceramic crown. For this study, Gluma $desensitizer^{(R)}$(Heraeus Kulzer, Germany) and MS $Coat^{(R)}$(Sun medical, Japan) were used as desensitizer, and Bistite $II^{(R)}$ resin cement(Tokuyama, Japan) and Variolink $II^{(R)}$ resin cement (Ivoclar, Liechtenstein) were used. IPS Empress ceramics were bonded to dentin surfaces after application of desensitizer and shear bond strength of specimens were measured using UTM(Zwick 1456 41. Zwick, Germany) at a crosshead speed of 1mm/min. The obtained results were as follows : 1. The shear bond strength of both resin cements were not affected by Gluma $desensitizer^{(R)}$ containing HEMA 2. The shear bond strength of Bistite $II^{(R)}$ resin cement was significantly decreased by MS $Coat^{(R)}$. 3. The failure mode in MS $Coat^{(R)}-Bistite \;II^{(R)}$ group was mainly adhesive type between dentin and resin cement. but that of Gluma $desensitizer^{(R)}$-Variolink $II^{(R)}$ group was mainly mixed type, combined adhesive failures between dentin and resin cement or porcelain and resin cement.

A STUDY ON THE FLEXURAL STRENGH OF HEAT-PRESSED CERAMICS ACCORDING TO SPRUE DESIGNS (주입선 설계에 따른 Heat-pressed ceramic의 파절강도에 관한 연구)

  • Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.130-143
    • /
    • 1997
  • A heat-pressed technique(IPS-Empress, Ivoclar) has been described to construct single unit crown, inlay/onlay and veneers using a partially pre-cerammed and pre-colored glass-leucite ingot that has the greateast strength by the combination of heat-pressed procedure through the smalldiameter sprue and heat treatment procedure. The purpose of this study was to evaluate the flexure strength of a heat-pressed ceramic material(IPS-Empress) without simulated firing treatments according to pontic designs. Two groups of 9 disks(1.4mm thick, 14mm in diameter) each using two types of sprues with different diameters($({\Phi}2.8\;,{\Phi}1.8)$) and numbers were prepared. The specimens were mounted in the testing jig. The flexural strengths were determined, by means of the bi-axial bending test, by loading the center of disk to failure using a universal testing machine(Zwick 145141, Zwick, Germany) at a cross-head speed of 1.0 mm/min. The means flexural strength value of one group using a sprue with ${\Phi}2.8$ was $140.4{\pm}8.0Mpa$. That of the other group using two sprues with ${\Phi}1.8$ was $151.8{\pm}10.3Mpa$. After analysis, results showed that there was a statistical difference between groups(t=2.33m p<0.05). No clnical implications were drawn from these data because of absence of simulated firing treatment.

  • PDF

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.