• Title/Summary/Keyword: IOR

Search Result 51, Processing Time 0.03 seconds

Performance Analysis of Intake Screens in Power Plants on Mass Impingement of Marine Organisms (발전소 취수구에 대량으로 유입하는 해양생물에 대한 스크린 설비의 성능분석)

  • Lee, Jae-Hac;Choi, Hyun-Woo;Chae, Jin-Ho;Kim, Dong-Sung;Lee, Seung-Baek
    • Ocean and Polar Research
    • /
    • v.28 no.4
    • /
    • pp.385-393
    • /
    • 2006
  • Screening performance of the existing intake screens (drum and travelling screen) on mass impingement of marine animals, a euphausiid, Euphausia pacifica and a scyphozoan medusae, Aurelia aurita that have often clogged intake screens of the Uljin Nuclear Power Plant, was tested. The maximum tolerable densities of marine animals in the inflowing seawater upon the screen were estimated with two different approaches. First the maximum density of jellyfish was calculated from (1) passing amount of seawater per unit time through the screens and (2) the covered area of animals on the screens clogged. The maximum density of krill tolerable in the drum screen was cited from a simulated record of Uljin NPP, then those in the travelling screens were also calculated using the data of drum screen and ratio of seawater amount passing through the screens under the condition of 0.5m water column (W.C.) of the differential pressure (AP) produced by screens, an established permissible limit of ${\Delta}P$. Secondly, the screening performances were also tested by hydrodynamic measurements with various screen models in a circulating water channel equipped with a speed-controlling pump and a differential pressure gauge. From the first approach, the maximum tolerable densities of drum and travelling screen were calculated as 2.0 and $1.5ind/m^3$ for the Jellyfish and 900 and $680ind./m^3$ for the euphausiid, respectively. These densities estimated from the second approach were 2.1 and $0.8ind/m^3$ for the jellyfish and 1059 and $504ind/m^3$ for the euphausiid, respectively. These estimates were compared with the data from historic clogging events to evaluate the practical performance of these intake screens. The comparisons suggest a newly improved intake-screen of which performance should be at least seven times (approximately) better than the existing ones ior the krill and 3.2 times for the jellyfish, respectively, for preventing mass impingement, and for maintaining the condition of the differential pressure between the screens below 0.3 m W.C.

Evaluation of 358 Mandibular Poster ior Implants: A 3-year Retrospective Study (하악 구치부위에 식립한 358개 임플란트의 생존율에 대한 3년간 후향적 연구)

  • Yoon, I-Kwon;Lee, Gi;Lee, Dong-Un;Choi, Ju-Young;Yu, Jeong-A;Park, Pil-Gyu;Kim, Jeong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.59-68
    • /
    • 2010
  • Recently, dental implants extensively inserted on edentulous area show highly clinical success rate. However, clinicians cannot exclude the possibility of failure and it often unexpectively occures. Many possible factors associated with failure of dental implants have been reported but controversy exists over the extent to them. In this study, we collected 212 patients who had been inserted 358 dental implants on mandibular premolar and molar area from 2005 to 2006. The survival rate of fixtures was recorded according to age of patients, implantation site, implant system, diameter and length of fixtures. Multi-variable analysis using SPSS chi-square test was operated to verify relation of each factors and survival rates. Accumulative survival rate was 98.3% for 3 years. Only diameter of fixtures was related to the implant survival rate. This may be thought that wider fixtures had been chosen to rescue implants or used in sites of poor bone quality. Further continuous study will be needed for direct guidance associated with survival rate of implants.

A Study on Crystallographic and Mossbauer Spectroscopic Properties of Magnetic Oxide (산화물 자성체의 결정학적 및 뫼스바우어 분광학적 특성 연구)

  • Park, Seung-Han
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.701-706
    • /
    • 1999
  • The crystal structure and magnetic properties of magnetic oxide system (F $e_2$ $O_3$)$_{5}$(A $l_2$ $O_3$)$_{4-x}$(G $a_2$ $O_3$)$_{x}$)SiO has been studied using X-ray diffraction and Mossbauer spectroscopy The changes of magnetic structure by the Ga ion substitution and the temperature variation have been investigated using Mossbauer spectroscopy, and the results are compared with those of the SQUIB measurements. Results of X-ray diffraction indicated that the crystal structures of the system change from a cubic spinel type to an orthorhombic via the intermediate region. This magnetic oxide system seems to be new kind of spinel type ferrites containing high concentration of cation vacancies. Various and complicated Mossbauer spectra were observed in the samples (x>0.2) at temperatures lower than room temperature. This result could be explained by freezing of the superparamagnetic dusters. On cooling and substitution, magnetic states of the system show various and multicritical properties. Unexpected dip in magnetization curves below 50K was observed in SQUID measurements. It was interpreted as an effect of spin canting including spin freezing or collective spin behavior.ior.r.

  • PDF

Studies on Oocyte Activation Regimen for Nuclear Transfer in Hanwoo(Korean Cattle) (핵이식을 위한 한우 난자 활성화 처리방법에 관한 연구)

  • 임기순;양보석;박성재;양병철;장원경;박창식
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.3
    • /
    • pp.281-288
    • /
    • 2000
  • This experiment was carried out to investigate the optimal activation condition for parthenogenetic development. In order to activate oocytes at 22 h post onset of maturation, the oocytes were subjected to 5 $\mu$M ionomycin(I) for 5 min ,10 $\mu$M calcium ionophore(Ca) for 5 min, 2 mM 6-dimethylamino-purine(DMAP) for 3 h and 10 $\mu\textrm{g}$/$m\ell$ cycloheximide(CH) for 6 h alone or in combination. The activated oocytes were cultured in modified CR$_1$aa at 5% $CO_2$, 5% $O_2$, 90% $N_2$. l. The cleavage rates after 48 h culture of oocytes treated with I, Ca, DMAP and CH were 12.7%, 14.1%, 28.9% and 22.9%, respectively. There was no blastocyst formation. 2. The cleavage rates after 48 h culture of oocytes treated with I + DMAP, I + CH, Ca + DMAP and Ca + CH were 96.9%, 82.1%, 93.1% and 34.7%, respectively. Developmental rates to blastocysts were 10.4%, 5.3%, 17.6% and 7.1 %, respectively. When oocytes were treated with Ior Ca followed by DMAP, the blastocyst formation rate was significantly higher than other groups(P <0.05). 3. According to single activation treatment, pronucleus formation rates were 5.4%, 3.6%, 28.3% and 28.8%, respectively, Whereas, all oocytes treated with the combined activation agents formed 100% pronucleus.

  • PDF

MANDIBULAR DIFFERENTIAL PREMOLAR EXTRACTI0N IN GROWING PATIENTS (성장기 환자에서 하악의 차등적 소구치 발치)

  • Kim, Do-Hoon;Sung, Sang-Jin;Moon, Yoon-Shik
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.1-13
    • /
    • 2001
  • The extraction lot orthodontic treatment can be adopted for aligning crowded dentition, improving facial esthetics and solving a skeletal discrepancy as alternative for a surgical option. Mandibular second premolar extraction was often selected as treatment plan when there we very little or no space shortage in lower arch or limited retraction of the lower incisors was required. The primary object of this study was evaluate a pretreatment condition and examine the amount of tooth movement ior a mandibular second premolar extraction in growing patients. Pretreatment and posttreatment lateral cephalograms of 14 cases that had their four first premolar extracted (4/4 group), 15 cases with upper first and lower second premolar extraction (4/5 group) were selected. Structural method superimposition was conducted to evaluate a difference of dental change between 4/4 and 4/5 group. The results were as follows, 1. Pretreatment factor for 4/4 extraction or 4/5 extraction choice included maxillary incisor axis to occlusal plane, Class II molar relationship, IMPA and interincisal angle. 2. The amount of molar anterior movement in 4/5 group was greater than that of 4/4 group(p<0.05). 3. There was no significant difference between 4/4 group and 4/5 group in aspects of maxillary tooth movement(p<0.05).

  • PDF

Purification and Properties of ${\beta}-Mannanases$ from Germinated Guar Bean (${\beta}-Mannanase$ 군(群)의 정제(精製) 및 그들의 성질(性質)에 관(關)한 연구(硏究))

  • Lee, Su-Rae
    • Applied Biological Chemistry
    • /
    • v.7
    • /
    • pp.1-13
    • /
    • 1966
  • 1) Three ${\beta}-1$, 4-mannanases were isolated from germinated guar bean through extraction, ammonium sulfate fractionation, column chromatography on cellulose derivatives and gel filltration on Sephadex G-100. They were designated as ${\beta}-1$, 4-mannanase A,B and C, respectively, in the order of isolation. 2) These enzymes were different in several aspects such as pH optimum, effect of metal ions, adsorbability on cellulose derivatives, molecular weight, Michaelis constant toward reduced ivory nut mannan A, mode of action and extent of hydrolysis of the mannan. 3) ${\beta}-1$, 4-Mannanases A and C were proposed to be two different endo-enzymes of random-splitting type producing a series of oligosaccharides from ${\beta}-1$, 4-mannans. ${\beta}-1$, 4-Mannanase B was suggested to be possibly an exe-type enzyme catalyzing a stepwise splitting from the non-reducing end of ${\beta}-1$, 4-mannans to produce mannose. 4) Guaran was subjected to hydrolysis by the purified enzymes and the consequence was discussed in connection with structural requirements of the enzymes toward substituted ${\beta}-1$, 4-mannans and their role in germinating guar seeds.

  • PDF

Radiosurgery with Linac Based Photon Knife in Cerebral Arteriovenous Malformation (선형가속기를 이용한 Photon Knife 방사선수술에 의한 뇌동정맥기형의 치료)

  • Kim, Jin-Hee;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • Purpose : The purpose of this study was to analyze the effect of a Linear accelerator based Photon Knife Radiosurgery System developed by the staff of Keimyung University Dongsan Medical Center for the treatment of cerebral arterlovenous malformation Material and Methods : Between December 1993 and October 2000, 30 patients with cerebral arteriovenous malformation (AVM) were treated with the Linac based Photon knife Radlosurgery System In the Department of Therapeutlc Radiology at Keimyung University Dongsan Medical Center. The median age was 34, ranging from 7 to 63 years, with a 2 : 1 male to female ratio. The locations of the AVM nidi were the frontal lobe (motor cortex), parletal lobe, and the thalamus, In that order. The diameters of the AVM nidi ranged 1.2 to 5.5 cm with a mean on 2.9 cm, and target volumes of between 0.5 and 20.5 cc, with a mean of 5.8 cc. The majority of patients received radiation doses of between 1,500 and 2,500 cGy, w14h a mean of 2,000 cGy, at 80% the isodose line. Twenty-five patients were treated with one isocenter, 4 with two, and 1 with four. The follow-up radiological evaluations were peformed with cranial computed tomogram (CT) or MRI between 6 month and one year interval, and if the AVM nidus had completely disappeared in the CT or MRI, we confirmed thls was a complete obliteration, with a cerebral or magnetic resonance angiogram (MRA). The median iollow-up period was 39 months with a range of 10 to 103 months. Results : Twenty patients were radloiogicaiiy followed up ior over 20 months, with complete obliteration observed in 14 (70%). According to the maximal diameter, all four of the small AVM (<2 cm) completely obliterated, 8 of the 10 patients with a medium AVW (2~3 cm) showed a complete obliteration, and two showed partial obliteration. Among the patients with a large AVM (>3 cm), only one showed complete obliteration, and S showed partial obliteration, but 3 oT these underwent further radiosurgery 3 years later. One who followed up for 20 months fellowing further radiosurgery eventually showed complete obliteration. Ten patients with seizure symptoms had no recurrent seizure due to radiosurgery and medication. One of the eleven patients who suffered intracranlal bleeding developed further bleeding at 9 and 51 months fellowing the radiosurgery although complete obliteration was eventually observed and the patient was managed in hospital then recovered. No patient suffered severe complications fellowing the radiosurgery. Conclusion : The radiosurgery with Linac-based Photon knife radiosurgery system, developed by the staff at our hospital, is a safe and effective treatment for AVM patients having diameters or volumes of less than 3 cm or 10 cm$^{3}$, respectively, located In Inoperable areas or who refused neurosurgery. We suggest that staged AVM radiosurgery may initially be considered, if the AVM target volume is above 10 cm$^{3}$

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.

Changes in midpalatal suture area and adjacent periodontal tissues of individual tooth following rapid palatal expansion in young adult dogs ; Histomorphologic and immunohistochemical study (유성견 급속 구개확장시 정중구개봉합부 및 치아주위 조직 변화에 관한 조직형태학적 및 면역조직화학적 연구)

  • Lee, Ju-Young;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.317-333
    • /
    • 2000
  • The purpose of this study was to determine the proliferative activity of the osteoblasts and fibroblasts in the midpalatal area and to investigate the adjacent periodontal tissues of individual tooth following rapid expansion of the palate. Ten young adult dogs, aged approximately ten months, were used in the experiment. The experimental design was consisted of 1 week expansion group(Group E1, 3 dogs), 2 week expansion group(Group E2, 3 dogs), 2 week expansion and 2 week retention group(Group E3, 3 dogs), and control group(Group C, 1 dog). For each group, expansion screw was activated one time per day(1/4 turn;$90^{\circ}$) following Hyrax-screw application. The experimental animals in each group were sacrificed at 1, 2 and 4 weeks following palatal expansion. Maxillary tissue blocks were obtained and prepared ior the histomorphologic and immunohistochemical studies. Light mcroscope, polarizing microscope, and soft X-ray apparatus were used in this study, and following results were obtained. 1. In polarizing microscopic study, the expansion groups(E1 & E2) showed blue color representing bone resorption and new bone formation in midpalatal suture area. E3 groups skewed less blue color compared to the E1 and E2 group. But yellow color increased by calcification in the E3 groups. 2. Immunohistochemical study revealed that positive responses of the osteoblasts to PCNA and undifferentiated fibroblasts to EGF in E1 group were somewhat increased. Positive response to PCNA and EGF were increased in fibroblasts and the osteoblasts forming new bone in E2 group. In E3 group, the positive response cell concentrated the periphery of edge of palatal process in both PCNA and EGF. 3. Throughout the expansion period(E1 & E2), light microscopic study showed the edges of the extensive resorption and new palatal processes, indicating bone remodeling within the suture. E3 group exhibited less remodeling of midpalatal suture area. E2 group and E3 group showed cementum formation and resorption at the apex of 3rd premolar and 1st molar E3 group exhibited extensive hyalinized zone on the cervical portion of buccal side of 1st molar. 4. Soft X-ray analysis of E1 group showed hypomineralized defect and microfractures in various parts of the suture areas when compared with control animals. There was no significant difference in the degree of mineralization in the midpalatal suture region between the C and E3 groups. Tooth axis showed tipping of 3rd premolar and 1st molar in the E2 group and E3 group. Based upon these experimental results, it is concluded that the undifferentiated mesenchymal cells always presented in midpalatal suture area following RPE. Differentiated osteoblasts and fibroblasts possess proliferating cellular activity until the 2 week retention period. The posterior teeth are tend to tip buccally as RPE force applied. Retention group exhibited irreversible response with severe hyalinized zone on the buccal surface of the first molar.

  • PDF

User Centered Interface Design of Web-based Attention Testing Tools: Inhibition of Return(IOR) and Graphic UI (웹 기반 주의력 검사의 사용자 인터페이스 설계: 회귀억제 과제와 그래픽 UI를 중심으로)

  • Kwahk, Ji-Eun;Kwak, Ho-Wan
    • Korean Journal of Cognitive Science
    • /
    • v.19 no.4
    • /
    • pp.331-367
    • /
    • 2008
  • This study aims to validate a web-based neuropsychological testing tool developed by Kwak(2007) and to suggest solutions to potential problems that can deteriorate its validity. When it targets a wider range of subjects, a web-based neuropsychological testing tool is challenged by high drop-out rates, lack of motivation, lack of interactivity with the experimenter, fear of computer, etc. As a possible solution to these threats, this study aims to redesign the user interface of a web-based attention testing tool through three phases of study. In Study 1, an extensive analysis of Kwak's(2007) attention testing tool was conducted to identify potential usability problems. The Heuristic Walkthrough(HW) method was used by three usability experts to review various design features. As a result, many problems were found throughout the tool. The findings concluded that the design of instructions, user information survey forms, task screen, results screen, etc. did not conform to the needs of users and their tasks. In Study 2, 11 guidelines for the design of web-based attention testing tools were established based on the findings from Study 1. The guidelines were used to optimize the design and organization of the tool so that it fits to the user and task needs. The resulting new design alternative was then implemented as a working prototype using the JAVA programming language. In Study 3, a comparative study was conducted to demonstrate the excellence of the new design of attention testing tool(named graphic style tool) over the existing design(named text style tool). A total of 60 subjects participated in user testing sessions where their error frequency, error patterns, and subjective satisfaction were measured through performance observation and questionnaires. Through the task performance measurement, a number of user errors in various types were observed in the existing text style tool. The questionnaire results were also in support of the new graphic style tool, users rated the new graphic style tool higher than the existing text style tool in terms of overall satisfaction, screen design, terms and system information, ease of learning, and system performance.

  • PDF