• 제목/요약/키워드: IOL

검색결과 35건 처리시간 0.025초

도시 대기오염물중 다환방향족 탄화수소의 배출원 규명을 위한 화학물질 수지모델의 적용 (Application of chemical Mass Balance Model for the Source Apportionment of Polynuclear Aromatic Hydrocarbons in Urban Atmosphere)

  • 구자공;서영화
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.229-239
    • /
    • 1992
  • A receptor model application was performed by using a chemical mass balance (CMB) model to identify and apportion the specific source of airborne organic pollutants, particularly polynuclear aromatic hydrocarbons (PAHs). Source profiles of PAHs produced from the combustion of fossil fuels for CMB modeling were prepared by measuring them in emission gases. The emission sources which were examineed for the development of PAH source profiles are a coal-fired furnace using Yontan, a bunker-C iol heating boiler, and gasoline-and diesel engine automobiles. The ambient concentrations of PAHs were determined at four sites in Daejon city in 1991 with a seasonal variation. Wintertime air samples contained more extractable organic matter than summertime samples. The results of CMB modeling were various depending on the sampling sites and seasons, but the emission from bunker-C oil heating boliers was the predominant factor to affect local air quality throughout the year.

  • PDF

굴절부등안과 동등안의 양안 굴절요소 차이 비교 (A Comparison of Refractive Components in Anisometropia and Isometropia)

  • 심현석;심준범;김은석
    • 한국안광학회지
    • /
    • 제16권2호
    • /
    • pp.187-193
    • /
    • 2011
  • 목적: 굴절부등안과 동등안에서 안축장, 각막굴절력, 전방깊이, 안축장/각막곡률반경 비 등의 차이를 비교하여 굴절요소와 굴절부등의 연관성을 알아보고자 하였다. 방법: 본 연구는 2010년 8월부터 2010년 9월까지 광주광역시 B병원에서 굴절검사를 통해 안경과 콘택트렌즈 처방을 받고자 하는 환자 중 2.7~15.3세 총 83명, 굴절부등안 45명(90안)과 굴절동등안 38명(76안)을 대상으로 하였다. IOL Master를 이용 안축장과 전방깊이, 각막곡률반경, 각막굴절력을 측정하였고, Auto-refractometer를 이용하여 굴절이상을 측정하였다. 결과: 굴절부등안은 안축장이 유의하게 차이가 났으며, 굴절부등안과 동등안에서 굴절이상, 안축장, 안축장/각막곡률반경 비 등이 통계적으로 유의한 차이가 있었다. 굴절부등을 일으키는 요인은 45명 전원이 안축장으로 나타났다. 굴절요소 중 안축장, 안축장/각막곡률반경 비는 상관성이 높았고, 각막굴절력은 상관이 없었으며 전방깊이는 상관성이 적은 것으로 나타났다. 결론: 굴절이상은 대부분 안축장에 의한 축성 비정시이었으며, 굴절부등의 원인도 다른 굴절요소와는 상관성이 적고, 안축장 차이가 주된 원인임을 알 수 있었다.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

양안 굴절이상 차이에 의한 안광학상수 변화도 분석 (Analysis on Ocular Components Variation with the Difference of Both Refractive Errors)

  • 이혜정;이은희;정미아
    • 디지털융복합연구
    • /
    • 제14권11호
    • /
    • pp.435-440
    • /
    • 2016
  • 양안 굴절이상 차이에 의한 안광학상수 변화도 분석을 통한 양안 굴절이상 차이의 특성을 이해 할 수 있는 기초자료를 제공하고자 하였다. 20-59세의 건강한 성인 100명을 대상으로 KR-8800을 이용하여 등가구면 굴절력과 각막곡률 반경을, IOL Master를 사용하여 안축장길이와 전방깊이를 측정하였으며, 측정값의 차이는 우안 측정값-좌안 측정값의 차이값에 절대 값을 구하여 사용하였다. 전체 대상자의 등가구면 굴절력은 $-1.83{\pm}2.17D$이고, 안축장길이는 23.00~24.99mm, 각막곡률반경은 7.50~7.89mm, 전방깊이는 3.60~4.09mm의 범위에서 가장 많았다. 양안 등가구면 굴절력 차이에 따른 양안 안축장길이 차이와 양안 전방깊이의 차이가 유의한 상관관계가 있었다. 또한, 양안 굴절력 차이에 의한 양안 안축장 길이 차이가 가장 크고, 가장 높은 상관성이 있었다. 양안 굴절력 차이는 안광학 상수와 밀접한 관계가 있고, 양안 굴절력 차이에 의하여 여러 가지 시기능 문제가 발생 할 수 있으므로, 양안 굴절이상 차이에 따른 요인별 분류를 통한 융복합 연구가 필요하다.

노안을 위한 정밀 모형안 설계 (Optical Models of the Finite Schematic Eyes for Presbyopia)

  • 박상배
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.439-447
    • /
    • 2008
  • 노안환자를 위한 백내장 수술, 노안교정을 위한 각막절제술, 노안교정용 콘택트렌즈 및 안경착용과 같은 다양한 조건하에서 정확하게 시력과 상질을 형상화하는 정밀 노안 모형안이 필요하다. 노안에 대해 최근에 발표된 임상 자료들을 이용하여 광학적, 해부학적으로 실안에 근접하며, 노안을 위한 새로운 정밀 모형안을 설계하였다. 연령의 증가에 따라 달라지는 안 매개변수들을 각각 4개의 연령대별로 다르게 적용하였다. 새 모형안에는 알파각, 편심동공, 비구면 GRIN 수정체 및 비구면 망막 면을 적용하였다. 본 연구에서 제시된 모형안들은 노안을 위한 저시력 보정용구, 누진가입도렌즈, 인공수정체 그리고 콘택트렌즈와 같은 시기광학계의 설계는 물론 임상적으로 망막 상의 질을 평가하는데 유용하게 적용될 수 있을 것이다.

주관적 향의 선호도와 뇌파 반응과의 상관관계 (Correlation Between Subjective Preference of Essential Oils and EEG Response)

  • 민병찬;정순철;한정수;변증남;김철중;김준수
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 추계학술대회 논문집
    • /
    • pp.38-43
    • /
    • 2000
  • In this present study, the correlation between subjective preference of essential odors and EEG response were investigated quantitatively. EEG signals were measured from 19 electrodes according to the International 10-20 system (Fpl, Fp2, F2/4, F7/8, Fz, C3/4, Cz, P3/4, Pz, T3/4, T5/6, Ol/2) from 8 healthy males subjects in four odor conditions. Four odor conditions (Rose oil bulgarian, Lemon oil misitano, Jasmin abs, Laverder iol france (KIMEX co. Ltd)) were applied for each subject in the experiment. Through the subjective evaluation, the most pleasant odor for each subject was determined. The power spectrum of ${\alpha}$/${\beta}$ of EEG signals from the most pleasant odor was compared with those from the control condition, which has no odor at all. It was observed that the power spectrum of ${\alpha}$/${\beta}$ of EEG from the most pleasant odor was increased significantly on F3, F3, F4,74 comparing to the control condition. This result indicates that the power spectrum of ai${\beta}$ could be a new index for measuring the levels of pleasantness of odors.

  • PDF

CRISPR-Driven Genome Engineering for Chorismate- and Anthranilate-Accumulating Corynebacterium Cell Factories

  • Hye-Jin Kim;Si-Sun Choi;Eung-Soo Kim
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권10호
    • /
    • pp.1370-1375
    • /
    • 2023
  • In this study, we aimed to enhance the accumulation of chorismate (CHR) and anthranilate (ANT), key intermediates in the shikimate pathway, by modifying a shikimate over-producing recombinant strain of Corynebacterium glutamicum [19]. To achieve this, we utilized a CRISPR-driven genome engineering approach to compensate for the deletion of shikimate kinase (AroK) as well as ANT synthases (TrpEG) and ANT phosphoribosyltransferase (TrpD). In addition, we inhibited the CHR metabolic pathway to induce CHR accumulation. Further, to optimize the shikimate pathway, we overexpressed feedback inhibition-resistant Escherichia coli AroG and AroH genes, as well as C. glutamicum AroF and AroB genes. We also overexpressed QsuC and substituted shikimate dehydrogenase (AroE). In parallel, we optimized the carbon metabolism pathway by deleting the gntR family transcriptional regulator (IolR) and overexpressing polyphosphate/ATP-dependent glucokinase (PpgK) and glucose kinase (Glk). Moreover, acetate kinase (Ack) and phosphotransacetylase (Pta) were eliminated. Through our CRISPR-driven genome re-design approach, we successfully generated C. glutamicum cell factories capable of producing up to 0.48 g/l and 0.9 g/l of CHR and ANT in 1.3 ml miniature culture systems, respectively. These findings highlight the efficacy of our rational cell factory design strategy in C. glutamicum, which provides a robust platform technology for developing high-producing strains that synthesize valuable aromatic compounds, particularly those derived from the shikimate pathway metabolites.

LB 초박막을 이용한 전지전자 공업용 MIM소자의 온도변화에 의한 발생전압 특성 (Characteristics of Generated Voltage by Temperature Change of Electrical, Elecrtronic and Industrial MIM Element Using LB Ultra Thin Film)

  • 김병인;국상훈
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권3호
    • /
    • pp.80-87
    • /
    • 1997
  • Polyimide LB막 의 시료 와 {{{{Al/{Al}_{2}{O}_{3}/PI(nL)/Au}}}} 에 대해 전압의 온도특성 실험에서 상부전극과 하부전극간에 일함수차를 발견하였다. Polyimide LB\ulcorner은 Z형으로 누적하거나 , imide화하면 막에 분극이 발생하지 않았다. 또 {{{{{C}_{15} TCNQ}}}} LB 막 시료{{{{Al/{Al}_{2}{O}_{3}/{C}_{15} TCNQ(10L)/Al}}}} 은 상, 하부 전극이 같아 일차함수가 없었으며 막에 분극이 발생하였다. LB 초박막 MIM 소자를 시료로 하여 실험한 결과 수백 mV 이상의 직류가 발생하였으므로 전기.전자 및 정보통신 분야의 산업용 전원으로 이용할 수 있다고 생각한다.

  • PDF

단백질흡착 감소용 하이드로겔의 개발 및 인공수정체로의 적용 (Development of Hydrogel for Decrease Protein Adsorption and Application to Intraocular Lens)

  • 고나영;이현미
    • 대한화학회지
    • /
    • 제62권1호
    • /
    • pp.30-35
    • /
    • 2018
  • 인공수정체로 사용되고 있는 소수성 아크릴 하이드로겔의 단백질 흡착 감소와 기능을 향상시키기 위한 하이드로겔을 제조하여 인공수정체로의 응용성을 살펴보고자 한다. 소수성 아크릴 인공수정체는 ethyleneglycol phenyletheracrylate(EGPEA), Styrene, 2-hydroxyethyl methacrylate(HEMA)를 사용하여 제작하였고 첨가제로 polyvinyl pyrrolidone(PVP)와 2-methacryloyloxyethyl phosphorylcholine(MPC)를 사용하였다. 인공수정체의 물리적 특성을 평가하기 위해 함수율, 습윤성, 광투과율 및 단백질 흡착량을 측정하였다. 첨가제를 넣은 모든 시료의 함수율과 습윤성은 증가하였고 단백질 흡착량은 감소하였다. 특히 MPC가 포함된 시료의 단백질 흡착량은 더욱 감소하였다. PVP와 MPC를 첨가한 소수성 아크릴 하이드로겔은 기본적인 물리적 특성을 가지면서 단백질 흡착을 감소시킴으로써 기능이 향상된 인공수정체로의 응용이 가능하다는 것을 확인하였다.

핵, 피질 그리고 낭 백내장의 굴절이상 전환 (Refractive Error Shift in Nuclear, Cortical, and Subcapsular Cataract)

  • 박상철;이석주;성아영
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.41-45
    • /
    • 2003
  • 노인성 백내장의 세 가지 형태학이 굴절이상에 미치는 영향에 관하여 연구하기 위해 세 가지 형태의 백내장 특성에 따른 구면 굴절력과 원주 굴절력의 변화를 백내장의 형태적인 위치에서 나타내었고 또한 백내장 수술 전후의 안압이 굴절이상에 어떠한 영향을 주는가에 대하여 연구하였다. 등가 구면 굴절력에서 핵 백내장은 근시성 전환, 피질 백내장은 원시성 전환을 보였고 낭 백내장은 양쪽의 전환 폭이 적은 것으로 나타났다. 수정체 내 백액내장의 해부학적 위치를 확인하기 위해 광학단면(세극등)을 이용하여 관찰하였고 굴절이상을 측정하기 위해 타각적, 그리고 자각적 방법을 사용하여 등가 구면 굴절력으로 나타내었다. 안압 측정은 수술전과 수술 후 인공수정체가 삽입된 일주일 뒤에 다사 각각의 상태에서 안압을 자동 안압계를 사용하여 측정하였다. 원주 굴절력의 변화는, 일반적으로 나이가 증가함에 따라 안축의 길이가 감소하는 경향을 보였지만, 백내장의 진행으로 안압이 높아져 안축의 길이가 증가하게되고 그 영향으로 직난시에서 도난시로의 전환에 영향을 주기도 하고 또한 이것이 안압으로 인해 더욱 증가하기도 함을 알 수 있었다.

  • PDF