• 제목/요약/키워드: INTERFACE

검색결과 20,335건 처리시간 0.054초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

거대고리 운반체에 의한 중금속이온의 에멀죤 액체막 수송 (Emulsion Liquid Membrane Transport of Heavy Metal Sons by Macrocyclic Carriers)

  • 정오진
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.223-232
    • /
    • 1995
  • 액체막의 운반체로 사용할 새로운 2개의 거대고리화합물을 합성하였다. 이들 결과들은 이 시스템을 구성하는데 있어서 이론의 응용성을 증명하여 준다. source phase의 공존이온으로서 $SCN^-$,$I^-$$Cl^-$이온을 그리고 receicing phases에서 $S_2O_3^{2-}$$P_2O_7^{4-}$을 이용한 액세막계로서부터 중금속 이온들에 대한 선택적 수송효율을 검토하였다. source phase의 M(II)이 $Cd(SCN)_2$$(P[SCN^-]= 0.40M)$, $Hg(SCN)_2([SCN^-]=0.40M)$, Pd(CN)$([CN^-]= 0.40M)$일때 M(II)의 수송율은 최대값을 나타낸다. 각가의 경쟁 양이온에 대한 Cd(II)이나 Pd(II)은 source phase가 00.3M-$S_2O_3^{2-}$이나 0.3M-$P_2O_7^{4-}$ 일때 가장 잘 분리된다.이 연구의 결과에서, 이 액체막계에서 효과적인 거대고리-매질수송을 하기 위해서는 두개의 규칙이 반드시 필요하다. 첫째, tiluence중으로 $M^{n+}$이온이 효과적으로 추출되고, 즉 만일 $M^{n+}$ 거대고리화합물 상호작용에 대한 logK값과 $M^{n+}$-거대고리화합물($L_1$이나 $L_2$)의 상호작용에 대한 logK값의 비가 충분히 크다면 receiving phase와 toluene의 접촉면으로부터 쉽게 중금속이온($Cd^{2+}$,$Pb^{2+}$$Hg^{2+}$)들이 떨어져 나온다. $L_1$(3,5-benzo-10,13,18,21-tetraoxa-1,7-diazabicyclo(8,5,5)eicosnan)은 $Cd^{2+}$$Pb^{2+}$ 이온과 안정한 착물을 형성한다. 그리고 $L_1$은 수용액중에서 용해하기가 매우 어렵다. 그리고 $Cd^{2+}$$L_1$$Pb^{2+}$$L_1$착물은 $Cd^{2+}-{(S_2O_3)}_2^{2-}$$Pd^{2+}-P_2O_7^{4-}$착물보다 비교적 불안정하다. 다른 한편으로 $Hg^{2+}-L_1$착물의 안정도는 $Hg^2-{2+}-(S_2O_3)_2^{2-}$이나 $Pb^{2+}-P0_2O_7^{4-}$의 그것보다 그리고 $L_2$(5,8,15,18,23,26-hexaoxa-1,12-diazabicyclo(10,8,8)octacosan)의 tuluene에 대한 분배계수는 $L_1$의 그것보다 훨씬 작다. 따라서 $Hg^{2+}$-$L_1$이나 $M^{n+}$이나 $M^{n+}-L-2(M^{2+}=Cd^{2+}, Pb^{2+}$이나 $Hg^{2+})$의 안정도수상수가 매우 큼에도 불구하고 이들 양이온의 수송량은 매우 적다.

  • PDF

소셜미디어 콘텐츠의 오피니언 마이닝결과 시각화: N라면 사례 분석 연구 (Visualizing the Results of Opinion Mining from Social Media Contents: Case Study of a Noodle Company)

  • 김유신;권도영;정승렬
    • 지능정보연구
    • /
    • 제20권4호
    • /
    • pp.89-105
    • /
    • 2014
  • Web2.0의 등장과 함께 급속히 발전해온 온라인 포럼, 블로그, 트위터, 페이스북과 같은 소셜 미디어 서비스는 소비자와 소비자간의 의사소통을 넘어 이제 기업과 소비자 사이의 새로운 커뮤니케이션 매체로도 인식되고 있다. 때문에 기업뿐만 아니라 수많은 기관, 조직 등에서도 소셜미디어를 활용하여 소비자와 적극적인 의사소통을 전개하고 있으며, 나아가 소셜 미디어 콘텐츠에 담겨있는 소비자 고객들의 의견, 관심, 불만, 평판 등을 분석하고 이해하며 비즈니스에 적용하기 위해 이를 적극 분석하는 단계로 진화하고 있다. 이러한 연구의 한 분야로서 비정형 텍스트 콘텐츠와 같은 빅 데이터에서 저자의 감성이나 의견 등을 추출하는 오피니언 마이닝과 감성분석 기법이 소셜미디어 콘텐츠 분석에도 활발히 이용되고 있으며, 이미 여러 연구에서 이를 위한 방법론, 테크닉, 툴 등을 제시하고 있다. 그러나 아직 대량의 소셜미디어 데이터를 수집하여 언어처리를 거치고 의미를 해석하여 비즈니스 인사이트를 도출하는 전반의 과정을 제시한 연구가 많지 않으며, 그 결과를 의사결정자들이 쉽게 이해할 수 있는 시각화 기법으로 풀어내는 것 또한 드문 실정이다. 그러므로 본 연구에서는 소셜미디어 콘텐츠의 오피니언 마이닝을 위한 실무적인 분석방법을 제시하고 이를 통해 기업의사결정을 지원할 수 있는 시각화된 결과물을 제시하고자 하였다. 이를 위해 한국 인스턴트 식품 1위 기업의 대표 상품인 N-라면을 사례 연구의 대상으로 실제 블로그 데이터와 뉴스를 수집/분석하고 결과를 도출하였다. 또한 이런 과정에서 프리웨어 오픈 소스 R을 이용함으로써 비용부담 없이 어떤 조직에서도 적용할 수 있는 레퍼런스를 구현하였다. 그러므로 저자들은 본 연구의 분석방법과 결과물들이 식품산업뿐만 아니라 타 산업에서도 바로 적용 가능한 실용적 가이드와 참조자료가 될 것으로 기대한다.

수자원 분야 공익형 기술가치평가 시스템에 대한 연구 (A Study on Public Interest-based Technology Valuation Models in Water Resources Field)

  • 류승미;성태응
    • 지능정보연구
    • /
    • 제24권3호
    • /
    • pp.177-198
    • /
    • 2018
  • 최근 경제재로서 수자원(Water Resources)의 속성이 공공재 성격을 동시에 띠면서 수자원기술의 측정과 성과 관리 체계를 확보하고 활용해야 할 필요성이 제기되고 있다. 그 동안 수자원기술의 평가는 대부분 순현재가치(NPV)나 비용편익효과(B/C)를 바탕으로 경제성 평가(Feasibility Study) 혹은 기술(환경)영향평가(Technology Assessment)로 수행되어 왔으며, 연구성과의 확산과 피드백을 받을 수 있는 기술 기반 사업의 경제적 가치를 객관적으로 평가하는 모델은 체계화되지 않았다. 그리하여, 본 연구에서는 K-water(한국수자원공사)가 담당하고 있는 수자원분야의 기술적 특성에 적합한 기술평가 체계를 구축할 필요성을 느끼고, 공익형 수자원기술에 대한 기술가치평가 모델을 개발하여 사례를 실증하고자 한다. 본 연구에 적용된 K-water 평가대상기술은 공공재로서, 사회전반에 기여한 가치 및 성과를 측정하고 관리할 수 있는 도구로 활용 가능하다. 예를 들면, 사회전반에 기여한 가치를 산출하여, 편익의 파급효과에 대한 성과 홍보자료, 혹은 비용 투입 당위성에 대한 근거자료로 활용할 수 있고, 공공기술의 특성상 대규모 연구개발 투입 비용에 대한 정당성을 확보할 수 있다. 따라서, 공공재를 다루는 한국의 대표적 공기업인 K-water가 사업 운영상의 전략을 수립하고 투입개발 비용에 대한 성과산출 근거 기반을 구축할 수 있을 것으로 판단된다. 본 고에서는 K-water가 담당하고 있는 수자원분야의 기술적 특성에 적합한 기술평가 체계를 기반으로, 공익형 수자원기술에 대한 기술가치평가 모델을 개발하여 사례를 실증하였다. 특히, 일본 산업기술종합연구소(AIST)의 평가방법론을 활용하여 연관 편익항목을 기준으로 비용계정에 매칭시킨 후, 기존의 비용-편익 접근법과 FCF(Free Cash Flow)법의 평가체계를 활용하는 'K-water 고유모델'을 제시하였으며 이를 통해 K-water 연구성과 관리체계 상의 파이프라인을 구축하는 동시에 "해수담수화" 관련 기술에 대한 검증을 수행하였다. 수자원 분야 기술의 특성을 반영한 웹기반 가치평가시스템의 설계 구성로직과 평가프로세스를 분석하며, 기술통합관리시스템 상의 공익형 및 수익형 기술가치를 산출하기 위한 각 모델별 참조정보 및 DB 연계로직도 살펴본다. 종래의 타 분야 기술가치평가 시스템이 지닌 재무적 데이터 기반의 사업가치 산출로직에 수자원 특성이 반영된 정성평가지표의 정량화 지수를 함께 반영한 하이브리드형 평가모듈과 실제 웹기반 평가의 UI 구성화면을 검토한다. K-water의 가치평가 모형은 공익형과 수익형 수자원 기술을 구분하여 평가하게 되는데, 먼저 수익형 기술가치평가는 "기술의 경제성"이라고 하는 특성상 외부 산업유형의 수익(Profit)특성을 반영하여 화면을 설계 가능하다. 예를 들어 K-water 기술인벤토리 수도부문 기술은 수처리 멤브레인과 같이 수익 지향 기술이 다수 분포된다. 반면에, 공익형 기술가치평가는 공공의 편익(Benefit)과 비용(Cost)특성을 반영하여 화면을 설계하게 되는데, 댐과 같이 편익을 지향하는 기술을 평가하는데 활용된다. 또한 본 고에서 제시된 비용-편익 기반의 공익형 기술가치평가 모형(K-water 고유 평가모델)에 대한 적정성 검토를 위해 사회적 수명(20년)을 지닌 수자원 기술의 편익흐름 추정으로부터 실제 사례에 적용해 보았으며, 향후에는 다양한 사업환경 특성을 반영한 비즈니스 모델별 평가모형 검증을 추가적으로 수행하고자 한다.

알칼리 처리된 타이타늄 표면에 대한 골아 유사세포의 세포 활성도 (Cellular activities of osteoblast-like cells on alkali-treated titanium surface)

  • 박진우;이덕혜;여신일;박광범;최석규;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제37권sup2호
    • /
    • pp.427-445
    • /
    • 2007
  • 임플란트와 골 사이의 결합력을 증가시키기 위하여 타이타늄 표면에 변화를 주기위한 많은 연구들이 진행되고 있다. 타이타늄의 표면 구조나 미세 지지도의 변화가 임플란트에 대한 세포의 반응에 영향을 미치며, 골아 유사세포는 표면 조도가 높은 타이타늄 표면에 더 잘 부착하며, 세포외 기질의 합성과 광물화 결정이 더 잘 일어난다고 알려져 있다. 그러나 대부분의 연구들은 마이크로 단위의 미세 지지도에 대한 연구들이고 나노 단위의 미세 지지도에 대한 연구들은 미미하다. 이에 본 연구에서는 ROS 17/2.8 cell line을 이용하여 기계적 처리만한 군을 대조군으로 하여 blasting 처리한 마이크로 단위의 미세 지지도 표면과 알칼리 처리된 나노 단위의 미세 지지도 표면에 대한 골아 유사세포의 세포 부착양상, 증식 그리고 골아 유사세포의 표식인자 발현양상 등을 상호 비교하여 골아 유사세포에 미치는 영향을 관찰하고자 하였다. SEM을 이용한 미세 지지도 관찰에서 알칼리 처리군에서는 약 200mm의 초미세 다공성의 양상을 나타내었고, blasting 처리한 군에서는 $10\;{\mu}m$ 이하의 움푹 파인 양상을 보였다. 표면조도 측정에 있어서는 blasting 처리한 군에서 기계적 처리와 알칼리 처리된 군보다 더 높은 표면 조도를 보였으며 이는 통계학적으로 유의한 차이를 나타내었다 (p<0.01). 표면결정성 분석에서는 알칼리처리 군에서 anatase와 rutile결정형이 보였으나, blasting 처리한 군과 기계적 처리 군에서는 관찰되지 않았다. 골아 유사세포 1시간 배양 후의 전자현미경 관찰에서 모든 군의 세포는 부착 및 전개 과정을 보였고, 3시간 배양에서는 모든 군의 세포가 더 많이 전개되었으나, blasting 처리한 군과 알칼리처리 군에서 세포가 다소 더 불규칙한 형태를 나타내었다. 24시간 배양에서는 모든 군의 세포에서 완전히 전개가 일어난 양상을 보였다. 1, 4, 7일간 세포배양 후 세포활성을 평가하기 위한 MTT assay에서는 모든 군에서 시간이 증가함에 따라 세포수가 증가하였으며, 1일째에 blasting 처리한 군과 알칼리처리 군에서 기계적 처리 군에 비해 세포활성도가 통계학적으로 유의한 증가를 보였다(p<0.01). 골아 유사세포 표식인자인 osteopontin, alkaline phosphatase, ${\alpha}\;1(1)$ collagen의 유전자 발현양상을 관찰해 본 결과, osteopontin, alkaline phosphatase, ${\alpha}\;1(1)$ collagen의 유전자 발현양상이 세 군 모두에서 유의한 차이는 관찰할 수 없었으나, blasting 처리한 군과 알칼리처리 군에서 기계적 처리 군에 비해 유전자 발현양상이 다소 증가하는 경향을 보였다. 결론적으로 blasting 처리한 마이크로 단위의 미세 지지도 표면과 알칼리 처리된 나노 단위의 미세 지지도 표면이 기계적 처리 군에 비해 골아 유사세포의 기능을 촉진시키나, 알칼리 처리된 나노 단위의 미세 지지도 표면은 blasting 처리한 마이크로 단위의 미세 지지도 표면이 골아 유사세포의 기능에 미치는 영향을 압도하지는 않는 것으로 사료된다.

인터넷 쇼핑몰 수용에 있어 사용자 능력의 조절효과 분석 (An Analysis of the Moderating Effects of User Ability on the Acceptance of an Internet Shopping Mall)

  • 서건수
    • Asia pacific journal of information systems
    • /
    • 제18권4호
    • /
    • pp.27-55
    • /
    • 2008
  • Due to the increasing and intensifying competition in the Internet shopping market, it has been recognized as very important to develop an effective policy and strategy for acquiring loyal customers. For this reason, web site designers need to know if a new Internet shopping mall(ISM) will be accepted. Researchers have been working on identifying factors for explaining and predicting user acceptance of an ISM. Some studies, however, revealed inconsistent findings on the antecedents of user acceptance of a website. Lack of consideration for individual differences in user ability is believed to be one of the key reasons for the mixed findings. The elaboration likelihood model (ELM) and several studies have suggested that individual differences in ability plays an moderating role on the relationship between the antecedents and user acceptance. Despite the critical role of user ability, little research has examined the role of user ability in the Internet shopping mall context. The purpose of this study is to develop a user acceptance model that consider the moderating role of user ability in the context of Internet shopping. This study was initiated to see the ability of the technology acceptance model(TAM) to explain the acceptance of a specific ISM. According to TAM. which is one of the most influential models for explaining user acceptance of IT, an intention to use IT is determined by usefulness and ease of use. Given that interaction between user and website takes place through web interface, the decisions to accept and continue using an ISM depend on these beliefs. However, TAM neglects to consider the fact that many users would not stick to an ISM until they trust it although they may think it useful and easy to use. The importance of trust for user acceptance of ISM has been raised by the relational views. The relational view emphasizes the trust-building process between the user and ISM, and user's trust on the website is a major determinant of user acceptance. The proposed model extends and integrates the TAM and relational views on user acceptance of ISM by incorporating usefulness, ease of use, and trust. User acceptance is defined as a user's intention to reuse a specific ISM. And user ability is introduced into the model as moderating variable. Here, the user ability is defined as a degree of experiences, knowledge and skills regarding Internet shopping sites. The research model proposes that the ease of use, usefulness and trust of ISM are key determinants of user acceptance. In addition, this paper hypothesizes that the effects of the antecedents(i.e., ease of use, usefulness, and trust) on user acceptance may differ among users. In particular, this paper proposes a moderating effect of a user's ability on the relationship between antecedents with user's intention to reuse. The research model with eleven hypotheses was derived and tested through a survey that involved 470 university students. For each research variable, this paper used measurement items recognized for reliability and widely used in previous research. We slightly modified some items proper to the research context. The reliability and validity of the research variables were tested using the Crobnach's alpha and internal consistency reliability (ICR) values, standard factor loadings of the confirmative factor analysis, and average variance extracted (AVE) values. A LISREL method was used to test the suitability of the research model and its relating six hypotheses. Key findings of the results are summarized in the following. First, TAM's two constructs, ease of use and usefulness directly affect user acceptance. In addition, ease of use indirectly influences user acceptance by affecting trust. This implies that users tend to trust a shopping site and visit repeatedly when they perceive a specific ISM easy to use. Accordingly, designing a shopping site that allows users to navigate with heuristic and minimal clicks for finding information and products within the site is important for improving the site's trust and acceptance. Usefulness, however, was not found to influence trust. Second, among the three belief constructs(ease of use, usefulness, and trust), trust was empirically supported as the most important determinants of user acceptance. This implies that users require trustworthiness from an Internet shopping site to be repeat visitors of an ISM. Providing a sense of safety and eliminating the anxiety of online shoppers in relation to privacy, security, delivery, and product returns are critically important conditions for acquiring repeat visitors. Hence, in addition to usefulness and ease of use as in TAM, trust should be a fundamental determinants of user acceptance in the context of internet shopping. Third, the user's ability on using an Internet shopping site played a moderating role. For users with low ability, ease of use was found to be a more important factors in deciding to reuse the shopping mall, whereas usefulness and trust had more effects on users with high ability. Applying the EML theory to these findings, we can suggest that experienced and knowledgeable ISM users tend to elaborate on such usefulness aspects as efficient and effective shopping performance and trust factors as ability, benevolence, integrity, and predictability of a shopping site before they become repeat visitors of the site. In contrast, novice users tend to rely on the low elaborating features, such as the perceived ease of use. The existence of moderating effects suggests the fact that different individuals evaluate an ISM from different perspectives. The expert users are more interested in the outcome of the visit(usefulness) and trustworthiness(trust) than those novice visitors. The latter evaluate the ISM in a more superficial manner focusing on the novelty of the site and on other instrumental beliefs(ease of use). This is consistent with the insights proposed by the Heuristic-Systematic model. According to the Heuristic-Systematic model. a users act on the principle of minimum effort. Thus, the user considers an ISM heuristically, focusing on those aspects that are easy to process and evaluate(ease of use). When the user has sufficient experience and skills, the user will change to systematic processing, where they will evaluate more complex aspects of the site(its usefulness and trustworthiness). This implies that an ISM has to provide a minimum level of ease of use to make it possible for a user to evaluate its usefulness and trustworthiness. Ease of use is a necessary but not sufficient condition for the acceptance and use of an ISM. Overall, the empirical results generally support the proposed model and identify the moderating effect of the effects of user ability. More detailed interpretations and implications of the findings are discussed. The limitations of this study are also discussed to provide directions for future research.

토픽 모델링을 이용한 트위터 이슈 트래킹 시스템 (Twitter Issue Tracking System by Topic Modeling Techniques)

  • 배정환;한남기;송민
    • 지능정보연구
    • /
    • 제20권2호
    • /
    • pp.109-122
    • /
    • 2014
  • 현재 우리는 소셜 네트워크 서비스(Social Network Service, 이하 SNS) 상에서 수많은 데이터를 만들어 내고 있다. 특히, 모바일 기기와 SNS의 결합은 과거와는 비교할 수 없는 대량의 데이터를 생성하면서 사회적으로도 큰 영향을 미치고 있다. 이렇게 방대한 SNS 데이터 안에서 사람들이 많이 이야기하는 이슈를 찾아낼 수 있다면 이 정보는 사회 전반에 걸쳐 새로운 가치 창출을 위한 중요한 원천으로 활용될 수 있다. 본 연구는 이러한 SNS 빅데이터 분석에 대한 요구에 부응하기 위해, 트위터 데이터를 활용하여 트위터 상에서 어떤 이슈가 있었는지 추출하고 이를 웹 상에서 시각화 하는 트위터이슈 트래킹 시스템 TITS(Twitter Issue Tracking System)를 설계하고 구축 하였다. TITS는 1) 일별 순위에 따른 토픽 키워드 집합 제공 2) 토픽의 한달 간 일별 시계열 그래프 시각화 3) 토픽으로서의 중요도를 점수와 빈도수에 따라 Treemap으로 제공 4) 키워드 검색을 통한 키워드의 한달 간 일별 시계열 그래프 시각화의 기능을 갖는다. 본 연구는 SNS 상에서 실시간으로 발생하는 빅데이터를 Open Source인 Hadoop과 MongoDB를 활용하여 분석하였고, 이는 빅데이터의 실시간 처리가 점점 중요해지고 있는 현재 매우 주요한 방법론을 제시한다. 둘째, 문헌정보학 분야뿐만 아니라 다양한 연구 영역에서 사용하고 있는 토픽 모델링 기법을 실제 트위터 데이터에 적용하여 스토리텔링과 시계열 분석 측면에서 유용성을 확인할 수 있었다. 셋째, 연구 실험을 바탕으로 시각화와 웹 시스템 구축을 통해 실제 사용 가능한 시스템으로 구현하였다. 이를 통해 소셜미디어에서 생성되는 사회적 트렌드를 마이닝하여 데이터 분석을 통한 의미 있는 정보를 제공하는 실제적인 방법을 제시할 수 있었다는 점에서 주요한 의의를 갖는다. 본 연구는 JSON(JavaScript Object Notation) 파일 포맷의 1억 5천만개 가량의 2013년 3월 한국어 트위터 데이터를 실험 대상으로 한다.

산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도 (The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching)

  • 김유리;김지환;심준성;김광만;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.148-156
    • /
    • 2008
  • 자가부식 접착제는 사용하기 쉽고, 술식 민감성이 적은 장점이 있으나 특히 산도가 약한 자가부식 접착제의 법랑질에 대한 결합력은 논란이 되고 있다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond (Kuraray, Okayama, Japan)의 연마 법랑질에 대한 미세인장 결합강도를 측정하여 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) 및 1단계 자가부식 접착제인 iBond (Heraeus Kulzer Gmbh, Hanau, Germany)의 결합강도와 비교하고자 하였고, 2단계 자가부식 접착제에 산부식 전처리를 시행하는 것이 법랑질에 대한 결합강도를 높일 수 있는지 알아 보고자 하였다. 실험군은 2단계 자가부식 접착제인 Clearfil SE Bond만 사용한 비산부식 군과 35% 인산 (Scotchbond Etchant, 3M ESPE)으로 산부식 후 Clearfil SE Bond를 사용한 산부식 군, 그리고 1단계 자가부식 접착제인 iBond를 사용한 군으로 나누었다. 대조군은 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose를 사용한 군으로 정하였다. Bovine 전치의 순면을 십자가형으로 4등분하여 각 군으로 무작위로 배분하였다. 각 치아의 순면을 800-grit 실리콘 카바이드 지로 연마한 후 삭제된 법랑질면에 제조사의 설명서에 따라 각 군의 접착제를 적용하고 Light-Core (Bisco)로 적층 충전하였다. 시편은 $37i{\acute{E}}$, 증류수에 일주일 동안 보관한 후 low speed precicion diamond saw (TOPMENT Metsaw-LS, R&B, Daejeon, Korea)를 이용하여 약 $0.8{\times}0.8mm$ 단면이 되도록 시편을 절단하여 미세시편을 제작하였다. 일주일마다 증류수를 교환하면서 한 달, 세 달 동안 $37i{\acute{E}}$, 증류수에 미세시 편을 보관한 후 각각의 미세인장결합강도를 측정하였다. 미세인장결합강도 (MPa)는 파절 시에 가해진 힘 (N)을 접착면적 ($mm^2$)으로 나누어 계산하였다. 접착계면에서의 파절 양상은 실물현미경 (Microscope-B nocular, Nikon)을 이용하여 분류하였다. 미세인장결합강도에 대한 통계분석은 one-way ANOVA를 이용하여 유의수준 5%에서 검정하였고, 사후감정은 Least Significant Difference 방법을 이용하였다. 중합 후 1개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 모든 접착제 간에 유의한 차이가 없었다. 3개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 iBond 와 Clearfil SE Bond 비산부식 군과 Scotchbond Multi- Purpose 간에는 각각 유의한 차이가 없었다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond의 연마 법랑질에 대한 미세인장결합강도가 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose 와 비교하여 유의한 차이가 없었으며 (P>0.05), 3개월 후의 결과에서 Clearfil SE Bond 비산부식 군의 미세인장결합강도가 Clearfil SE Bond 산부식 군보다 유의하게 낮았다 (P<0.05). 즉 35% 인산으로 산부식 전처리를 시행한결과 Clearfil SE Bond 의 법랑질에 대한 결합강도가 증가하였다.

스마트교육을 위한 오픈 디지털교과서 (Open Digital Textbook for Smart Education)

  • 구영일;박충식
    • 지능정보연구
    • /
    • 제19권2호
    • /
    • pp.177-189
    • /
    • 2013
  • 스마트교육에서 디지털교과서의 역할은 학습자와 대면하는 교육미디어로써 그 중요성은 재론의 여지없다. 이러한 디지털교과서는 학습자의 편의와 더불어 교수자, 콘텐츠 제작자, 유통업자를 위하여 표준화되어야 활성화되고 산업화될 수 있다. 본 연구에서는 다음과 같은 3가지 목표를 지향하는 디지털교과서 표준화 방안을 모색한다. (1) 디지털교과서는 온-오프 수업을 모두 지원하는 혼합학습 매체의 역할을 해야 하며, 특별한 전용뷰어 없이 표준을 준수하는 모든 EPUB 뷰어에서 실행가능 해야 하며, 기존의 이러닝 학습 콘텐츠와 학습관리시스템를 활용할 수 있도록 하며, 디지털 교과서를 사용하는 학습자의 정보를 추적 관리할 수 있는 트랙킹기능이 있으면서도, 오프라인 동안의 정보를 축적하여 서버와 통신할 수 있는 기능도 필요하다. 디지털교과서의 표준으로서 EPUB을 고려하는 이유는 디지털교과서가 책의 형태를 가져야 하는데 이를 위해서 따로 표준을 정할 필요가 없으며, EPUB 표준을 채택함으로써 풍부한 콘텐츠, 유통구조, 산업기반을 활용할 수 있기 때문이다. (2) 디지털교과서는 오픈소스를 적극 활용하여 저비용으로 현재 사용가능한 서비스를 구성하여 표준과 더불어 실제 실행 가능한 프로그램으로 제시되어야 하며, 관련 학습 콘텐츠가 오픈마켓의 형태로 운영될 수 있어야 한다. (3) 디지털교과서는 학습자에게 적절한 학습 피드백을 제공하기 위하여 모든 학습활동 정보를 축적하고 관리될 수 있는 인프라를 표준에 따라 구축하여 교육 빅데이터 처리의 기반을 제공하여야 한다. 이북 표준인 EPUB 3.0을 기반으로 하는 오픈 디지털교과서는 (1) 학습활동 정보를 기록하고 (2) 이 학습활동 지원을 위한 서버와 통신하여야 한다. 현재 표준으로 정해져 있지 않은 이북의 기록과 통신 기능을 EPUB 3.0의 JavaScript로 구현하여 현재 EPUB 3.0 뷰어에서도 활용하면서 이를 차세대 이북 표준 또는 교육을 위한 이북 표준(EPUB 3.0 for education)으로 제안하여 향후 제정된 표준 이북 뷰어에서는 JavaScript없이도 처리되도록 하는 전략이 필요하다. 향후 연구는 제안한 오픈 디지털교과서 표준에 의한 오픈소스 프로그램을 개발하고, 개발된 오픈 디지털교과서의 학습활동정보를 활용한 새로운 교육서비스 방안(교육 빅데이터 활용방안 포함)을 제시하는 것이다.

고객 맞춤형 서비스를 위한 관객 행동 기반 감정예측모형 (The Audience Behavior-based Emotion Prediction Model for Personalized Service)

  • 유은정;안현철;김재경
    • 지능정보연구
    • /
    • 제19권2호
    • /
    • pp.73-85
    • /
    • 2013
  • 정보기술의 비약적 발전에 힘입어, 오늘날 기업들은 지금까지 축적한 고객 데이터를 기반으로 맞춤형 서비스를 제공하는 것에 많은 관심을 가지고 있다. 고객에게 소구하는 맞춤형 서비스를 효과적으로 제공하기 위해서는 우선 그 고객이 처한 상태나 상황을 정확하게 인지하는 것이 중요하다. 특히, 고객에게 서비스가 전달되는 이른바 진실의 순간에 해당 고객의 감정 상태를 정확히 인지할 수 있다면, 기업은 더 양질의 맞춤형 서비스를 제공할 수 있을 것이다. 이와 관련하여 사람의 얼굴과 행동을 이용하여 사람의 감정을 판단하고 개인화 서비스를 제공하기 위한 연구가 활발하게 이루어지고 있다. 얼굴 표정을 통해 사람의 감정을 판단하는 연구는 좀 더 미세하고 확실한 변화를 통해 정확하게 감정을 판단할 수 있지만, 장비와 환경의 제약으로 실제 환경에서 다수의 관객을 대상으로 사용하기에는 다소 어려움이 있다. 이에 본 연구에서는 Plutchik의 감정 분류 체계를 기반으로 사람들의 행동을 통해 감정을 추론해내는 모형을 개발하는 것을 목표로 한다. 본 연구는 콘텐츠에 의해 유발된 사람들의 감정적인 변화를 사람들의 행동 변화를 통해 판단하고 예측하는 모형을 개발하고, 4가지 감정 별 행동 특징을 추출하여 각 감정에 따라 최적화된 예측 모형을 구축하는 것을 목표로 한다. 모형 구축을 위해 사람들에게 적절한 감정 자극영상을 제공하고 그 신체 반응을 수집하였으며, 사람들의 신체 영역을 나누었다. 특히, 모션캡쳐 분야에서 널리 쓰이는 차영상 기법을 적용하여 사람들의 제스쳐를 추출 및 보정하였다. 이후 전처리 과정을 통해 데이터의 타임프레임 셋을 20, 30, 40 프레임의 3가지로 설정하고, 데이터를 학습용, 테스트용, 검증용으로 구분하여 인공신경망 모형을 통해 학습시키고 성과를 평가하였다. 다수의 일반인들을 대상으로 수집된 데이터를 이용하여 제안 모형을 구축하고 평가한 결과, 프레임셋에 따라 예측 성과가 변화함을 알 수 있었다. 감정 별 최적 예측 성과를 보이는 프레임을 확인할 수 있었는데, 이는 감정에 따라 감정의 표출 시간이 다르기 때문인 것으로 판단된다. 이는 행동에 기반한 제안된 감정예측모형이 감정에 따라 효과적으로 감정을 예측할 수 있으며, 실제 서비스 환경에서 사용할 수 있는 효과적인 알고리즘이 될 수 있을 것으로 기대할 수 있다.