• Title/Summary/Keyword: IFA.

Search Result 204, Processing Time 0.02 seconds

IPI feeding structure for the gain improvement of IFA (IFA 이득 향상을 위한 IPI 급전 구조)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.817-823
    • /
    • 2010
  • Design of IPI feeding structure affecting the antenna gain improvement of mobile phone was investigated. IPI feeder which based on the T matching theory increase line current for internal antenna such as IFA. So IPI feeder makes higher radiation resistance, and also increases the gain with increasing radiation efficiency. To verify IPI feeding effect, feeder is applied to conventional CDMA/DCS dual band IFA. Measurement shows that IPI-IFA has 0.5 ~ 1.4[dBi] higher gain than conventional IFA at CDMA/DCS band. Resonant frequency did not change.

Design of the IPI-IFA using the Inverted PI Feeder (역 파이 급전 방식을 적용한 IPI-IFA)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.5
    • /
    • pp.662-668
    • /
    • 2009
  • Design of IPI(Inverted PI) feeding internal antenna for the gain improvement of mobile phone was proposed. IPI feeding structure affects on both low radiation resistance of antenna and increase current for the internal antenna such as IFA(Inverted F Antenna). By these facts, antenna fed by IPI can get the gain improvement with increasing radiation efficiency. For the verification, we applied IPI feeding structure to conventional quad band IFA. Measurement shows that IPI-IFA has 0.3~2.0[dB] higher gain than conventional IFA on GSM/DCS/USPCS/WCDMA band.

  • PDF

Evaluation for detection of Cryptosporidium oocysts in diarrheal feces of calves (야외 송아지 설사변에서 작은와포자충 검출에 대한 평가)

  • Wi, Seong-Hwan;Ju, Hu-Don;Gang, Yeong-Bae
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.2
    • /
    • pp.121-126
    • /
    • 1996
  • For the detection of Cwptospori,mum oocysts, fecal samples were collected from 201 calves which showed diarrhea. Among the 201 samples, 29 samples (14.4%) were positive for Cwptosporinium spry. by the DMSO-modified acid-fast stain (MAFS) , 23 samples (11.4%) were positive by commercial kit (Meridian Diagnostics, Cincinnati, Ohiol and 23 by the indirect immunofluorescence antibody (IFA )assay employing the monoclonal antibody (mAb C6). When tested by both IFA and MAFS, 20 fecal samples were positive for Cwptosporinium oocysts whereas 169 fecal samples were negative. If the MAFS is considered a standard method for oocyst detection, the IFA showed 69% of sensitivity and 98% of specificity. When tested by both IFA and commercial kit, 22 fecal samples were positive for Cwptospori,mum oocysts while 177 samples were negative. One sample tested by IFA was found to be false negative, when compared with the results by commercial kit. The sensitivity of IFA was calculated as high as 96%; the specificity as 99% and the predictive value was also 99%. In the present study, IFA employing the nAb C6 revealed that 23 samples (11.4%) were positive among the 201 calves showing diarrhea. Of 23 IFA positive samples, 4 samples (5%) showed cryptosporidial oocysts more than 105 OPG Therefore. it is concluded that the calves showing cryptosporidial oocysts more than 105 OPG in the feces were highly associated with clinical cryptosporidiosis.

  • PDF

Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test (Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단)

  • Lee, Byung-hoon;Lee, Eung-goo;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF

A Study on the Design and Implementation of SHF band IFA for Digital Satellite Communication (디지털위성중계기용 SHF대역 입력필터 조립체의 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.545-548
    • /
    • 2017
  • This study describes the design and implementation of IFA(Input Filter Assembly) for Digital Satellite Communication. The IFA unit for SHF band consists of coupler, LPF(Low Pass Filter) and input Filter. Through the pre-simulation analysis of space environment, the possibility of the malfunction of equipment minimized and we designed a reliable IFA through simulation for vibration analysis generated during the launch, and compared pre-simulation of main performance results to test results about main performances of IFA after production.

PIFA and IFA Hybrid Antenna for the Data Communication Terminal (데이터통신 단말기용 PIFA 및 IFA 결합 안테나)

  • Chun, Moon-Kyu;Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.65-70
    • /
    • 2011
  • In this paper, we designed and implemented a PIFA(Planer Inverted F Antenna) and IFA(Inverted F Antenna) hybrid antenna for the data communication terminal such as smart phone. Studied hybrid antenna has multi-band characteristics by the simultaneous operation both PIFA and IFA under a feeding structure. VSWR measurement of implemented antenna was satisfied 3:1 over GSM900/USPCS/WCDMA band. Measured average gains and efficiencies were -2.19~-3.63 dBi and 43.31~60.33 % for the GSM900 band, and -2.16~-10.67 dBi and 8.56~60.78 % for the USPCS/WCDMA band.

Design Technique Using Bypass Capacitor to Improve Antenna Efficiency of Inverted-F Antenna with Band Stop Matching Circuit (Band Stop Matching Circuit이 적용된 Inverted-F Antenna의 Bypass Capacitor를 이용한 안테나 효율 향상 기법)

  • Bae, Jang Hwan;Choi, Woo Cheol;Lim, Seonho;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • In this paper, a design technique using a bypass capacitor is proposed to improve the antenna efficiency of an inverted-F antenna (IFA) with a band stop matching circuit (BSMC). The proposed antenna operates in the LTE bands 26 and 5(814~ 894 MHz). The bandwidth of the IFA is expanded from 803~863 MHz to 800~888 MHz using the impedance change caused by the BSMC. To enhance the antenna efficiency in the expanded frequency band, the bypass capacitor is applied to the IFA with the BSMC. The bypass capacitor improves the efficiency of the antenna by reducing the current variation of the IFA with the BSMC. The proposed antenna has a bandwidth of 804~895 MHz and the antenna efficiency increases by more than 10 % in the extended frequency band by using the bypass capacitor.

Potential clinical utility of intraoperative fluid amylase measurement during pancreaticoduodenectomy

  • Kunal Joshi;Manuel Abradelo;David Christopher Bartlett;Nikolaos Chatzizacharias;Bobby Venkata Dasari;John Isaac;Ravi Marudanayagam;Darius Mirza;Keith Roberts;Robert Peter Sutcliffe
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.2
    • /
    • pp.189-194
    • /
    • 2023
  • Backgrounds/Aims: Postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD) is a source of major morbidity and mortality. Early diagnosis and treatment of POPF is mandatory to improve patient outcomes and clinical risk scores may be ombined with postoperative drain fluid amylase (DFA) values to stratify patients. The aim of this pilot study was to etermine if intraoperative fluid amylase (IFA) values correlate with DFA1 and POPF. Methods: In patients undergoing PD from February to November 2020, intraoperative samples of intra-abdominal fluid adjacent to the pancreatic anastomosis were taken and sent for fluid amylase measurement prior to abdominal closure. Data regarding patient demographics, postoperative DFA values, complications, and mortality were prospectively collected. Results: Data were obtained for 52 patients with a median alternative Fistula Risk Score (aFRS) of 9.9. Postoperative complications occurred in 20 (38.5%) patients (five Clavien grade ≥ 3). There were eight POPFs and two patients died (pneumonia/sepsis). There was a significant correlation between IFA and DFA1 (R2 = 0.713; p < 0.001) and DFA3 (p < 0.001), and the median IFA was higher in patients with POPF than patients without (1,232.5 vs. 122; p = 0.0003). IFA > 260 U/L predicted POPF with sensitivity, specificity, positive and negative predictive values of 88.0%, 75.0%, 39.0%, and 97.0%, respectively. The incidence of POPF was 43.0% in high-risk (high aFRS/IFA) and 0% in lowrisk patients (low aFRS/IFA). Conclusions: IFA correlated with POPF and may be a useful adjunct to clinical risk scores to stratify patients during PD. Larger, prospective studies are needed to determine whether IFA has clinical utility.

Comparison between indirect immunofluorescent antibody (IFA) test and enzyme-linked immunosorbent assay (ELISA) for the detection of antibody to porcine reproductive and respiratory syndrome virus(PRRSV) (돼지 생식기호흡기증후군 바이러스항체 검색에 있어 간접형광항체법(IFA) 과 효소면역법(ELISA)의 진단효율 비교)

  • Park, Choi-kyu;Lyoo, Young-soo;Lee, Chang-hee;Jung, Jong-wook
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.314-318
    • /
    • 1998
  • An establishment of effective control measures to PRRSV infection in swine industry depends on a sensitive and specific diagnosis to detect either viral antigen and/or antibodies to PRRSV. Several diagnostic methods are available to detect antibodies against PRRSV, including IPMA, IFA and ELISA tests have been successfully developed. Sensitivity of the indirect immunofluorescent assay in MA-104 cells using Korean field isolate PL96-1 was superior to that of VR-2332 and field isolate PL96-2. Sensitivity and specificity of the IFA test with PL96-1 were comparable to those of commercial ELISA test kit but ELISA test was more sensitive for the detection of declining antibodies to PRRSV in finishing pigs. In this study we concluded that IFA and ELISA test could be utilized to detect antibodies to PRRSV and the results generated from these two tests were comparable and there were no significant difference between these two tests.

  • PDF

Implementation of Miniaturized 433MHz Antenna Using IFA Structure (IFA 구조를 이용한 소형 433MHz 안테나의 구현)

  • Kang, Sang-Won;Chang, Tae-Soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.203-208
    • /
    • 2014
  • In this paper, the antenna of a small active RFID for 433MHz is proposed, and the proposed antenna is a kind of built-in antenna, which uses IFA structure. The performance was improved by the change of the spacing between the feed point and short strip, inserting the meander line structure in a radiator, and varying the gap between the radiator and the ground plane in the proposed antenna. To confirm the characteristics of the antenna parameters, HFSS from ANSYS Inc. was used for the analysis. The frequency band of 433MHz Active RFID is from 433.67 to 434.17 MHz. There is a value of return loss less than -9.54 dB in 433MHz band of the active RFID, and the maximum antenna gain is -4.28dBi. The Jig size of the proposed antenna is $72{\times}44{\times}1mm$, and the size of the antenna area is $35.5{\times}19.5mm$. The result proved the possibility of the practical use on miniaturized 433MHz antenna using IFA structure that came from comparing and analyzing the measured and simulated data of the antenna.