Dose metrology: TLD/OSL dose accuracy and energy response performance

  • Omaima Essaad Belhaj;Hamid Boukhal;El Mahjoub Chakir;Meryeme Bellahsaouia;Siham Belhaj;Younes Sadeq;Mohammed Tazi;Tahar El Khoukhi;Maryam Hadouachi;Khaoula Laazouzi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.717-724
    • /
    • 2023
  • An essential step in evaluating and comparing the performance of two passive radiation dosimeter types, thermosluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments with ionizing radiation for individual radiological monitoring and control of external exposure at various times (cumulative dose for 1 month), is to compare the measured dose accuracy, energy response, and coefficient of variation. In fact this performance study consists in determining the accuracy of both R(10) and R(0.07) which are considered as the ratios of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy. The validity of the results of this test is based on the acceptance limits of the ICRP and the international standard IEC-62387. The relative energy response used is normalized to the 137Cs 662 keV energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine the statistical fluctuation of the Hp(10) and Hp(0.07) doses. The results of the accuracy test for the OSL and TLD dosimeters are acceptable because they fall within the ICRP limits. For the energy response, the OSL performs better than the TLD for Hp(10) and Hp(0.07), and for the coefficient of variation, the OSL satisfies the requirements of ISO 62387 for both Hp(10) and Hp(0.07), while the TLD satisfies these requirements only for the measurement of Hp (0.07).

Current Status of International Standardization for Durability Test Methods in Smart Clothing and Future Challenges in Enhancing Product Reliability and Quality Control (스마트 의류의 사용환경 내구성 시험에 대한 국제 표준화 현황과 제품의 신뢰성 향상 및 품질 관리를 위한 향후 과제)

  • Siyeon Kim;Ga-Young Lim;Sukyung Kim;Junghyun Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.3
    • /
    • pp.398-408
    • /
    • 2023
  • Smart clothing products can experience a decrease in performance and reliability due to various mechanical, biological, and chemical stress factors that occur throughout their life cycle. These issues can hinder consumer acceptance of the products. This study aims to enhance the reliability of smart clothing and facilitate quality control by analyzing and identifying the current status of international standardization for smart clothing and electronic textiles (e-textiles). The focus of this analysis was on the durability test methods in the use environment. Furthermore, similar standards published by different standardization organizations for durability tests were compared in depth. The study showed that a total of 27 international standards have been developed or are currently under development. The current standardization efforts mainly aim to develop functionality and durability test methods for smart clothing and e-textile products. A detailed comparison was made between two international standards (IEC 63023-204-1:2023 and AATCC TM210:2019) specifically in relation to the washing durability test method and the electrical resistance measurement standards (BS EN 16812:2016 vs AATCC EP13-2021), before and after the environmental exposure tests. Based on this comparison, several suggestions have been made and discussed for the future revision of these international standards.

A Study on the Safety of Carbon Manufacturing By-product Gas Emissions (카본제조 부생가스 배출 안전성에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Kim, Sang-Gil;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

A Design and Implementation of Multimedia Retrieval System based on MAF(Multimedia Application File Format) (MAF(Multimedia Application File Format) 기반 멀티미디어 검색 시스템의 설계 및 구현)

  • Gang Young-Mo;Park Joo-Hyoun;Bang Hyung-Gin;Nang Jong-Ho;Kim Hyung-Chul
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.574-584
    • /
    • 2006
  • Recently, ISO/IEC 23000 (also known as 'MPEG-A') has proposed a new file format called 'MAF(Multimedia Application File Format)[1]' which provides a capability of integrating/storing the widely-used compression standards for audio and video and the metadata in MPEG-7 form into a single file format. However, it is still very hard to verify the usefulness of MPEG-A in the real applications because there is still no real system that fully implements this standard. In this thesis, a design and implementation of a multimedia retrieval system based on MPEG-A standard on PC and mobile device is presented. Furthermore, an extension of MPEG-A for describing the metadata for video is also proposed. It is selected and defined as a subset of MPEG-7 MDS[4] and TV-anytime[5] for video that is useful and manageable in the mobile environments. In order to design the multimedia retrieval system based on MPEG-A, we define the system requirements in terms of portability, extensibility, compatibility, adaptability, efficiency. Based on these requirements, we design the system which composed of 3 layers: Application Layer, Middleware Layer, Platform Layer. The proposed system consists of two sub-parts, client-part and server-part. The client-part consists of MAF authoring tool, MAP player tool and MAF searching tool which allow users to create, play and search the MAF files, respectively. The server-part is composed of modules to store and manage the MAF files and metadata extracted from MAF files. We show the usefulness of the proposed system by implementing the client system both on MS-Windows platform on desk-top computer and WIPI platform on mobile phone, and validate whether it to satisfy all the system requirements. The proposed system can be used to verify the specification in the MPEG-A, and to proves the usefulness of MPEG-A in the real application.

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Derivation of Nacelle Transfer Function Using LiDAR Measurement (라이다(LiDAR) 측정을 이용한 나셀전달함수의 유도)

  • Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.929-936
    • /
    • 2015
  • Nacelle anemometers are mounted on wind-turbine nacelles behind blade roots to measure the free-stream wind speed projected onto the wind turbine for control purposes. However, nacelle anemometers measure the transformed wind speed that is due to the wake effect caused by the blades' rotation and the nacelle geometry, etc. In this paper, we derive the Nacelle Transfer Function (NTF) to calibrate the nacelle wind speed to the free-stream wind speed, as required to carry out the performance test of wind turbines according to the IEC 61400-12-2 Wind-Turbine Standard. For the reference free-stream wind data, we use the Light Detection And Ranging (LiDAR) measurement at the Shinan wind power plant located on the Bigeumdo Island shoreline. To improve the simple linear regression NTF, we derive the multiple nonlinear regression NTF. The standard error of the wind speed was found to have decreased by a factor of 9.4, whereas the mean of the power-output residual distribution decreased by 6.5 when the 2-parameter NTF was used instead of the 1-parameter NTF.

A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System (전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구)

  • Cho Jin-Young;Mun Jun-Chul;Jung Chang-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.622-631
    • /
    • 2005
  • In this paper, we reduce 'over and under deviation' and 'over and under testing' which have a cause of uncertainty in electromagnetic radiated immunity test. We analyze continued measurement method of field uniformity and propose new estimate method having the minimum uncertainty condition. We test comparison in 4 anechoic chambers and analyze FDI(Field Deviation Index) which is the minimum deviation excess 6 dB on fields. We obtain that the proposed test method improve 1.193 dB than domestic standard(KN 61000-4-3) and 0.017 dB than international standard (IEC61000-4-3) in every frequency. In the test result 'over and under testing point' have 926 point at every field area and have 118 point at center uniform area. These result know that proposed measurement method have 10 point less at every field area and 9 point less at center uniform area than continued measurement method. The proposed test method have few point more than continued measurement method. Therefore, we confirmed that the proposed test method have the minimum uncertainty in electromagnetic radiated immunity test.