• Title/Summary/Keyword: IEC Standard

Search Result 849, Processing Time 0.032 seconds

Research on The System Software Quality Certification Implementation Plan of DQ Mark Certification (DQ마크 인증제도의 시스템 소프트웨어 품질인증 수행 방안 연구)

  • Yun, Jae-Hyeong;Song, Chi-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.85-91
    • /
    • 2021
  • The DAPA (Defense Acquisition Program Administration) has been operating the DQ mark certification since 2012 to certify the superior technology and quality of munitions. On the other hand, the current DQ mark certification can not directly provide DQ mark certification to software because it is impossible to verify the quality of software alone. Therefore, this study analyzed domestic/overseas software quality evaluation/certification standards to find a way to verify the quality of software in the DQ mark certification. Among them, the method of applying the GS certification according to the international standard ISO/IEC 25000 series to the DQ mark certification was suggested as an improvement plan, and DQ mark certification verified the quality of software and provided certification. An attempt was made to expand the certification scope of DQ mark certification. This paper proposes that the DQ mark can be given to the system software by introducing GS certification to the DQ mark certification. To this end, an improved procedure for omitting the factory audit and verification by submitting a GS certificate for product evaluation is proposed. This is expected to increase defense exports using the granted DQ mark and improve the quality of defense software products through GS certification.

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM (SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1139-1147
    • /
    • 2023
  • The purpose of this paper is to present and evaluate the performance of a method for controlling the dose for optimal image acquisition while minimizing patient exposure by applying a small-sized Photomultiplier(SiPM) sensor inside a portable detector. Portable detectors have the advantage of being able to quickly access the patient's location for rapid diagnosis, but this mobility comes with the challenge of dose control. This paper presents a method to identify the dose that can have the DQE and optimal image quality of the detector through image evaluation based on IEC62220-1-1, an international standard for X-ray imaging devices, and to identify the optimal dose by matching the ADU of the image and the output of the SiPM Sensor. The Skull AP image was acquired by implementing the detector manufacturer's reference dose. The optimal dose was 342.8 µGy, and the optimal controlled dose was 148.3 µGy, which is 57 % of the manufacturer's reference dose. The Chest AP image was 81.9 µGy and the optimal controlled dose was 27.9 µGy, which is a high dose reduction effect of 66 %. In addition, the two images were analyzed by five radiologists and found to have no clinically significant difference in anatomical delineation.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET (TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가)

  • Moon, Il-Sang;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2012
  • Purpose: To verify the optimal scan time per bed for clinical application, we evaluated the quality of $^{18}F$-FDG images with varying scan times in a phantom and 20 patients with 38 lesions using a Philips (TOF) PET/CT scanner. Materials and Methods: The PET/CT images of a NEMA IEC body phantom and 20 patients (16 males, 4 females) were acquired for 5 different scan times of 20-100 sec per bed with intervals of 20 sec. The activity ratio of hot spheres (diameter of 17 [H1], 22 [H2] and 28 [H3] mm) to the background region in the IEC body phantom was 8-to-1. The contrast recovery coefficient (CRC) and standard uptake value (SUV) based on ROIs of hot spheres and background region were calculated. The noise in each background region was estimated as the ratio of SD of counts to the mean counts in the background region. On the patient image, the injected dose of $^{18}F$-FDG was $444{\pm}74$ MBq and the SUVs in the 38 hot lesions were measured. Results: The two scan time groups (LT-60 [<60 sec] and GT-60 [${\geq}60$ sec]) were compared. In the phantom study, the coefficient of deviations (CVs, %) of CRC and SUV in LT-60 (H1: 14.2 and 7.3, H2: 11.4 and 7.8, H3: 4.9 and 3.2) were higher than GT-60 (H1: 8.9 and 2.8, H1: 8.2 and 5.0, H3: 2.0 and 1.6). In the patient study, the mean CV of CRC and SUV in LT-60 (4.0) was higher than GT-60 (1.2). Conclusion: This study showed that noise increased as the scan time decreased. High noise for the scan time <60 sec per bed yielded high variation of SUV and CRC. Therefore, considering PET/CT image quality, the scan time per bed in the TOF PET/CT scanner should be at least ${\geq}60$ sec.

  • PDF

Study on Fault Diagnosis Method of Train Communication Network applied to the prototype Korean High Speed Train

  • Cho, Chang-Hee;Park, Min-Kook;Kwon, Soon-Man;Kim, Yong-Ju;Kim, Sung-Shin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2169-2173
    • /
    • 2003
  • The development project of Korean High Speed Train (KHST) was started in 1996. As a national research project, the KHST project aims for a development of the next generation prototype train that has a maximum speed of 350 km/h. The development process of prototype KHST including 7 vehicles was completed last year and currently the prototype train is on its way of test running over the test track with gradually increased speed. The prototype KHST uses the real time network called TCN (Train Communication Network) for exchanging information between various onboard control equipments. After 10 years of development and modification period, TCN was confirmed as international standard (IEC61375-1) for the electrical railway equipment train bus. In the prototype KHST, all major control devices are connected by TCN and exchange their information. Such devices include SCU (Supervisory Control Unit), ATC (Automatic Train Control), TCU (Traction Control Unit), and so forth. For each device that sends and receives data using TCN, a device has to find out whether TCN is in normal or failure state before its data exchange. And also a device must have a proper method of data validation that was received in a normal TCN state. This is a one of the major important factors for devices using network. Some misleading information can lead the entire system to a catastrophic condition. This paper briefly explains how TCN was implemented in the prototype KHST train, and also shows what kind of the fault diagnosis method was adopted for a fail safe operation of TCN system

  • PDF

A Study on Application of Systems Engineering Approach to Design of Smart Manufacturing Execution System (스마트 제조 실행 시스템 기본설계를 위한 시스템 엔지니어링 적용 방법에 대한 연구)

  • Jeon, Byeong-woo;Shin, Kee-Young;Hong, Dae-Geun;Suh, Suk-Hwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.11 no.2
    • /
    • pp.95-105
    • /
    • 2015
  • Manufacturing Execution System(MES) is in charge of manufacturing execution in the shop floor based on the inputs given by high level information such as ERP, etc. The typical MES implemented is not tightly interconnected with shop floor control system including real (or near real) time monitoring and control devices such as PLC. The lack of real-time interfaces is one of the major obstacles to achieve accurate and optimization of the total performance index of the shop floor system. Smart factory system in the paradigm of Industry 4.0 tries to solve the problems via CPS (Cyber Physical System) technology and FILS (Factory In-the-Loop System). In this paper, we conducted Systems Engineering Approach to design an advanced MES (namely Smart MES) that can accommodate CPS and FILS concept. Specifically, we tailored Systems Engineering Process (SEP) based on an International Standard formalized as ISO/IEC 15288 to develop Stakeholders' Requirements (StR), System Requirements (SyR). The deliverables of each process are modeled and represented by the SysML, UML customized to Systems Engineering. The results of the research can provide a conceptual framework for future MES that can play a crucial role in the Smart Factory.

Video Data Compression using the MPEG-2 Video Algorithm (MPEG-2 비디오 알고리즘을 이용한 비디오 데이터 압축)

  • 남재열;이영선;이현주;김재곤;이상미;안치득
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.8
    • /
    • pp.1069-1082
    • /
    • 1993
  • The International Organization for Standardization(ISO) has undertaken an effort to develop a standard for video and associated audio on digital storage media. This effort is known by the name of the expert group that started if : MPEG-Moving Picture Experts Group Is currently part of the ISO-I EC/J TC1/SC2/WG11. The promise of MPEG-2 is that a video signal and its associated audio can be compressed to a bit rate of about 10 Mbits/s with an acceptable quality. In this paper, the implementation of a video compression simulator based on MPEG-2 Video Test Model 2(TM2) is described and analyzed according to the simulation results. The implemented simulator is also applied to code HDTV sequences at the several bit rates. Some computer simulation results using the MPEG and the HDTV test sequences are given. In addition, some techniques which can improve the coding efficiency of the implemented video compression simulator are also suggested.

  • PDF

Image Feature Point Selection Method Using Nearest Neighbor Distance Ratio Matching (최인접 거리 비율 정합을 이용한 영상 특징점 선택 방법)

  • Lee, Jun-Woo;Jeong, Jea-Hyup;Kang, Jong-Wook;Na, Sang-Il;Jeong, Dong-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.124-130
    • /
    • 2012
  • In this paper, we propose a feature point selection method for MPEG CDVS CE-7 which is processing on International Standard task. Among a large number of extracted feature points, more important feature points which is used in image matching should be selected for the compactness of image descriptor. The proposed method is that remove the feature point in the extraction phase which is filtered by nearest neighbor distance ratio matching in the matching phase. We can avoid the waste of the feature point and employ additional feature points by the proposed method. The experimental results show that our proposed method can obtain true positive rate improvement about 2.3% in pair-wise matching test compared with Test Model.