• Title/Summary/Keyword: IEC Rule

Search Result 27, Processing Time 0.037 seconds

Development of real-time embedded systems for reducing the transmission delay latency in IEC 61850 communication (IEC 61850 통신에서의 전송 지연시간 개선을 위한 실시간 임베디드 시스템 개발)

  • Cho, Chang-Doo;Kang, Seung-Hwa;Kang, Sang-Hee;Nam, Soon-Ryul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1590-1594
    • /
    • 2012
  • Depend on delay latency rule for message transmission defined in IEC 61850 standard, the fastest message has to be transferred within 3us. This paper suggests how to structure the real time message transmit test environment of IEC 61850 and develope how to securing IEC 61850 communication performance based on IEC 61850 by measuring delay latency of message transfer on embeded linux system.

Standardization of IEC Terminologies Based on a Matrix Classification System (매트릭스형 분류체계를 적용한 IEC 기술용어 표준화 방안)

  • Hwang, Humor;Kim, Jung-Hoon;Moon, Bong-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.515-522
    • /
    • 2015
  • Through the correspondence works with IEC in the smart grid fields and power IT fields, we set up the interpretation work procedure and defined the work rule for correspondence by analyzing the work results. In addition, we suggest cases for discussion of terms and definitions in the IEC and analyze them and then propose a matrix classification system for standardization to solve the cases for discussion. The matrix classification system with 3-axes of classification has been applied to newly emerging terminologies followed by smart gird. We drew the usefulness in search of terms in application fields and showed the cases of applying the matrix classification. The IEC Electropedia classification standard is unclear and the classification is mixed with principle, application and product areas. We proposed a new working group in IEC TC1 for research on the matrix classification system and then TC 1 decided to organize a new WG titled in the "IEV structure and supporting tools".

Building a Rule-Based Goal-Model from the IEC 62304 Standard for Medical Device Software

  • Kim, DongYeop;Lee, Byungjeong;Lee, Jung-Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4174-4190
    • /
    • 2019
  • IEC 62304 is a standard for the medical device software lifecycle. Developers must develop software that complies with all specifications in the standard for licensing. However, because the standard contains not only a large number of specifications, but also domain-specific information and association relationships between specifications, it requires considerable effort and time for developers to understand and interpret the standard. To support developers, this paper presents a method for extracting the contents of the IEC 62304 standard as a goal model, which is the core methodologies of requirements engineering. The proposed method analyzes the grammar of the standard to robustly extract complex structures and various information from standard specifications and define rules that extract goals and links from syntactic element units. We validated the actual extraction process for the standard document experimentally. Based on the extracted goal model, developers can intuitively and efficiently comply with the standard and track specific information within the medical software and standard domains.

Design of Quality Evaluation Criteria for Component Software (컴포넌트 소프트웨어 품질 평가 모듈 설계)

  • Yoo Ji-Hyun;Lee Byongl-Gul
    • Journal of Internet Computing and Services
    • /
    • v.4 no.1
    • /
    • pp.39-52
    • /
    • 2003
  • As software is developed for many applications and software defects have caused serious problem sin those applications, the concern of software quality evaluation increases rapidly. Although there has been many efforts for establishing standards for software evaluation, such as ISO/IEC 9126, they provide only a framework for defining quality characteristics and evaluation process. They, however, do not provide practical guidances for deriving resonable weight value criteria for software evaluation. This paper presents a method to draw quantitative weight values from evaluator's subjective data in the process of software evaluation as observing the ISO/IEC 9126 standard. To eliminate the evaluators' subjectiveness and the uncertainty of weight value during evaluation, the Dempster-Shafer (D-S) theory is adopted and utilized. In this paper, the D-S theory is supplemented with an improved merge rule to reduce the bias of weight value when they are merged with other evaluator's weight value. The proposed merge rule has been tested and proved with actual evaluation data.

  • PDF

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

The development of RFID multi-codes converter based on ID profiles (ID 프로파일을 이용한 RFID 멀티 코드 변환기 연구)

  • Lee, Chang-Yeol;Mo, Hee-Sook
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.2
    • /
    • pp.124-133
    • /
    • 2009
  • There are many different ID representation forms depending on the media or applications. In case of RFID tag, ID representation form must be followed by the rule of ISO/IEC 15962. In this study, we developed the efficient ID conversion algorithm between ID representation form on RFID tag and Internet. The main idea is on the use of XML based ID profiles and three step logical IDs forms. The algorithm was tested by the typical three kinds of real IDs such as EPC, ISO/IEC 15459 KKR Code, and mCode which are the typical meta-IDs can be defined in ISO/IEC 18000-6C tag.

A Design of Metadata Registry Database based on Object-Relational Transformation Methodology (객체-관계 변환 방법론 기반 메타데이터 레지스트리 데이터베이스 설계)

  • Cha, Sooyoung;Lee, Sukhoon;Jeong, Dongwon;Baik, Doo-Kwon
    • Journal of KIISE
    • /
    • v.42 no.9
    • /
    • pp.1147-1161
    • /
    • 2015
  • The ISO/IEC 11179 Metadata registry (MDR) is an international standard that was developed to register and share metadata. ISO/IEC 11179 represents an MDR as a metamodel that is an object model. However, it is difficult to develop an MDR based on ISO/IEC 11179 because the standard has no clear criteria to transform the metamodel into a database. In this paper, we suggest the design of an MDR data model that is based on object-relational transformation methodology (ORTM) for the MDR implementation. Hence, we classify the transformation methods of ORTM according to the corresponding relationships. After classification, we propose modeling rules by defining the standard use of the transformation. This paper builds the relational database tables as an implementation result of an MDR data model. Through experiments and evaluation, we verify the proposed modeling rules and evaluate the suitability of the created table structures. As the result, the proposed method shows that the table structures preserve classes and relationships of the standard metamodel well.

A Study on Quality Estimation Model from Quality Metrics for BRE(Business Rule Engine) (BRE(Business Rule Engine) 품질평가메트릭을 이용한 품질평가모델에 관한 연구)

  • Chang, Tae-Hwan;Kim, Hyo-Gon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.977-980
    • /
    • 2010
  • 기업내부에 존재하는 비즈니스 룰은 정형화되고 집중화된 하나의 시스템으로 구축되어 있는 것이 아니라 여러 서브시스템이나 실무자의 경험속에 산재되어 존재한다. 산재되어 존재하는 비즈니스 룰을 정형화된 형태로 집중관리가 가능하도록 구축한 도구가 BRE(Business Rule Engine)이다. BRE는 비즈니스 룰 관리를 빠르고 용이하게 하여, 기업의 경쟁력 향상에 매우 효과적인 기여를 한다. 하지만 BRE도입시 고려해야 할 품질특성을 판단할 뚜렷한 기준을 가지고 있지 못 하기 때문에 고가의 솔루션인 BRE도입에 많은 어려움을 겪고 있다. 본 연구에서는 국제 표준 ISO/IEC 9126를 기반으로 BRE가 갖추어야 할 품질특성을 정의하고 BRE 도입시 고려해야 할 품질특성을 판단할 수 있는 판별분석기법을 통해 BRE를 명확히 이해할 수 있는 품질평가모델을 제시함으로서 이러한 문제를 해결하고자 한다. 또한 본 연구의 결과는 실제 구축된 BRE 사례들에 대해 판별분석기법을 통해 검증하며, 검증된 품질평가모델의 활용방안을 제시한다.

Test field for the application of IEC 60364 in Korea (접지규정 IEC 60364의 국내 적용을 위한 실증시험장 구축)

  • Nam, Kee-Young;Choi, Sang-Bong;Ryoo, Hee-Suk;Lee, Jae-Duck;Jeong, Seong-Hwan;Kim, Dae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.116-118
    • /
    • 2005
  • IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standards deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries defines the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for themselves. The background of circuit of IEC 60364 is based on the ungrounded system as most of European countries adopt. However, since domestic ground system is multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364 and to evaluate the standard is applicable or not to domestic rule for the protection against ground fault through the related test.

  • PDF

Design Improvement on Wind Turbine Blade of Medium Scale HAWT by Considering IEC 1400-1 Specification (IEC1400-1 규격을 고려한 중형 수평축 풍력발전용 회전날개의 설계개선 연구)

  • 공창덕;정석훈;장병섭;방조혁
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.3
    • /
    • pp.29-37
    • /
    • 2000
  • Because the previous design procedure for the composite wind turbine blade structure using trial and error method takes long time, a improved design procedure by using the program based on classical laminate theory was proposed to reduce the inefficient element. According to the improved design procedure, limitation of strains, stresses and displacements specified by international standard specification IEC1400-1 for the composite wind turbine blade were applied to sizing the structural configuration by using the rule of mixture and the principal stress design technique with a simplified turbine blade. Structural safety for strength and buckling stability was confirmed by the developed analysis program based on the laminate theory to minimize the design procedure. After modifying the preliminary design result with additional structural components such as skin, foam sandwich and mounting joints, stresses, strains, displacements, natural frequency, buckling load and fatigue life were analyzed by the finite element method. Finally these results were confirmed by comparing with IEC1400-1 specification.

  • PDF