A Fault Diagnosis Method of Oil-Filled Power Transformers Using IEC Code based Neuro-Fuzzy Model (IEC 코드 기반의 뉴로-퍼지모델을 이용한 유입변압기 고장진단 기법)

  • Seo, Myeong-Seok;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using IEC code based neuro-fuzzy model. The proposed method proceeds two steps. First, IEC 60599 method is applied to diagnosis. If IEC code can't determine the fault type, neuro-fuzzy model is applied to effectively classify the fault type. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

Efficient Transformer Dissolved Gas Analysis and Classification Method (효율적인 변압기 유중가스 분석 및 분류 방법)

  • Cho, Yoon-Jeong;Kim, Jae-Young;Kim, Jong-Myon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.563-570
    • /
    • 2018
  • This paper proposes an efficient dissolved gas analysis(DGA) and classification method of an oil-filled transformer using machine learning algorithms to solve problems inherent in IEC 60599. In IEC 60599, a certain diagnosis criteria do not exist, and duplication area is existed. Thus, it is difficult to make a decision without any experts since the IEC 60599 standard can not support analysis and classification of gas date of a power transformer in that criteria. To address these issue. we propose a dissolved gas analysis(DGA) and classification method using a machine learning algorithm. We evaluate the performance of the proposed method using support vector machines with dissolved gas dataset extracted from a power transformer in the real industry. To validate the performance of the proposed method, we compares the proposed method with the IEC 60599 standard. Experimental results show that the proposed method outperforms the IEC 60599 in the classification accuracy.

Designs of the Unified Information Model-IEC61850/IEC61970 and Topology Model for Smart Grid (스마트 그리드 망을 위한 IEC61970/IEC61850 통합 정보 모델과 토폴로지 모델 설계)

  • Yun, Seok-Yeul;Yim, Hwa-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.28-33
    • /
    • 2012
  • The smart grid, which is an integrated type of the power system and the digital network, requires the integration of a CIM(Common Information Model) standard for information modelling at the power control centers and an IEC 61850 standard for automation at the substation level in order to efficiently exchange the information between system elements. This paper describes the method of data transfer from one standard information model to the other standard unified information model by mapping between the objects of IEC 61850 and IEC61970 CIM standards both in the static and dynamic models, and designs the method of data transfer and information exchange between the topology processing application using unified topology class packages.

Development of a Software PLC for PC Based on IEC 61131-3 Standard (IEC 61131-3 표준을 따른 PC용 소프트웨어 PLC의 개발)

  • Lee, Cheol-Soo;Jeong, Gu;Lee, Je-Phil;Sim, Ju-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.61-69
    • /
    • 2002
  • This paper describes a converting algorithm between programmable languages of a software PLU. It is based on IEC 61131-3 standard and PC. The proposed control logic is designed by the software model and common element with data type, variables, POUs(program organization unit) and execution control unit commonly used within programmable languages of IEC 61131-3 Standard. The generation method of object file is proposed on five programmable language based on IEC 61131-3. It is represented as fo11ows; 1) the generation method using conversion algorithm from LD to IL with FBD(function block diagram), 2) the generation method using f code generation algorithm from SFC using the SFC execution sequence with FBD and ST(structured text). The proposed control logic generator was implemented by Visual C++ 6.0 and MFC on MS-windows NT 4.0.

The New Aging Diagnosis in IEC-60587 (IEC-60587의 새로운 열화진단)

  • Lim, Jang-Seob;Chung, Seung-Chun;Jeong, Jong-Cheol;Park, Gye-Choon;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.71-74
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used In surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

A Study of the Data Qualituy Evaluation (데이터 품질 평가에 관한 연구)

  • Jung, Hye-Jung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.4
    • /
    • pp.119-128
    • /
    • 2007
  • In this paper, We study on the Data Quality Model of ISO/IEC 25012 among the Software product Quality Requirements and Evaluation(SQuaRE) in ISO/IEC 25000 Series. Because of the increasing data, user require the accuracy data, recent data, suitable data for used tools, complied security and not open to be public. We research the data quality management in the point of application of be affect influenced low quality in business. We propose the testing items and we propose the method of the evaluation proposed testing items. We study on the basis international Standards ISO/IEC 25012 and ISO/IEC 9126-2 and we proposed the testing method quantitatively on the basis of ISO/IEC 25000.

  • PDF

The Configuration Method of trip logic for IEC 61850 based IED using XML (IEC 61850 기반 IED의 XML을 이용한 트립로직 구성)

  • Go, Chol-Jin;Jin, Yong-Woo;Kim, Kyong-Taek;Kim, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.315-316
    • /
    • 2006
  • As IEC 61850 based substation automation technology is emerging globally, there are many efforts to implement and apply this IEC 61850 standard to substation automation area. IEC 61850 based substation supports ethernet network, standard data model and SCL(substation Configuration Language), etc. These features can provide enough environment to make applied technology which can substitute the legacy relay trip logic configuration method(PLC or Local area reconstruction) to XML based configuration method. This paper suggests new IED trip logic configuration method. The XML based trip logic configuration method can be established using SCL technology And IED trip logic reconfiguration from remote center can be possible under ethernet based technology

  • PDF

A Study on Communication Controller of Electric Vehicle Supply Equipment for Information Exchange between Electric Vehicle and Power Grid (전기차와 전력계통의 정보교환을 위한 전기차 충전장치의 통신 제어기에 대한 연구)

  • Han, Ah;Shin, Minho;Kim, Intaek;Jang, Hyuk-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1564-1570
    • /
    • 2014
  • An electric vehicle (EV) not only receives electric power from the electric vehicle supply equipment (EVSE), but it also exchanges the information regarding charging process with the power gird through the EVSE. However, the EV and EVSE communicate using the ISO/IEC 15118 standard while the EVSE and power grid communicate using the IEC 61850 standard. Therefore, the EVSE should support both the ISO/IEC 15118 and IEC 61850 standards, and provide a data mapping function between the two communication protocols so that the EV and power grid, which support different protocols, can communicate with each other throughout the charging process. In this paper, we propose a mapping method of the EVSE, which converts the ISO/IEC 15118 data to IEC 61850 and vice versa, based on the XML schema of each protocol. The proposed method converts the data using the XSL (eXtensible Stylesheet Language) method, which defines the data mapping between two XML schemas. Our approach is more flexible and easier to maintain against changes in charging scenarios and the standards than other existing approaches such as one-to-one data mapping methods.

An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364 (IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사)

  • Jung, Jin-Soo;Han, Woon-Ki;Lee, Han-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.36-41
    • /
    • 2009
  • In this paper an Investigation into the actual condition of electrical equipment installation for the inspection method development based on IEC 60364. The analysis objects are the difference between electrical equipments installation in korea & electrical equipments installation based on the IEC 60364. The measurement elements are loop impedance, operating characteristic of circuit breaker and protective conductor continuance. As a result, the korea electrical equipments installation was almost same the TT system but some different of protective conductor continuance. Electrical equipments installed TN-C-S has noting problem about installation but manager dose not understand about IEC 60364.

Improvement of Anti-Collision Performance in ISO/IEC 18000-6 Type B Protocol of the 900MHz RFID System (900MHz RFID 표준 프로토콜(ISO/IEC 18000-6 type B)에서의 충돌방지 성능 개선)

  • Kwon Dae-Ken;Kim Wan-Jin;Kim Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5C
    • /
    • pp.540-547
    • /
    • 2006
  • This paper proposes a novel anti-collision method for the ISO/IEC 18000-6 type B protocol which is the standard protocol of the 900 MHz RFID system. We improve the anti-collision performance by reducing the transmission number of commands and the length of bits required for multi-tag identification in the ISO/IEC 18000-6 type B protocol. Simulation results show that the proposed method improves the multi-tag identification time by 21.7% over the conventional method, irrespective of number of tags.