• Title/Summary/Keyword: IEC 62471

Search Result 3, Processing Time 0.016 seconds

Analysis on IEC 62471 for The Introduction of Photobiological Safety of LED Lamp (LED조명의 광생물학적안전성 도입을 위한 IEC 62471 규격 분석)

  • Ko, Jae-Kyu;Cho, Mee-Ryoung;Lee, Min-Jin;Kim, Ju-Hyun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.435-443
    • /
    • 2012
  • First introduced in 1962, LED(light-emitting diodes) emitted low-intensity red light, but modern versions are now available across the ultraviolet, visible, and infrared spectrum, many with very high luminance or brightness. As a result, growing importance of potential safety harzards for human. Now when certificated of CE provide that testing through IEC/EN 62471 for any lamp. Korea standard adopted as it IEC 62471:2006, Photobiological safety of lamps and lamp systems without change, but effectiveness is incomplete. In this paper, we introduce analysis and direction that urgently come into effectiveness of KS C IEC 62471 as a national standard specifications.

  • PDF

Evaluation of Blue Light Hazards in LED Lightings (LED 조명에 대한 청색광 위험 평가)

  • Jung, Myoung Hoon;Yang, Seok-Jun;Yuk, Ju Sung;Oh, Sang-Young;Kim, Chang-Jin;Lyu, Jungmook;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.293-300
    • /
    • 2015
  • Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.

Blue-Light Hazards of 405 nm Sterilization LED Lamps (405 nm 살균용 UV LED 등기구의 청색광 위해에 관한 연구)

  • Hyeon-seok Heo;Chung-hyeok Kim;Ki-ho Nam;Jin-sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.266-274
    • /
    • 2023
  • Recently, sterilization technology has received increasing interest due to the COVID-19 pandemic and required safety precautions. Particularly, sterilization devices using near ultraviolet (UV) with a 405 nm wavelength are also drawing attention. It has a UV-C wavelength and other sterilization effects. Its blue-colored light on the boundary between UV and visible light is used as a light-emitting diode (LED) lamp for 405 nm sterilization, owing to its longer wavelengths than UV rays. However, the 405 nm wavelength contains blue light that can damage the eyes and skin during prolonged exposures and affect the emotional and biological parts of the body. Currently, 405 nm sterilization LED light registers are circulating in the market. However, they have not undergone safety tests for blue-light hazards. Thus, with the active distribution of sterilization LED lights, solid safety standards and management systems are essential to protect users from blue-light hazards. Accordingly, in this study, we conducted spectral radiance and spectral radiative luminance tests on 405 nm sterilization LED registers available in the market by the measurement criteria of IEC 62471. Safety standards must be established to secure users' safety against blue light hazards at a time when 405nm sterilization LED lights are actively distributed due to COVID-19.