• Title/Summary/Keyword: IEC 601-1

Search Result 4, Processing Time 0.022 seconds

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF

The development standard research for railway safety software (철도 안전 소프트웨어를 위한 개발 기준 연구)

  • Lee, Young-Jun;Kim, Jang-Yoel;Cha, Kyung-Ho;Cheon, Se-Woo;Lee, Jang-Soo;Kwon, Ki-Choon;Jung, Ui-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.968-973
    • /
    • 2007
  • The systems such as the railway control system, satellite control system and nuclear power plant control system are the safety critical systems because the failure of them could lead to risk significant events. These softwares of digital systems must follow the life cycle process from the beginning of software development to guarantee their safety and reliability. The NRC(Nuclear Regulatory Commission) Reg Guide of nuclear fields, the RTCA/DO-178B standard which is used to acquire the certification for software in industrial aero field in European Union and United State, the DEF STAN 00-55 standard for the safety of electronic weapon in England, the IEC 601-1-4 for medical equipment and the IEC 62279 for railway system recommended the development life cycle. This paper introduces the development process and compares each other. Also it indicates applicable development criteria for the software of systems related to railway fields and describes the detailed procedure of development criteria. We describe the procedure to make the software development criteria in nuclear filed. For the software development related to railways, the process from plan phase to maintenance phase must be satisfied. The safety and reliability is guaranteed through these standards.

  • PDF

Degradation of Nafion Membrane by Oxygen Radical (산소 라디칼에 의한 Nafion 막의 열화)

  • Kim, Taehee;Lee, Junghun;Cho, Gyoujin;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.597-601
    • /
    • 2006
  • The degradation of the Nafion membrane by oxygen radical (OH, $HO_2$) was investigated in Polymer electrolyte membrane fuel cell (PEMFC). Nafion membrane was degraded in Fenton solution consisted with hydrogen peroxide (10-30%) and ferrous ion (1-4 ppm) at $80^{\circ}C$. After degradation in Fenton solution, C-F, S-O and C-O chemical bonds of membrane were broken by oxygen radical attack. Breaking of C-F bond reduced the mechanical strength of Nafion membrane, and hence induced pinholes, resulting in increase of $H_2$ crossover through the membrane. Decomposition of S-O and C-O bonds decreased the ion exchange capacity of the electrolyte membrane. The performance of unit cell composed the membrane, which was degraded in 30% $H_2O_2$ with 4ppm $Fe^{2+}$ solution for 48 hr, was about half times as low as one with normal membrane.

Development of Standards of Tattoo Machine for Safety and Performance Evaluation (의료용 표시기의 안전성 및 성능 평가를 위한 시험 항목 및 시험방법(안)연구)

  • Kim, Y.G.;Cho, S.K.;Lee, T.W.;Yeo, C.M.;Jung, B.J.;Kwon, Y.M.;Cha, J.H.;Hur, C.H.;Park, K.J.;Kim, D.S.;Kim, H.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.151-157
    • /
    • 2011
  • Tattooing is a performance for decorative and cosmetic marking by placing permanent ink into the skin. As the cultural meaning of tattoo in Korea is changing, the tattoo machines are widely spread n permanent cosmetic market. Though the use of the tattoo machine was increased, the evaluation standards of tattoo machine were not existed. Korea Food and Drug Association regulated the electrical and mechanical safety standards which were founded on the IEC 601-1 second edition. Also they regulated he biological safety standards which were derived from the ISO 10993 series, however, these general valuations of common medical device were insufficient for evaluating tattoo machine. We developed the standards of tattoo machine for safety and performance evaluation for tattoo machine by preliminary hazard analysis in ISO 14971. The evaluation criteria of tattoo machines are focused on the mechanical invasion. We suggested the additional evaluation items of the needle speed, length, vibration with general valuation criteria of common medical device. We anticipate that this research may be a primary stage to figure a standard regulation and evaluation for tattoo machine.