• Title/Summary/Keyword: ICP analysis

Search Result 819, Processing Time 0.033 seconds

Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS (INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

Quantitative Analysis of Trace Metals in Lithium Molten Salt by ICP-AES (ICP-AES를 이용한 리튬 용융염내의 미량 금속성분원소 정량에 관한 연구)

  • Kim, Do-Yang;Pyo, Hyung-Yeal;Park, Yong-Joon;Park, Yang-Soon;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.309-314
    • /
    • 2000
  • The quantitative analysis of various trace metals including fission products in lithium molten salts has been performed using a inductively coupled plasma atomic emission spectrometer (ICP-AES). The spectral interferences of lithium content, 500, 1,000 and 2,000 mg/L, in the sample solution were investigated using an optimum wavelength for the respective metal species. As a result, the line intensities for Y, Nd, Sr, and La had no influences from the lithium content up to 2,000 mg/L, while Mo, Ba, Ru, Pd, Rh, Zr and Ce showed spectral interferences of 10% to 50%. The group separation of metals from lithium in the molten salts solution was carried out by adding ammonia water into the solution. The recovery of Ru, Y, Rh, Zr, Nd, Ce, La and Eu was found to be over 90%, while Mo, Ba, Pd, and Sr provided low recovery percentages.

  • PDF

Development and Round Robin Test of Pt-Co Alloy Thin Film Standard Materials for the Quantification of Surface Compositional Analysis (표면 조성분석의 정량화를 위한 Pt-Co 합금박막 표준시료의 개발 및 공동분석)

  • 김경중
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.176-186
    • /
    • 1998
  • Pure Pt, Co and their alloy thin films with three different compositions (Pt66-Co34, Pt40-Co60 and Pt18-Co82) were deposited on Si(100) wafers and proposed as a set of certified reference materials (CRM) for the quantification and standardization of surface compositional analysis. The compositions of the binary alloy thin films were controlled by in-situ XPS analyses and the certified compositions of the films have been determined by ICP-AES and RBS analyses after thin film growth. Through comparison of the compositions determined by in-situ XPS with those by ICP, relatively accurate compositions could be obtained with a matrix effect correction. Standard deviations of XPS and AES round robin tests with the Pt-Co alloy thin films were large up to about 4%. On the other hand, the average compositions of the Pt-Co alloy thin films by two methods were in a good agreement within 1%. The formation of a Pt rich surface layer by ion beam sputtering indicates that the surface modification by preferential sputtering must be understood for a better compositional analysis.

  • PDF

Studies on Heavy Metal Dissolution Characteristics from Sediments of Andong Dam (안동댐 퇴적물의 중금속 용출 특성 연구)

  • Seo, Jeong Min;Kim, Young Hun;Kim, Jeong Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.303-312
    • /
    • 2019
  • In this study, X-ray diffraction, ICP analysis, and leaching experiments were performed to analyze the heavy metals and dissolution characteristics of Andong dam sediments. As a result of X-ray diffraction analysis, Andong dam sediment consists of quartz, plagioclase, chlorite and illite. ICP analysis of sediment showed very high concentrations of As and Cd. Leaching experiments were performed in aerobic and anaerobic condition in a disturbed state. The results of leaching experiment showed that more heavy metals were leached in aerobic than anaerobic conditions. Heavy metal that increased in concentration with time in aerobic conditions were Mn, Zn and Cd, and those in anaerobic conditions were Mn, Fe and As. The leaching ratio of heavy metal concentration in sediment was Mn > Cd > Zn > Ni > Cu > As > Pb ≒ Fe ≒ Cr and Mn > As > Cu > Ni > Zn > Pb ≒ Cd ≒ Fe ≒ Cr in aerobic and anaerobic conditions, respectively.

Improving Strontium Isotope Ratio Analysis Using MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 스트론튬 동위원소비 분석법 개선)

  • Lee, Sin-Woo;Park, Jaeseon;Park, Hyun-Woo;Hwang, Jong Yeon;Kim, Kumhee;Chung, Hyun-Mi;Choi, Jong-Woo
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.237-242
    • /
    • 2018
  • Strontium (Sr) commonly exists in rock, groundwater, soil, plants, and animals. The Sr isotope ratio offers important information as a tracer on nature because the Sr isotopic composition is not fractionated by any biological process in these ecosystems. Hence, Sr isotope ratio has been used in several studies on tracing the Sr source for contaminated sites and human migration. In this study, we developed a separation method for Sr content, and then improved Sr isotope analysis using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). A powdered rock standard (NIST 2710a) was used to determine the removal of interference elements (Rb and Ca) and the recovery rate of Sr content. The results ranged from 98% to 106%. Additionally, three standard samples (NBS 987, IAPSO and NIST 1486) were analyzed to evaluate the precision and accuracy of the results. The measured $^{87}Sr/^{86}Sr$ ratio for all the samples were consistent with the reported values, within an error. These results indicate that our established Sr separation and Sr isotope measurement methods are reliable and can hence be useful in the fields of environmental and forensic sciences.

Simultaneous Determination of Sulfur, Phosphorus, and Zine in Lubricating Oils by Microwave Digestion System and ICP-AES (마이크로파 분해장치와 유도결합 플라스마 원자방출분광법을 이용한 윤활유 시료 중 S, P 및 Zn의 동시 분석)

  • Cho, Sung-Ill;Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.324-330
    • /
    • 2001
  • For the analysis of S, P and Zn in lubricating oil, microwave digestion method was studied by using inductively coupled plasma-atomic emission spectrometry(ICP-AES). Lubricating oil was completely decomposed with nitric acid or a mixture of nitric acid and hydrogen peroxide using and closed microwave digestion system. Digestions are completed within 50 min, a factor of at least 3~4 times faster than for the conventional digestion. A gradual heating program operated by the pulsed mode was found suitable for decomposing the lubricating oil matrix safely. The proposed method of digestion gave relative standard deviations(RSD) less than 3% for the elements determined.

  • PDF

Adsorptive Preconcentration and ICP-AES Determination for Trace Amount of Ni(II) and Zn(II) in Aqueous Solution (수용액 중 극미량 니켈(II)과 아연(II)의 흡착농축 및 ICP-AES 정량에 관한 연구)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.73-78
    • /
    • 2005
  • A determination method of trace Ni(II) and Zn(II) in aqueous solution was studied and developed by adsorbing on titanium dioxide. For this purpose, several conditions were optimized such as the pH of sample solution, adsorption time, the types and concentration acid, and desorption time. The titanium dioxide was added in sample solution which was pH adjusted. Then, the sample solution was stirred for 5 minutes. This mixture was stored in room temperature for 30 minutes to allow adsorption. After filtering and washing the titanium dioxide, the analytes were dissolved from the titanium dioxide on membrane filter by an ultrasonic vibration for 10 minutes in 1.0 M $HNO_3$ solution. Then, this sample solution was analysed using ICP-AES. The adsorption equilibrium was achieved in 30 minutes. The desorption was the most of effective with 1.0 M(mol/l) nitric acid solution, and desorption time was 10 minutes. This procedure was applied for the analysis of two real samples, i.e., brown seaweed and tangle. The recoveries of Ni(II) and Zn(II) in spiked samples were 89.4${\sim}$98.9% for analytes.

3D Shape Analysis for the Hippocampus Using ICP Registration and Neural Networks (ICP 정합과 신경망을 이용한 해마의 3차원 형상 분석)

  • Kim, Jeong-Sik;Choi, Soo-Mi;Kim, Yong-Guk;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.10 no.4
    • /
    • pp.27-36
    • /
    • 2004
  • 본 논문에서는 뇌의 하부구조인 해마를 정확하게 분석하기 위한 형상 정규화 방법과 정상인과 간질 환자의 해마를 분류하기 위한 방법을 제시한다. 해마에 대한 형상 분석 과정은 크게 형상 표현을 구축하는 과정, 형상의 유사도를 측정하는 과정, 정상인 집단과 환자 집단을 분류하는 과정으로 이루어진다. 본 연구에서는 해마의 형상 표현으로 메쉬, 골격, 복셀로 이루어진 하이브리드 옥트리 자료구조를 구축하였다. 또한 Iterative Closest Point (ICP) 알고리즘을 사용하여 해마 골격을 기반으로 한 정규화를 수행하였다. 그리고 정규화된 해마 형상을 전역적, 국부적으로 분석하여 최종적으로 입력된 해마가 정상인 또는 간질 환자에 속하는지를 학습된 데이터를 이용하여 분류하였다. 본 논문에서 제시한 ICP 기반의 정규화 방법은 3차원 해마 형상을 정확하게 분석하게 해주고, 골격의 정점 수를 조절함으로써 정규화 시간을 감소시킬 수 있다. 뿐만 아니라 3차원 해마 모델의 형상을 신경망을 통하여 학습시킴으로써 해마의 형상이 변형된 환자 집단과 정상인 집단을 분류하는데 이용할 수 있다.

  • PDF

Toxic Trace and Earth Crustal Elements of Ambient PM2.5 Using CCT-ICP-MS in an Urban Area of Korea

  • Lee, Jin-Hong;Jeong, Jin-Hee;Lim, Joung-Myung
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Collision cell technology-inductively coupled plasma-mass spectrometry (CCT-ICP-MS) was used to measure the concentrations of approximately 19 elements associated with airborne PM2.5 samples that were collected from a roadside sampling station in Daejeon, Korea. Standard reference material (SRM 2783, air particulate on filter media) of the National Institute of Standards and Technology was used for the quality assurance of CCT-ICP-MS. The elemental concentrations were compared statistically with the certified (or recommended) values. The patterns of distribution were clearly distinguished between elements with their concentrations ranging over four orders of magnitude. If compared in terms of enrichment factors, it was found that toxic trace elements (e.g., Sb, Se, Cd, As, Zn, Pb, and Cu) of anthropogenic origin are much more enriched in PM2.5 samples of the study site. To the contrary, the results of the correlation analysis showed that PM2.5 concentrations can exhibit more enhanced correlations with the elements (e.g., Fe, K, Si, and Ti) arising from earth's crust. The findings of strong correlations between PM2.5 and the elements of crustal origin may be directly comparable with the dominant role of those species by constituting a major fraction of even PM2.5 as well as PM10 at the roadside area.