• Title/Summary/Keyword: ICP/Mass

Search Result 356, Processing Time 0.026 seconds

Analytical Techniques Using ICP-MS for Clinical and Biological Analysis

  • Ko, Jungaa;Lim, H. B.
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.85-90
    • /
    • 2015
  • This article reviews recent analytical techniques using inductively coupled plasma-mass spectrometry (ICP-MS) immunoassay for clinical and bio analysis. We classified the techniques into two categories, direct and indirect analysis, which depend upon a guideline of whether tagging materials are used or not. Direct analysis is well known, and generally used in conjunction with various other techniques, such as laser ablation, chromatographic separations, etc. Recently, indirect analysis using tagging elements has intensively been discussed because of its importance in future applications to bio and clinical analysis, including environmental and food industries. The method has shown advantages of multiplex detection, excellent sensitivity, and short analysis time owing to signal amplification and magnetic separation. Now, it expands the application field from small biomolecules to large cells.

Determination of Trace Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라즈마 질량분석기를 이용한 동물사료중의 극미량원소의 분석)

  • Park, Jeoung-Hwa;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.199-204
    • /
    • 1992
  • The trace elements in animal feed were analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS, VG-PlasmaQuad Co.) to find possible sources of heavy metals accumulation in rat organ. The study about spectral interference was performed by analysis of a background spectrum of ICP-MS. Recovery test using standard of Cd and Se (100 ppb) was found to be better than 90%. Twenty elements (Ca, Fe, Mg, Ti, Cr, Ni, Cu, Zn, Ba, Al, Mn, Pb, B, Ce, Bi, U, V, Cd, and W)are determined.

  • PDF

Direct Analysis of Aerosol Particles by Atomic Emission and Mass Spectrometry

  • Kawaguchi, Hiroshi;Nomizu, Tsutomu;Tanaka, Tomokazu;Kaneco, Satoshi
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.411-418
    • /
    • 1995
  • A method for the direct determination of elemental content in each of aerosol particles by inductively coupled plasma atomic emission (ICP-AES) or mass spectrometry (ICP-MS) is described. This method is based upon the introduction of diluted aerosol into an ICP and the measurement of either the flash emission intensities of an atomic spectral line or ion intensities. A pulse-height analyzer is used for the measurement of the distribution of the elemental content. In order to calibrate the measuring system, monodisperse aerosols are used. The potentials of the method are shown by demonstrating the copper emission signals from the aerosols generated at a small electric switch, a study of the relation between the decreasing rate of particle number density and particle size, and measurements of calcium contents in the individual biological cells.

  • PDF

Tandem laser-induced breakdown spectroscopy laser-ablation inductively-coupled plasma mass spectrometry analysis of high-purity alumina powder

  • Lee, Yonghoon;Kim, Hyang
    • Analytical Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.121-130
    • /
    • 2019
  • Alumina is one of the most important ceramic materials because of its useful physical and chemical properties. Recently, high-purity alumina has been used in various industrial fields. This leads to increasing demand for reliable elemental analysis of impurities in alumina samples. However, the chemical inertness of alumina makes the sample preparation for conventional elemental analysis a tremendously difficult task. Herein, we demonstrated the feasibility of laser ablation for effective sampling of alumina powder. Laser ablation performs sampling rapidly without any chemical reagents and also allows simultaneous optical emission spectroscopy and mass spectrometry analyses. For six alumina samples including certified reference materials and commercial products, laser-induced breakdown spectroscopy (LIBS) and laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) analyses were performed simultaneously based on a common laser ablation sampling. LIBS was found to be useful to quantify alkali and alkaline earth metals with limits-of-detection (LODs) around 1 ppm. LA-ICP-MS could quantify transition metals such as Ti, Cu, Zn, and Zr with LODs in the range from a few tens to hundreds ppb.

The chemical speciation and analysis of trace elements in sediment with neutron activation analytical method(NAA) and atomic mass spectrometry (중성자 방사화분석법과 원자질량분석법을 이용한 침전물 시료속에 존재하는 미량원소들의 화학종 분류 및 분석)

  • Nam, Sang-Ho;Kim, Jae-Jin;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.358-367
    • /
    • 2003
  • In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will play an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA.

A study on the determination of lead in whole blood by ICP/MS (ICP/MS에 의한 전혈 중 납의 분석방법 연구)

  • Park, Kyung Su;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.240-245
    • /
    • 1997
  • An accurate analysis method for the determination of lead in whole blood by ICP/MS was developed. Whole blood samples were decomposed in microwave digestion system without any contamination and loss of lead. The 96 samples were analyzed by ICP/MS using mass$^{208}$ isotope of lead. Lead concentrations of human whole blood were ranged of $2.50{\sim}22.8{\mu}g/dL$. The accuracy of this analysis method was verified by analyzing of NIST SRM 955a series(lead in blood).

  • PDF

High sensitivity determination of iridium contents in ultra-basic rocks by INAA with coincidence gamma-ray detection

  • Ebihara, Mitsuru;Shirai, Naoki;Kuwayama, Jin;Toh, Yosuke
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.423-428
    • /
    • 2022
  • Very low contents (in the range of 10-9 g/g) of Ir in mantle-derived rock samples (komatiites) were non-destructively determined by INAA coupled with coincidence gamma-ray spectrometry using 16 Ge detectors. Aliquots of the same samples were analyzed by NiS fire-assay ICP-MS for Ir and other platinum group elements. Because the INAA procedure used in this study is non-destructive and is almost free from spectral interference in gamma-ray spectrometry, the INAA values of Ir contents obtained in this study can be highly reliable. Iridium values obtained by ICP-MS were consistent with the INAA values, implying that the ICP-MS values of Ir obtained in this study are equally reliable. Under the present experimental conditions, detection limits were estimated to be 1 pg/g, which corresponds to 0.1 pg for a sample mass of 0.1 g. These levels can be even lowered by an order of magnitude, if necessary, which cannot be achieved by ICP-MS carried out in this study.

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교)

  • Kang, Min-Kyung;Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Feasibility Study of Isotope Ratio Analysis of Individual Uranium-Plutonium Mixed Oxide Particles with SIMS and ICP-MS

  • Esaka, Fumitaka;Magara, Masaaki;Suzuki, Daisuke;Miyamoto, Yutaka;Lee, Chi-Gyu;Kimura, Takaumi
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.80-83
    • /
    • 2011
  • Isotope ratio analysis of nuclear materials in individual particles is of great importance for nuclear safeguards. Although secondary ion mass spectrometry (SIMS) and thermal ionization mass spectrometry (TIMS) are utilized for the analysis of individual uranium particles, few studies were conducted for the analysis of individual uranium-plutonium mixed oxide particles. In this study, we applied SIMS and inductively coupled plasma mass spectrometry (ICP-MS) to the isotope ratio analysis of individual U-Pu mixed oxide particles. In the analysis of individual U-Pu particles prepared from mixed solution of uranium and plutonium standard reference materials, accurate $^{235}U/^{238}U$, $^{240}Pu/^{239}Pu$ and $^{242}Pu/^{239}Pu$ isotope ratios were obtained with both methods. However, accurate analysis of $^{241}Pu/^{239}Pu$ isotope ratio was impossible, due to the interference of the $^{241}Am$ peak to the $^{241}Pu$ peak. In addition, it was indicated that the interference of the $^{238}UH$ peak to the $^{239}Pu$ peak has a possibility to prevent accurate analysis of plutonium isotope ratios. These problems would be avoided by a combination of ICP-MS and chemical separation of uranium, plutonium and americium in individual U-Pu particles.

Application of Spectrochemical Analysis in the Study of Archaeological Textiles (복식유물의 연구에 있어서 분광화학분석의 활용)

  • 안춘순
    • Journal of the Korean Society of Costume
    • /
    • v.49
    • /
    • pp.49-63
    • /
    • 1999
  • This research utilized the Energy Dispersive X-ray Spectroscopy(EDS) and the Inductively Coupled Plasma Mass Spectrometry in the analysis of chemical elements present among the textiles exhumed from Kupori Hwasung-kun Kyunggi-do. The two research objectives were: first to examine the elements present and their percent presence in Kupori samples: second to investigate whether the elements are part of mordant substances which could have been used when dyeing the KUpori textiles in the past. To meet such research purposes standard silk fabric was dyed with Sophorajaponica using alum and iron mordants. For alum mordant unpurified general alum and potassium aluminum sulfate(AlK(SO4)2). iron sulfate(FeSO4·7H2O) were used, From the results of EDS and ICP-Mass analysis the following conclusions were drawn. 1 According to the EDS analysis 9 elements Ca, S, Al, Si, K, Fe, P, Mg and Na were detected. 2. ICP-Mass result of the mordant chemicas showed high amount of A, Al and k present in alum mordants and S and Fe present in iron mordants. 3. Comparison of the ICP-Mass results of the mordant chemicals and those of the standard dyed samples suggested that the amount presence of Al and Fe is a strong indication of the usage of alum and iron mordants respecticely in an unknown dyed textile. 4, In the washed Kupori textiles Fe showed a relatively higher rate of presence in the samples Therefore it can be conjectured that those Kupori textiles were dyed with iron mordant based on the result of the above number 3. 5. It is probable that the other elements detected from the Kupori samples were incorporated into the textiles as part of the soil debris produced from the degradation of the dead within the coffin or the earth debris. They can also be part of the inorganic compounds inherent in the silk textiles themselves before dyed. 6. Among the elements it is likely that Ca which showed a high degree of presence among the unwashed samples was part of the inorganic compound inferent in the silk textiles.

  • PDF