• Title/Summary/Keyword: ICC Model

Search Result 70, Processing Time 0.021 seconds

ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH (Cone-beam computed tomography를 이용한 미맹출 영구치의 계측)

  • Kim, Seong-Hee;Kim, Young-Jong;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.139-144
    • /
    • 2012
  • The purpose of this study was to evaluate the accuracy and reproducibility of measuring the size of unerupted permanent tooth via cone beam computed tomography(CBCT). Ten children were scanned with dental CBCT, and 3-dimensional reconstruction of the dentitions were generated CBCT. Mesio-distal dimension and buccolingual dimension of the teeth were made directly on the model with a high-precision digitalcaliper and on the CBCT by using three-dimensional dental imaging software. Reliability and accuracy were assessed by using intraclass correlation and paired $t$-tests. ($p$ <0.05) The results were as follows : 1. Intraclass correlations were above 0.9 for Both the CBCT and the model measurements, showinghigh reliability. 2. Although there were high correlation values(r=0.91) between CBCT and model messurement methods, comparisons between the CBCT and model messurement methods showed a statistically significant difference($p$ <0.05). 3. The CBCT measurements tended to slightly underestimate by 0.2 mm. But, the systematic difference of CBCT measurements were clinically acceptable Therefore, CBCT measurement method can be used to measure the size of unerupted teeth in a sufficiently accurate way.

The Applicability of the UNIDROIT Principles as the "Lex Mercatoria" in International Commercial Arbitration (국제상사중재에서 UNIDROIT 원칙의 적용가능성에 관한 연구)

  • Lee, Dae-Jin;Yu, Byoung-Yook;Oh, Hyon-Seok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.21
    • /
    • pp.129-151
    • /
    • 2003
  • Nowadays even if environment of international commercial transaction is changing quickly municipal law could not meet with such change accordingly. So far, however, efforts towards unification have prevailingly taken the form of binding instruments, such as non-national or supranational legislation, international conventions or international model laws. Among them, the UNIDROIT Principles with parties' autonomous and yet non-binding character do not only meet the substantive requirements of a true law merchant. In addition they also counter some of the main points of criticism against the modern lex mercatoria. As such the Principles constitute a cornerstone in the lex mercatoria debate and may become the heart of the new lex mercatoria. The purpose of this article is to ask whether there could be applied the Principles in international commerce. For the purpose it is to investigate when the Principles are applied in international commerce and how effectively the Principles are applied for the decision in international commercial disputes. Even though the Principles are used for reference by parties involved for the voluntary regulation of their contract, it is sufficiently expected that the Principles are to be a stepstone of uniform contract law in international commerce. Until now cases of appling the Principles are not satisfied with its expectation as a source of non-legislative means of unification or harmonization of law. Given the party's autonomy in the contract, this is among other things because business parties are strongly tend to observe their national laws in their international commerce. And also, even though there are a number of neutral and uniform regulations for international commercial contracts, parties do not often recognize their usefulness with being up to expectation. In order to explore the applicability of the Principles a number of cases of ICC International Court of Arbitration and others are quoted.

  • PDF

A Study on the Precautions in light of practical affairs related to a claim for damages under the International Sale of Goods - Focusing on the CISG(1980) and PICC(2004) - (국제물품매매에서 손해배상과 관련한 실무상 유의점에 관한 연구 - CISG(1980)와 PICC(2004)를 중심으로 -)

  • Hwang, Ji-Hyeon;Choi, Young-Joo
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.55
    • /
    • pp.155-181
    • /
    • 2012
  • This study considered as precautions in light of practical affairs related to a claim for damages focusing on CISG (1980) and PICC (2004). Given summarizing contents of this study, those are as follows. First, when exercising a claim for damages, proving the damages may be difficult and hard. Thus, there is necessity for stating the liquidated damages clause in contract given conclusion of contract. Second, as for the application of interest rate given a claim for interest, CISG is not covered interest rate. PICC is covered interest rate. However, there is possibility that PICC will not be applied as general principles. Thus, to remove this insecurity and uncertainty, there is necessity for stating this in contract by deciding on the detailed standard stipulation after fully discussing about interest payment with the counterpart given sale contract. Third, when a seller delivered non-conformity of the goods for contract, a buyer is desirable to exercise by discreetly judging the exercise method or limitation element on a problem of selecting and exercising remedy favorable to oneself out of a claim for damages and a right to reduce the price. Finally, There was suggestion that the contract parties are desirable to utilize by modifying and supplementing properly this in line with own business-based necessity and situation based on the ICC Model International Sale Contract, and to state CISG and PICC the governing law clause, in preparing contract. This study is expected to possibly become guideline in which the damaged party exercises a claim for damages or aims to cope with the counterpart's exercising a claim for damages.

  • PDF

The characteristics of the ISP 98 and the comparison of the ISP 98 and the UCP 600 (ISP98의 특성과 UCP600과의 비교연구)

  • Park, Sae-Woon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.41
    • /
    • pp.51-78
    • /
    • 2009
  • The ISP 98 is developed by the American Institute of International Banking Law & Practice in 1998. The ISP98 are also published as ICC Publication No. 590. A detailed commentary on the rules("The Official Commentary on the International Standby Practice") has been written by Professor James E. Byrnes. Presently there is no compelling reason to revise the rules themselves even if ten years is passed since the issuance of ISP98. Insteadthe American Institute of International Banking Law & Practice will provide Model Forms in the early 2009. Special features of the ISP 98 are as the following. Firstly, the ISP 98 is copyrighted by the Institute of International Banking Law and Practice, Inc., and published by the International Chamber of Commerce. Secondly, the ISP 98 differs from UCP in style and approach because it must receive acceptance not only from bankers and merchants, but also from a broader range of those actively involved in standby law and practice corporate treasurees and credit manager, rating agencies, government agencies and regulators, and indenture trustees as well as their counsel. Because standbys are often intended to be available in the event of disputes or applicant insovency, their texts are subject to a degree of scrutiny not encountered in the commercial letter of credit context. Thirdly, the ISP 98 supplement the UCP if the UCP dose not have the relative rule. Lastly, the ISP 98 has the official commentary. In addition, several provision of the ISP 98 would surprise the commercial parties and/or are rather peculiar, while some of them display a certain bias in favor of the banks.

  • PDF

Development and Psychometric Evaluation of the Transcultural Self-efficacy Scale for Nurses (간호사의 범문화효능감 측정도구 개발 및 타당화)

  • Oh, Won-Oak;Park, Eun Sook;Suk, Min Hyun;Im, Yeo Jin
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.2
    • /
    • pp.293-304
    • /
    • 2016
  • Purpose: This methodological study was conducted to develop and psychometrically test the Transcultural Self-efficacy scale (TCSE-scale) for nurses. Methods: Initial 41 items for the TCSE-scale were generated based on extensive literature reviews and in-depth interviews with 18 nurses who had experience in caring for foreign patients. Cultural Competence and Confidence model was used as a conceptual framework. Content validity was evaluated by an expert panel. Psychometric testing was performed with a convenience sample of 242 nurses recruited from four general hospitals in the Seoul metropolitan area and Gyeonggi-do province of South Korea. To evaluate the reliability of TCSE-scale, a test-retest reliability and an internal consistency reliability were analyzed. Construct validity, concurrent validity, criterion validity, convergent validity and discriminative validity were used to evaluate the validity. Results: The 25-item TCSE-scale was found to have three subscales-Cognitive, Practical, and Affective domain-explaining 91.5% of the total variance. TCSE-scale also demonstrated a concurrent validity with the Cultural Competence Scale. Criterion-related validity was supported by known-group comparison. Reliability analysis showed an acceptable-to-high Cronbach's alpha-.88 in total, and subscales ranged from .76 to .87. The ICC was .90, indicating that the TCSE-scale has internal consistency and stability of reliability. Conclusion: This preliminary evaluation of the psychometric scale properties demonstrated an acceptable validity and reliability. The TCSE-scale is able to contribute to building up empirical and evidence based on data collection regarding the transcultural self-efficacy of clinical nurses. We suggest further testing of the applicability of TCSE-scale in different settings and community contexts.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method

  • Nabil M. Mansour;Mohamed E. Abdelshaheed;Ahmed H. El-Sabbagh;Ahmed M. Bahaa El-Din;Young Chul Kim;Jong-Woo Choi
    • Archives of Plastic Surgery
    • /
    • v.50 no.3
    • /
    • pp.254-263
    • /
    • 2023
  • Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations: 0.18 mm; mean angular variations: 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

Interim Relief in International Commercial Arbitration (국제상사중재(國際商事仲裁)에 있어서 중간보전조치(中間保全措置))

  • Lee, Kang-Bin
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.13
    • /
    • pp.131-149
    • /
    • 2000
  • In connection with international commercial arbitration the need to seek interim relief is generally recognized. Interim reliefs address the requirements of a party for immediate and temporary protection of rights or property pending a decision on the merits by the arbitral tribunal. The most common forms of interim relief are attachments and injunctions. If the arbitral tribunal has not yet been appointed, an application for interim relief must usually be addressed to the local courts at the place of commercial arbitration. If the arbitral tribunal has been appointed, the application for interim relief is first made to the arbitral tribunal. Interim relief by the arbitral tribunal is in the form of a direction to the parties. Since the arbitral tribunal has no enforcement power, it may be necessary to have a arbitral tribunal's direction confirmed by a local court which can enforce its order. The New York Convention does not provide for interim reliefs. The question is whether Article II(3) of the New York Convention that the court "shall, at the request of one of the parties, refer the parties to arbitration" denies jurisdiction to courts to grant interim reliefs in international commercial arbitration. Some cases have indicated that the U. S. court have no power to grant interim relief. Other cases have indicated that the U. S. courts do have the power to grant interim relief. It is unlikely that a U. S. court will order interim relief in relation to an commercial arbitration in a foreign country. Article 26 of the UNCITRAL Arbitration Rules provides with respect to interim measures of protection. Section 1 of Article 26 of UNCITRAL Arbitration Rules provides that the arbitral tribunal may take any interim measures it deems necessary in respect of the subject matter of the dispute, including measures for the conservation of the goods forming the subject matter in dispute. This article gives the arbitral tribunal the broadest authority, not limited to safeguarding property. Article 17 of the UNCITRAL Model Law on International Commercial Arbitration provides that the arbitral tribunal may order any party to take such interim measure of protection as the arbitral tribunal may consider necessary in respect of the subject matter of the dispute. It may be noted that the article does not deal with enforcement of such measures. The International Chamber of Commerce Rules of Conciliation and Arbitration do not expressly empower the arbitral tribunal to grant interim reliefs. However, Article 8.5 of the ICC Rules of Conciliation and Arbitration provides that the parties shall be at liberty to apply to any competent judicial authority for interim measures. In conclusion, the power of the arbitral tribunal to provide interim reliefs is generally recognized in the arbitration rules of arbitral institutions. However, the arbitral tribunal's authority is limited by its lack of enforcement mechanisms. It is generally recognized that the local courts have power to grant interim reliefs in aid of an commercial arbitration. However, local courts are reluctant to grant interim reliefs if that decision requires an adjudication of issues within the special competence of the arbitral tribunal.

  • PDF

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.