• 제목/요약/키워드: IBASPM

검색결과 2건 처리시간 0.015초

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

  • Kim, Ju Ho;Choi, Dae Seob;Kim, Seong-hu;Shin, Hwa Seon;Seo, Hyemin;Choi, Ho Cheol;Son, Seungnam;Tae, Woo Suk;Kim, Sam Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: To investigate the value of image post-processing software (FreeSurfer, IBASPM [individual brain atlases using statistical parametric mapping software]) and inversion time (TI) in volumetric analyses of the hippocampus and to identify differences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) with a slice thickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumes were measured using FreeSurfer, IBASPM and manual tracing. Statistical differences were examined using correlation analyses accounting for spatial interpretations percent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximum percent volume difference at TI = 800 ms ($77.1{\pm}2.9%$) and TI = 1100 ms ($13.1{\pm}2.1%$), respectively. The respective values for IBASPM were TI = 1100 ms ($55.3{\pm}9.1%$) and TI = 800 ms ($43.1{\pm}10.7%$). FreeSurfer presented a higher correlation than IBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition and analysis image is accurate and preferable.

IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰 (A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM)

  • 김주호;이주원;김성후
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.981-984
    • /
    • 2014
  • IBASPM(Individual Brain Atlases using Statistical Parametric Mapping Software)를 이용하여 해마의 체적 측정시, Atlas의 종류(Atlas69, Atlas71, Atlas84, Atlas116)에 따른 체적의 변화를 평가하기 위해 20대 정상 성인 10명(남5/여5, $23.3{\pm}2.66$)으로부터 뇌 영상을 획득하였다. 1.5T MRI system(Siemens, Avanto, Erlangen, Germany)의 머리 격자코일(Head matrix coil)을 사용하여 3차원 경사에코 펄스 열(3-D gradient echo pulse sequence)인 MPRAGE(Magnetization Prepared Rapid Acquisition Gradient Echo)영상을 획득하였다. Atlas의 종류에 따라 획득된 해마의 체적을 이용하여 대응표본 t 검정(Paired t-test)을 수행한 결과, 좌측 해마옆이랑(parahippocampal gyrus - left) Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729), 우측 해마형성체(hippocampal formation - right) Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219)는 유의한 차이가 없었으며, 이를 제외한 부분에서 유의한 차이가 있었다(p=0.000). 그러고 Atlas84와 Atlas116을 이용한 해마의 체적은 모두 동일한 값을 나타내어 유의한 차이가 없었다(p=0.000). Atlas영상과 원본 영상의 overlay를 이용한 영상분석에서는 Atlas71에서만 해마의 부위가 잘 못 정합되는 것을 발견할 수 있었다. 본 연구에 사용된 Atlas의 경우에는 서양인을 바탕으로 개발되었기 때문에 동양인의 뇌와는 차이가 있으며, 정확성 높은 체적의 측정을 위해서는 상황에 맞는 Atlas의 개발이 필요할 것으로 사료된다.

  • PDF