• Title/Summary/Keyword: IBASPM

Search Result 2, Processing Time 0.018 seconds

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

  • Kim, Ju Ho;Choi, Dae Seob;Kim, Seong-hu;Shin, Hwa Seon;Seo, Hyemin;Choi, Ho Cheol;Son, Seungnam;Tae, Woo Suk;Kim, Sam Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: To investigate the value of image post-processing software (FreeSurfer, IBASPM [individual brain atlases using statistical parametric mapping software]) and inversion time (TI) in volumetric analyses of the hippocampus and to identify differences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) with a slice thickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumes were measured using FreeSurfer, IBASPM and manual tracing. Statistical differences were examined using correlation analyses accounting for spatial interpretations percent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximum percent volume difference at TI = 800 ms ($77.1{\pm}2.9%$) and TI = 1100 ms ($13.1{\pm}2.1%$), respectively. The respective values for IBASPM were TI = 1100 ms ($55.3{\pm}9.1%$) and TI = 800 ms ($43.1{\pm}10.7%$). FreeSurfer presented a higher correlation than IBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition and analysis image is accurate and preferable.

A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM (IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰)

  • Kim, Ju-ho;Lee, Ju-won;Kim, Seong-hu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.981-984
    • /
    • 2014
  • Volumetric measurement of hippocampus using IBASPM, the 20's normal adults 10 people's brain images were acquired in order to assess the changes according to the type of the Atlas. Images was obtained using MPRAGE of a 3-D gradient echo pulse sequence on Head matrix coil of 1.5T MRI system. The results of Paired t-test using obtained volume of hippocampus depending on the type of the Atlas, Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729) in the left hippocampus and Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219) in right hippocampal formation were no significant differences but in the area except this, there was significant difference(p=0.000). The volume of the hippocampus using Atlas84 and Atlas116, represented the same value and there was no significant difference. In the image analysis using the overlay of atlas image and original image, Atlas71 could be found that the area of hippocampus did mismatch. In the case of atlas used in this study, because it has been developed by the westerners, there are differences between brain of asian. It would be needed to development of new Atlas for high accuracy measurement of the volume of hippocampus.

  • PDF