Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.
The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.
In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.
Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.
Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio-filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.
Sohn, Jong-Ryeul;Kim, Jo-Chun;Kim, Min-Young;Son, Youn-Suk;Sunwoo, Young
Asian Journal of Atmospheric Environment
/
제2권1호
/
pp.54-59
/
2008
The most pivotal approach to improve subway indoor air quality (IAQ) is to examine the emission sources and particulate behavior. Therefore, the main objective of this study is to investigate the particulate behavior in the subway. In order to examine IAQ in the subway, a sampling and measurement campaign was carried out for 35 sites during the summer and winter seasons from May, 2005 to February, 2006. In case of 24 hour measurement, the mean concentrations ($PM_{10}$-24 hr) of platform and waiting room were $156.18{\pm}53.79{\mu}g/m^3$ and $111.00{\pm}53.31{\mu}g/ m^3$. Besides, as a result of 20 hour measurement, the mean concentrations ($PM_{10}$-20 hr) of platform and waiting room were $146.09{\pm}53.71{\mu}g/m^3$ and $99.08{\pm}42.77{\mu}g/m^3$, respectively. In general, $PM_{10}$-24 hr was higher than $PM_{10}$-20 hr, and both PM concentrations showed a high correlation coefficient (r=0.803). It was found that the $PM_{2.5}$ concentration ($l09.56{\pm}28.24{\mu}g/m^3$) in winter was higher than that ($83.66{\pm}57.82{\mu}g/m^3$) in summer.
현대사회는 많은 교통수단이 이용되고 있으며, 그 중 수도권 도시철도는 하루 평균 721만명이 사용하는 중요한 교통수단이다. 실내공기질에 대한 관심과 PSD의 설치로 인해 터널내공기질 문제에서 객실내 공기질로 이동하고 있다. 하지만 현재 객실내 공기질 향상을 위한 장치는 전무한 상태이며 기존 에어필터 기술 적용시 설치비용과 유지보수가 문제점으로 지적되고 있다. 연구의 최종목표는 미세먼지와 이산화탄소를 효과적으로 저감시킬수 있는 독립형 청정장치를 개발하는 것이고, 본 연구에서는 미세먼지 저감기능을 수행하는 롤필터 집진 장치개발을 목적으로 한다. 객실내 롤필터 집진장치를 설치할 수 있는 공간에 대해 조사하고, 이에 따른 도시철도 객실 먼지저감에 효과적인 시스템 구조를 제시하였으며, 적정 풍량을 산정하다. 유동해석과 먼지저감효율에 대한 수치해석적 연구를 통해 최적운영 조건을 분석하였다. 그리고 롤필터에 적용가능한 필터재질에 대하여 차압특성과 입자포집효율을 평가하여 객실 유닛에 가장 적합한 필터를 선정하였다.
The most principal approach to improve indoor air quality(IAQ) of subway was to examine the fine particulate(PM-10) from the emission sources. Therefore, this study was carried on the investigation the fine particulate for comparison with the removal efficiency of PM-10 in divided the PSD(Platform Screen Door) and Non-PSD subway station from July, 2007 to May 2008. In the monitoring results, the range of PM-10 concentration of Non-PSD station was $44.6{\sim}116.5{\mu}g/m^3$ and the range of PM-10 concentration of PSD station was $23.9{\sim}81.1{\mu}g/m^3$. And then the range of PM-2.5 concentration of Non-PSD station was $17.4-56.6{\mu}g/m^3$, and then the range of PM-2.5 concentration of PSD station was $17.9{\sim}34.4{\mu}g/m^3$. In comparison with the results of the PSD and Non-PSD subway station, we found that the PM-10 removal efficiency of PSD was 30-40%. In conclusion, the PSD will be applied the effective facilities of decreasing PM-10 in subway station in Korea.
Objectives: This study aimed to assess the environmental factors that affect particulate matters (PM10) and to compare with outdoor PM10 concentrations in an underground subway stations. Methods: The PM10 level was determined from May 2013 to September 2013 in the Seoul subway stations in four lines. PM mini-vol portable sampler sampler was used to collect PM10 for 6 hrs. Arithmetic means of PM10 concentrations with standard deviation (SD) were calculated. Paired t-test was used to compare the differences between indoor PM10 and outdoor PM10 concentrations with correlation analysis which was used to identify the association between indoor PM10 concentrations and environmental factors. Results: There were no different PM10 concentrations significantly between line 1, 2, 3 and 4 in an underground subway stations. Passenger number was positively associated with PM10 concentration while construction year was negatively associated with PM10 concentrations. Indoor PM10 concentrations were significantly higher than those in outdoor PM10 concentrations. PM10 concentrations were higher in the stations which were constructed before 1990s rather than the stations constructed after 1990s. Conclusion: PM10 levels in the underground subway stations varied greatly depending on the construction year. Therefore, it might need to be more careful management to the stations which constructed in before 1990s.
본 연구에서는 비분산적외선(NDIR) 방식의 CO$_2$센서를 이용하여 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템을 구현하고 실제 지하철 승강장에 설치한 후 성능평가를 수행하였다. 서울 지하철은 하루 650만 명이 이용하는 대표적인 대중교통 수단이다. 따라서 승객뿐만 아니라 지하철 역사의 지하 공간에서 근무하는 많은 근로자들의 건강에 대한 관심이 높아짐에 따라 지하철 역사의 공기질 모니터링에 대한 요구가 매우 높아졌다. 현재 이런 요구를 충족하기 위해 환경부와 지하철 운영기관 측에서는 지하철역 공기질 모니터링 시스템을 일부 설치 운영 중이다. 그러나 고가의 수입 센서 이용으로 장비의 규모가 크고 설치 및 상시 운영에 따른 유지보수 비용이 큰 한계점이 있다. 따라서 본 연구에서는 저비용으로 CO$_2$ 농도를 상대적으로 정밀하게 측정할 수 있는 상용화된 CO$_2$ 센서에 대해 이론적으로 분석하고 신뢰성 검증 테스트를 수행하였다. 또한 무선 공기질 측정 센서 노드 및 게이트웨이 시스템을 개발하여 지하철 승강장의 실시간 공기질 데이터를 주기적으로 수집할 수 있고, 효율적으로 모니터링 할 수 있는 웹서버를 구축하였다. 본 연구 결과는 향후 지하 공간 공기질 관리 시스템의 확산 설치를 위하여 기초 연구 자료로 활용될 것이다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.