• Title/Summary/Keyword: I-TEQ

Search Result 26, Processing Time 0.022 seconds

Characteristics of Contamination for Persistent Organic Pollutants in Soil by Land Use (토지 이용형태별 잔류성유기오염물질의 오염특성)

  • Lee, Min-Jin;Kim, Kyoung-Soo;Yoon, Jeong-Ki;Kim, Tae-Seung;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.208-216
    • /
    • 2009
  • This study was performed to investigate levels of POPs in soil by land use and identify congener profiles of PCBs, PCDD/Fs in soil in Korea. Heptachlor, Aldrin, Endrin, Mirex, Toxaphene were not found in all areas. The concentrations of Diedrin, Chlordane, ${\Sigma}$DDT, HCB in soil samples were in ranged from N.D. to 12.08 ${\mu}g$/kg, from N.D. to 16.08 ${\mu}g$/kg, from N.D. to 38.19 ${\mu}g$/kg and from N.D. to 1.32 ${\mu}g$/kg. In case of PCBs, concentration were in ranged from N.D. to 172.12 ${\mu}g$/kg, and PCBs contaminated area was higher than other areas. The concentrations of PCDD/Fs were in ranged from 0 to 6.68 pg I-TEQ/g. In addition, the ${\Sigma}$PCDFs concentration in the industry area soil was higher than ${\Sigma}$PCDDs.

The Caracteristics and concentration of PCDDs/ PCDFs in scatterable dust on the edges of highway (자동차 전용 도로변 비산 가능한 먼지 중 PCDDs/ PCDFs의 농도 특성)

  • 최용석;엄정훈;윤중섭;김민영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.249-250
    • /
    • 2003
  • 다이옥신류의 주된 생성원인은 쓰레기 소각장에서의 배출가스에 기인한다고 알려져 있다.$^{1,3,4)}$ 그 밖에 농약제조, pulp 제조과정에서 부산물로 생성되기도 하고, 자동차배가스도 다이옥신의 생성원인 중에 하나이다. Miyabara$^{5)}$ 등은 일본내 자동차 배출가스 입자중 다이옥신류의 농도는 4.2-242 pg I-TEQ/g이였으며, 일본에서 배출하는 다이옥신류의 약 0.3%에 달한다고 추정하였다. 도로변 퇴적물 둥에서의 다이옥신 농도는 자동차 배출가스 등으로부터 직ㆍ간접으로 많은 영향을 받고 있으며, 이들이 비산할 경우 운전자의 호흡기를 통해 건강에 직접적으로 영향을 미칠 수 있다.$^{2)}$ (중략)

  • PDF

Content characteristics of persistent organic pollutants waste from paint, iron making and steel making process (국내 도료 및 제철·제강산업 발생 폐기물 중 잔류성 유기오염물질류의 함량 특성 -PCDD/DFs, PAHs, PCBs-)

  • Kim, Dong-Un;Kim, Woo-Il;Kang, Young-Yeul;Lee, Dong-Jin;Jeong, Seong-Kyeong;Cho, Yoon-A;Yeon, Jin-Mo;Shin, Sun-Kyoung;Oh, Gil-Jong
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.395-400
    • /
    • 2011
  • This study has been carried out in order to effectively manage three groups of unregulated hazardous organic substances (PCDD/DFs, PAHs, PCBs) in South Korea. The investigated substances have been analyzed according to the test methods for hazardous substances in specified wastes provided by the National Institute of Environmental Research, Korea. Total contents of the organic compounds have been determined for hazardous wastes from three major industrial categories (paint, iron removal, steelmaking), such as waste organic solvent, waste paint or dust. By investigating the waste samples for 7 PAHs using GC/MSD, Naphthalene has been detected (N.D~1631.33 mg/kg). The highest Naphthalene concentration, which exceeded the korean marine dumping waste standard, was found in waste organic solvents and waste paints. Although a content analysis of 7 PCB isomers has been conducted, none of these compounds was detected. The analysis of PCDD/DFs has revealed that all samples meet the criterion for low POP content defined in the technical guidelines developed under the Basel Convention. The PCDD/DFs content in dust samples deriving from 10 manufacturing processes (billet, bloom) was determined to be in the range of N.D~5.66 ng I-TEQ/g waste.

Frequency-Domain Equalizer Using 2-Dimensional LMS Algorithm for DWMT Based VDSL Transceiver (DWMT 기반 VDSL 송수신기를 위한 2차원 LMS 방식의 주파수 영역 등화기 구현)

  • 박태윤;최재호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.629-634
    • /
    • 2000
  • In this paper, we describe the structure of the DWMT (discrete wavelet multitone) transceiver for VDSL system. The DWMT transceiver consists of the transmultiplexer using cosine modulation filter bank (CMFB), time domain equalizer (TEQ) and frequency domain equalizer (FEQ) minimizing the effects of the transmission channel. For FEQ, we have expanded the conventional l-D linear transversal equalizer into 2-dimensions, i.e. time and subchannel axes and we have implemented it using the 2-dimensional LMS methods. In order to qualify the performance of FEQ, we have applied it to the DWMT based VDSL transceiver and the equalizer's performance is verified by simulation using the VDSL line test model specified by the ANSI T1E1.4 requirements.

  • PDF

Analysis of all PCB Congeners in Air Samples by HRGC/HRMS (대기 시료 중 PCBs 전 이성체 분석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.309-319
    • /
    • 2003
  • This study was performed to describe analysis method of 209 PCB congeners in ambient air samples. The samples were collected by high volume air sampler in Chonju city. Extracted samples were cleaned by silicagel cleanup modified with sulfuric acid and activated carbon cleanup processing. The cleaned samples were analyzed by high resolution gas chromatography and high resolution mass spectrometry (HRGC/HRMS) with DB-5 column (60 m, 0.25 mm i.d., 0.25 m film thickness) to analyze the 209 kinds of PCB congeners. PCBs levels of air samples were detected to the range between 0.003 and $0.163pg-TEQ/m^3$. The PCBs congener of 162 kinds were detected in samples analysed using DB-5 column and 37 kinds peaks were overlapped with congeners more than one. It is difficult to isolate PCB 118/106 and PCB 105/127 in coplanar PCB, so it is likely to overestimate the concentration.. The distribution of coplanar-PCB congeners in origin source samples (Kanechlor and exhaust gas from incinerator) was compared with that in air samples, and PCB 81, PCB 77, PCB 126, and PCB 169 were higher in incinerator samples.

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF