Fault Current Limiting and Hysteresys Characteristics of a SFCL using Magnetic Coupling of Two Coils on the Iron Core with an Air-Gap (공극이 도입된 철심에 코일의 자기결합을 이용한 초전도한류기의 고장전류 제한 및 히스테리시스 특성)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • In this paper, the fault current limiting and the hysteresys characteristics of a superconducting fault current limiter (SFCL) using magnetic coupling of two coils on the iron core with an air-gap were analyzed. The introduction of the air-gap in the SFCL with magnetically coupled two coils can suppress the saturation of the iron-core and, on the other hand, make the limiting impedance of the SFCL decreased, which results from the increase of the exciting current. To analyze the effect of the aig-gap on the fault current limiting characteristics of the SFCL, the hysteresys curves of the iron core comprising the SFCL were derived from the short-circuit experiment and the variation in the voltage-current trace of the SFCL during the fault period was analyzed. Through the comparison with the current limiting characteristics of the SFCL without air-gap, the air-gap could be confirmed to contribute to the suppression of the iron core's saturation through the increase of the SFCL's burden from the short-circuit current.

A study of an Active Stick Controlling System with Friction Observer (Active Stick 제어기 개발에 관한 연구)

  • Kim, Myung-Yul;Nam, Yoon-su
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.207-214
    • /
    • 2004
  • An active stick which supplies force feedback to the operator is developed in this study. A mathematical model of the active stick is derived, and compared with the experimental result. It turns out that the frictional torque due to the mechanical contacts of several parts of the stick is one of the major barriers to achieve high precision operation of the stick. The frictional effect of the stick is cancelled out by using a friction observer. The efficacy of the friction observer is verified through the numerical simulation. Because of the observer dynamics, there are some limitations in exact recovering the static friction and Stribeck effect. However, the friction observer follows the real friction on the average. It's anticipated that the application of the friction observer to the closed loop control of the active stick improves the performance of the displacement versus force characteristics, which will be proved experimentally in the further study.

  • PDF

Development of Piezo-Eloectric Micro-Depth Control System (압전소자에 의한 미세이송시스템의 개발에 관한 연구)

  • 김동식
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.03a
    • /
    • pp.40-62
    • /
    • 1995
  • A micro positioning system using piezoelectric actuators have very wide application region such as ultra-precision machine tool optical device measurement system. In order to keep a high precision displacement resolution it to useful to take a position sensor and feedback of the error. From the practical point of view high-resolution displacement sensor systems are very expensive and it is difficult to make such a sensitive sensor work properly in a poor operational environment of industry. In this study a piezo-electric micro-depth control system which does not require position sensor but piezoelectric voltage feedback has been developed. It is driven by hysteresis-considering reference input voltage calculated in advance and actuator/sensor characteristics of piezoelectric materials. From the result of experiments a fast and stable response of micro-depth control system has been achieved and an efficient technique to control the piezoelectric actuator suggested.