• Title/Summary/Keyword: Hygrothermal environment

Search Result 44, Processing Time 0.02 seconds

Collapse Characteristics of CFRP Hat Shaped Members under the Hygrothermal Environment According to Stacking Angle (열습환경 하에서의 적층각도 변화에 따른 CFRP 모자형 단면부재의 압궤특성)

  • Yang, Yong-Jun;Yang, In-Young;Sim, Jae-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.507-513
    • /
    • 2009
  • It is important to satisfy the requirements and standards for the protections of passengers in a car accident. There are lots of studies on the crushing energy absorption of structure members in automobiles. We have investigated collapse characteristics and moisture absorption movements of CFRP(Carbon Fiber Reinforced Plastics) hat shaped sectional members when CFRP laminates are under the hygrothermal environment. The absorbed energy, mean collapse load and deformation mode were analyzed for side members which absorbed most of the collision energy. Therefore we have made a static collapse experiment to research into the difference of absorbed energy and deformation mode between moisture absorbed specimen and non-moisture absorbed specimen.

  • PDF

Effect of hygrothermal aging on GFRP composites in marine environment

  • Garg, Mohit;Sharma, Shruti;Sharma, Sandeep;Mehta, Rajeev
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.93-104
    • /
    • 2017
  • In the present work, the effect of hygrothermal aging on the glass fibre and epoxy matrix interface has been investigated by destructive and non-destructive techniques. The glass fiber reinforced polymer (GFRP) composite laminates were prepared using Vacuum Assisted Resin Infusion Molding (VARIM) technique and the specimens were immersed in simulated seawater, followed by quantitative measurement. Besides this, the tensile tests of GFRP specimens revealed a general decrease in the properties with increasing aging time. Also, exposed specimens were characterized by a non-destructive ultrasonic guided Lamb wave propagation technique. The experimental results demonstrate a correlation between the drop in ultrasonic voltage amplitude and fall in tensile strength with increasing time of immersion. Hence, the comparison of the transmitted guided wave signal of healthy vis-a-vis specimens subjected to different extents of hygrothermal aging facilitated performance evaluation of GFRP composites.

Comparison of Hygrothermal Performance between Wood and Concrete Wall Structures using Simulation Program

  • Yu, Seulgi;Chang, Seong Jin;Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.283-293
    • /
    • 2016
  • Owing to an increase in the air tightness of recent buildings, the natural ventilation rate was significantly lowered and the removal of accumulated moisture became difficult in these buildings. The hygrothermal performance of these buildings should be carefully considered to provide comfortable indoor environment by removing the moisture condensation risk and the mold growth potential. In this study, hygrothermal performance of two selected wall structures was investigated based on WUFI simulation program. The results displayed that the indoor temperature had impact on the moisture accumulation in the insulation layer for both modeled walls, showing that lower indoor temperature resulted in higher moisture accumulation, especially in the wood frame structure. Also, the yearly moisture accumulation profile exhibited a downward shift throughout the year by adding a vapour retarder with a lower sd-value. In addition, both of the two walls have condensation risk in winter, due to low temperature level. The wood frame structure has a bigger fluctuation and higher condensation risk than the concrete structure.

Influences of hygrothermal environment and fiber orientation on shear correction factor in orthotropic composite beams

  • Soumia Benguediab;Fatima Zohra Kettaf;Mohammed Sehoul;Fouad Bourada;Abdelouahed Tounsi;Mohamed Benguediab
    • Coupled systems mechanics
    • /
    • v.12 no.2
    • /
    • pp.151-165
    • /
    • 2023
  • In this study, a simple method for the determination of the shear correction factor for composites beam with a rectangular cross section is presented. The plane stress elasticity assumption is used after simplifications of the expression of the stress distribution in the beam. The different fiber orientation angle and volume fraction are considered in this work. The studied structure is subjected to various loading type (thermal and hygrothermal). The numerical results obtained show that there is a dependence of the shear coefficient on the orientation of the fibers. The evolution of the shear correction factors depends not only on the orientation of the fibers and also on the volume fraction and the environment. the advantage of this developed formula of the shear correction factor is to obtain more precise results and to consider several parameters influencing this factor which are neglected if the latter is constant.

A Study on the Bearing Strength of Bolt Jointed Section for Composite Aircraft Radome Under Hygrothermal Environments (열습환경을 고려한 항공기용 레이돔 볼트 체결부의 베어링 강도에 관한 연구)

  • Kim, Ho Il;Ryu, Guh Yun;Kim, Joon;Kim, Kwang Min;Lee, Kyu Song;Park, Young Ju;Park, Byum Jun;Ryu, Hong Kyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.759-764
    • /
    • 2017
  • This research investigated the hygrothermal effect on the strength of bolt jointed section and moisture contents of composites exposed to hygrothermal environment for composite aircraft radome. The decrease in strength in the test environment is mainly attributed to the change in the material properties of the matrix due to temperature and moisture. The composite specimens were tested in three different environmental conditions: RTD(room temperature and dry), CTD(cold temperature and dry) and ETW(elevated temperature and wet). The failure mode of the bolt jointed composite specimens were studied using tests and finite element analysis. Finite element analysis reasonably predicted the failure load and mode of the joints. A reliability-based design was carried out for the bolt jointed composites of radome.

Hygrothermoelasticity in a porous cylinder under nonlinear coupling between heat and moisture

  • Ishihara, Masayuki;Yoshida, Taku;Ootao, Yoshihiro;Kameo, Yoshitaka
    • Structural Engineering and Mechanics
    • /
    • v.75 no.1
    • /
    • pp.59-69
    • /
    • 2020
  • The purpose of this study is to develop practical tools for the mechanical design of cylindrical porous media subjected to a broad gap in a hygrothermal environment. The planar axisymmetrical and transient hygrothermoelastic field in a porous hollow cylinder that is exposed to a broad gap of temperature and dissolved moisture content and is free from mechanical constraint on all surfaces is investigated considering the nonlinear coupling between heat and binary moisture and the diffusive properties of both phases of moisture. The system of hygrothermal governing equations is derived for the cylindrical case and solved to illustrate the distributions of hygrothermal-field quantities and the effect of diffusive properties on the distributions. The distribution of the resulting stress is theoretically analyzed based on the fundamental equations for hygrothermoelasticity. The safety hazard because of the analysis disregarding the nonlinear coupling underestimating the stress is illustrated. By comparing the cylinder with an infinitesimal curvature with the straight strip, the significance to consider the existence of curvature, even if it is infinitesimally small, is demonstrated qualitatively and quantitatively. Moreover, by investigating the bending moment, the necessities to consider an actual finite curvature and to perform the transient analysis are illustrated.

The Influence of Hygrothermal Effect to Residual Strength GFRP Composites (열습효과가 GFRP의 잔류강도에 미치는 영향)

  • 한길영;이동기;김이곤;김기성
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.57-62
    • /
    • 1995
  • The hygrothermal effect on three different types of Glass/Polypropylene was investigated under the environment of 4$0^{\circ}C$ distilled water. The residual strength of Glass/Polypropylene with randomly oriented and fiber content of 4-wt%(R40) was found stable under the moisture content of 0.2%. In this case, the maximum moisture content was 0.53%. On the other hand, Glass/Polypropylene with unidirection and 42wt%(U42) and 50st%(U50) fiber content, respectively, showed the residual strength less stable than R40. However, the maximam moisture contents were 0.52% and 0.45% respectively.

  • PDF

Impact Damages and Residual Strength of CFRP Laminates under the Hygrothermal Environment (고온.고습 환경에서 CFRP 적층재의 충격손상와 잔류강도)

  • Jeong, Jong-An;Yang, In-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.12
    • /
    • pp.3748-3758
    • /
    • 1996
  • This study is to investigate experimentally relationships between the impact energy and moisture absorption characteristies vs.the residual bending strength with the variation of stacking seqences. When Carbon-fiber reinforced plastics(CFRP) impact-induced laminates are subjected to the high temperatures and hygrothermal effects, it is found that what CFRP laminates are impacted by a steel ball (5 mm in diametar) ; thus, the generated delamination is observed by the ultrasonic microscope. And the residual bending strength is evaluated by a three-point bending test. Also, a thermostat is used in test with the unimpacted and impacted specimens for the moisture experimentaiton. The percision electro lever scles is used to measure the moisture content(1/10, 000g).

The Effect of Hygrothermal Aging on the Properties of Epoxy Resin

  • Wang, Youyuan;Liu, Yu;Xiao, Kun;Wang, Can;Zhang, Zhanxi
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.892-901
    • /
    • 2018
  • Because of excellent electrical properties, epoxy resin is widely used in packaging and casting power equipment. Moisture and temperature in the environment are inclined to seriously affect the insulation tolerance of epoxy resin. This work focuses on the aging characteristics of epoxy resin in hygrothermal environment. Scanning electron microscopy images show that there are micro-crack, micro-slit and holes inside aged samples. The moisture absorption process undergoes three equilibrium stages and it does not follow the Fick's second law. Observing the change of hydrogen bonds in the infrared spectra of the dried samples, it is found that chemically moisture absorption immerges when the physical moisture absorption entered the third equilibrium stage. By Debye equation to fit the imaginary part of the dielectric constant, it is concluded that the uniformity of water molecule has a great influence on the electrical conductivity loss. Furthermore, the polarization loss can be more easily affected by water molecules than small free molecules. After the aged samples being dried, their real and imaginary part of the dielectric constant descend, but their original electrical properties cannot completely restored. After chemical moisture absorption appears inside the material, the residual space charges increase significantly and the charge dissipation rate slow down obviously.

Strength Evaluation on CFRP Hat-shaped Sectional Members According to Changes in Temperature Under Hygrothermal Environment (온도 변화에 따른 열습 환경하에서의 CFRP 모자형 단면부재의 강도평가)

  • Yang, Yongjun;Kook, Hyun;Yang, Inyoung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.892-896
    • /
    • 2012
  • CFRP composites with light weight, high strength, and high elasticity by comparing with metal are widely used rather than previous steel plates. However, CFRP composite material has the weakness at hydrothermal and collapsed impact environment. Especially, moisture absorption into composite material can change molecule arrangement and chemical properties under hydrothermal environment. And static collapse experiment is the research in the differences of absorbed energy and deformation mode between moisture and non-moisture absorbed specimens. This study is compared and analyzed on the progress change of moisture absorption ratio after setting up the temperatures of 60 and 80 degrees C in order to comprehend how the change in the temperature influences on moisture absorption status inside CFRP composite materials.