• Title/Summary/Keyword: Hydrogen permeability

Search Result 141, Processing Time 0.028 seconds

A Study on the Palladium Alloy Membrane for Hydrogen Separation (수소 정제용 팔라듐 합금 분리막 연구)

  • Woo, Byung-Il;Kim, Dong-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.232-239
    • /
    • 2009
  • This study presented the effect of membrane thickness on hydrogen permeability. Microvoids on the surface of the membrane should not exist for the exact values of hydrogen permeability. Pd-Cu-Ni hydrogen alloy membranes were fabricated by Ni powder sintering, substrate plasma pretreatment, sputtering and Cu reflow process. And this leaded to void-free surface and dense film of Pd-Cu-Ni hydrogen alloy membrane. Hydrogen permeation test showed that hydrogen permeability increased from 2.7 to $15.2ml/cm^2{\cdot}min{\cdot}atm^{0.5}$ as membrane thickness decreased from 12 to $4{\mu}m$. This represented the similar trend as a hydrogen permeability of pure palladium membrane based on solution-diffusion mechanism.

Composite TiN-Al2O3 Syntheses and Hydrogen Permeability Characteristics Evaluation (복합 TiN-Al2O3 합성과 수소투과도 특성 평가)

  • CHO, KYOUNG-WON;LEE, YOUNG-HWAN;HAN, JEONG-HEUM;YU, JE-SEON;HONG, TAE-WHAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.2
    • /
    • pp.177-183
    • /
    • 2020
  • To utilize hydrogen energy, high-yield, high-purity hydrogen needs to be produced; therefore, hydrogen separation membrane studies are being conducted. The membrane reactor that fabricates hydrogen needs to have high hydrogen permeability, selective permeability, heatresistant and a stable mechanical membrane. Dense membranes of Pd and Pd alloys are usually used, but these have drawbacks associated with high cost and durability. Therefore, many researchers have studied replacing Pd and Pd alloys. Dense TiN membrane is highly selective and can separate high-purity hydrogen. The porous alumina has a high permeation rate but low selectivity; therefore, separating high-purity hydrogen is difficult. To overcome this drawback, the two materials are combined as composite reclamations to produce a separation membrane with a high penetration rate and high selectivity. Accordingly, TiN-alumina was manufactured using a high-energy ball mill. The TiN-alumina membrane was characterized by X-ray diffraction analysis, scanning electron microscopy, and energy dispersive spectroscopy. The hydrogen permeability of the TiN-alumina membrane was estimated by a Sievert-type hydrogen permeation membrane apparatus. Due to the change in the diffusion mechanism, the transmittance value was lower than that of the general TiN ceramic separator.

Comparison of Measurement Method of Hydrogen Permeability in Proton Exchange Membrane Fuel Cell (고분자전해질연료전지에서 수소투과도 측정법의 비교)

  • Oh, So-Hydong;Yun, Jeawon;Lee, Daewoong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.507-511
    • /
    • 2019
  • Hydrogen permeability is widely used to evaluate the polymer membrane durability of polymer electrolyte fuel cells (PEMFC). Linear sweep voltammetry (LSV) is mainly used to measure hydrogen permeability easily. There are many differences in LSV measurement method among researchers, and it is often difficult to compare the results. Therefore, in this study, we tried to confirm the accuracy by comparing the hydrogen permeability of LSV method and gas chromatograph which is difficult to measure but accurate value. The LSV method used the DOE and NEDO methods. When the hydrogen permeability was measured by varying the temperature and the relative humidity, the DOE LSV method showed an accuracy of less than 5% in the error range compared with the GC method. In the NEDO LSV method, the error was reduced when the hydrogen permeation current density was determined at the current value of 0.3 V as the DOE method.

Hydrogen Permeance of Ce1-xYxO2-δ Membranes According to Yttrium Content

  • Song, Da-Heoi;Jung, Mie-Won
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.451-453
    • /
    • 2013
  • Porous ceramic membranes consisting of $Ce_{1-x}Y_xO_{2-{\delta}}$ were developed for hydrogen permeation tests. Various amounts (x = 0, 0.05, 0.1, 0.2) of yttrium were doped to ceria to study the effect of yttrium doping on ceria membranes on various properties, including hydrogen permeability. $Ce_{1-x}Y_xO_{2-{\delta}}$ powder was synthesized by the sol-gel method. These membranes were fabricated by pressing and sintering at $1300^{\circ}C$ for 6 h. As the amount of yttrium increased, the grain size of the membrane decreased. Hydrogen permeability was improved as the yttrium content increased. Selective permeability of hydrogen compared to CO is explained by electric conductivity. As the temperature rose, both the hydrogen perm-selectivity and electric conductivity on $Ce_{0.8}Y_{0.2}O_{1.9}$ improved.

The Effect of Membrane Thickness on Durability and Performance of Proton Exchange Membrane Fuel Cell (고분자 전해질 연료전지의 전해질 막 두께가 내구성과 성능에 미치는 영향)

  • Hwang, Byungchan;Lee, Hyeri;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.473-477
    • /
    • 2017
  • The polymer membrane of proton exchange membrane fuel cell (PEMFC) has a great influence on PEMFC performance and durability. In this study, hydrogen permeability, fluorine emission rate (FER), lifetime, and performance of Nafion membranes with different thicknesses were measured to investigate the effect of thickness of polymer membrane on performance and durability. The relationship between membrane thickness and lifetime was obtained from the relationships between hydrogen permeability and membrane thickness, hydrogen permeability and FER, FER and lifetime. As the membrane became thicker, the hydrogen permeability and FER decreased and the lifetime increased. On the other hand, the performance decreased with increasing membrane resistance. The membrane thickness range satisfying both performance and durability was 25 to $28{\mu}m$.

Measurement of Hydrogen Crossover by Gas Chromatograph in PEMFC (고분자전해질 연료전지에서 기체 크로마토그래프에 의한 수소투과도 측정)

  • Jeong, Jaejin;Jeong, Jaehyeun;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2014
  • Until a recent day, degradation of PEMFC MEA(membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. Hydrogen permeability was used often to measure degradation of electrolyte membrane in PEMFC. In case of hydrogen permeability measured by LSV(Linear Sweep Voltammetry) method, the degradation of electrode decrease the value of hydrogen crossover current due to LSV methode's dependence on electrode active area. In this study hydrogen permeability was measured by gas chromatograph(GC) when membrane and electrode degraded at the same time. It was showed that degradation of electrode did not affect the hydrogen permeability measured by GC because of GC methode's independence on electrode active area.

Evaluation of at-home bleaching protocol with application on different surfaces: bleaching efficacy and hydrogen peroxide permeability

  • Heloisa Forville;Michael Willian Favoreto;Michel Wendlinger;Roberta Micheten Dias;Christiane Philippini Ferreira Borges;Alessandra Reis;Alessandro D. Loguercio
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.33.1-33.12
    • /
    • 2023
  • Objectives: This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods: Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔEab] and CIEDE 2000 [ΔE00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (㎍/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results: All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔEab and ΔE00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions: The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.

Protection by Sunghyangchungisan against Hydrogen Peroxide-induced Increase in Endothelial Permeability (배양 혈관 내피세포에서 Hydrogen Peroxide에 의한 투과성 증가에 미치는 성향정기산의 효과)

  • 이동언;김영균;권정남
    • The Journal of Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.193-203
    • /
    • 2000
  • Objectives : Hindered barrier function of vascular endothelium has been implicated in the initiation and progression of degenerative vascular diseases such as atherosclerosis. In this study, the effect of Sunghyangchungisan(SHCS) as a protectant against oxidant-induced destruction of endothelial barrier function was assessed. Methods : Toward this end, endothelial cells derived from the human umbilical vein were cultured as monolayers on permeable membrane filters. Endothelial permeability was monitored by measuring transendothelial electrical resistance and movement of low density lipoprotein (LDL) across the endothelial monolayer. Results : Along with increased movement of LDL, $H_2O_2$-induced increase in endothelial permeability was paralleled by a decrease in transendotheliaI electrical resistance. The effect of $H_2O_2$ was mimicked by phorbol 12-myristate 13-acetate (PMA), a potent activator of proteinkinase C. Calphostin-C, a protein kinase C inhibitor, effectively blocked the increase in endothelial permeability induced by $H_2O_2$ or PMA, indicating that activation of protein kinase C is associated with the $H_2O_2-induced$ permeability change. SHCS effectively protected the endothelial monolayer against $H_2O_2-induced$ increase in permeability, whereas, it did not affect PMA-induced change. Forskolin, a potent activator of adenylyl cyclase, antagonized $H_2O_2$ to increase endothelial permeability. In addition, in ${H_2O_2}-treated$ cens, intracenular cAMP concentration was significantly decreased, indicating that impaired cAMP production as well as activation of proteinkinase C is a mechanism underlying ${H_2O_2}>-induced$$H_2O_2$ with regard to its effect on intracellular cAMP content. However, SHCS itself did not affect resting cAMP concentration in endothelial cells. Conclusions : These results suggest that SHCS might operate as an effective protectant against oxidant-induced destruction of endothelial barrier function. The mechanism does not appear to involve direct interaction with protein kinase C- or cAMP-associated signaling mechanism.

  • PDF

Effects of Nickel Supports on Hydrogen Permeability of Vanadium based Membrane (니켈 지지체를 이용한 바나듐기 분리막의 수소 투과특성)

  • Cho, Kyoungwon;Choi, Jaeha;Jung, Seok;Kim, Raymundk.I.;Hong, Taewhan;Ahn, Joongwoo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.3
    • /
    • pp.200-205
    • /
    • 2013
  • The separation of hydrogen depends on porosity, diffusivity and solubility in permeation membrane. Dense membrane is always showing a solution diffusion mechanism but porous membrane is not showing. Therefore, porous membrane has a good hydrogen flux due to pore is carried out transferred media. This mechanism is named as the Knudsen diffusion. Hydrogen molecules or hydrogen atoms are diffused along pore that is a mean free path. In this study, complex layer hydrogen permeation membrane was fabricated by hot press process. And then, it was evaluated and calculated to relationship between hydrogen permeability and membrane porosity.

Properties of Synthesized Al2O3-CuO-ZnO/Ni Composite for Hydrogen Membranes

  • Rim, Saetbyol;Jung, Miewon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.477-480
    • /
    • 2014
  • An $Al_2O_3$-CuO-ZnO (ACZ) precursor powder was synthesized by a facial sol-gel process using a nonionic surfactant span 80 as the chelating agent to improve the surface area and morphology. When creating a hydrogen membrane, several kinds of properties are required, such as easy dissociation of hydrogen molecules, fast hydrogen diffusion, high hydrogen solubility, and resistance to hydrogen embrittlement. ACZ-Ni composite membranes (cermet) were prepared with this precursor and pure Ni powder via the hot press sintering (HPS) method. The ACZ powder was characterized by XRD, BET, and FE-SEM. Hydrogen permeation experiments were performed by Sievert's type of hydrogen permeation membrane equipment. The hydrogen permeability of ACZ/Ni 10 wt% and ACZ/Ni 20 wt% was obtained as 7.2 and $10molm^{-2}s^{-1}$ at RT, respectively. These values of the corresponding membranes were slightly increased with increasing pressures.