• Title/Summary/Keyword: Hydrogen leakage

Search Result 199, Processing Time 0.023 seconds

The Effects of Deposition Temperature of Pt Top Electrodes on the Electrical Properties of PZT Thin Films (Pt 상부 전극 증착온도가 PZR 박막의 전지적 특성에 미치는 영향)

  • Lee, Kang-Woon;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1048-1054
    • /
    • 1998
  • The effects of deposition temperature of Pt top electrodes on the electrical properties of Pb(Zr,Ti))$O_3$, (PZT) thin film were investigated. When the Pt top electrodes were deposited at substrate temperatures of $200^{\circ}C$ or above,the ferroelectric properties of the PZT thin film under the Pt electrode were severely degraded. Whereas those of the PZT film where the Pt electrodes were not deposited were not degraded. Water vapors which remained in the vacuum chamber were dissociated into hydrogen atoms by the catalysis of Pt top electrode, and those hydrogen atoms diffused into the PZT film and produced oxygen vacancies at high substrate temperature, resulting in the degradation of the ferroelectric properties of the PZT film located under the Pt electrode. Since the water vapors could not be dissociated into hydrogen atoms without the catalysis of Pt. the degradation of the PZT film did not take place where the Pt electrode were not deposited. The degraded feroelectric properties could be recovered by rapid thermal annealing (RTA) treatment. On the other hand. leakage current characteristics were improved with increasing the deposition temperature of Pt top electrodes.

  • PDF

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Trap Generation during SILC and Soft Breakdown Phenomena in n-MOSFET having Thin Gate Oxide Film (박막 게이트 산화막을 갖는 n-MOSFET에서 SILC 및 Soft Breakdown 열화동안 나타나는 결함 생성)

  • 이재성
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.1-8
    • /
    • 2004
  • Experimental results are presented for gate oxide degradation, such as SILC and soft breakdown, and its effect on device parameters under negative and positive bias stress conditions using n-MOSFET's with 3 nm gate oxide. The degradation mechanisms are highly dependent on stress conditions. For negative gate voltage, both interface and oxide bulk traps are found to dominate the reliability of gate oxide. However, for positive gate voltage, the degradation becomes dominated mainly by interface trap. It was also found the trap generation in the gate oxide film is related to the breakage of Si-H bonds through the deuterium anneal and additional hydrogen anneal experiments. Statistical parameter variations as well as the “OFF” leakage current depend on both electron- and hole-trapping. Our results therefore show that Si or O bond breakage by tunneling electron and hole can be another origin of the investigated gate oxide degradation. This plausible physical explanation is based on both Anode-Hole Injection and Hydrogen-Released model.

A Study on the Impact Scope from Hazardous Chemicals Leakage in Jeju Area - Focused on hydrogen fluoride - (제주지역 유해화학물질 누출사고 시 영향범위에 관한 연구 - 불화수소 중심으로 -)

  • Lim, Chaehyun;Doh, Sang Hyeun;Kim, Changyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.495-502
    • /
    • 2018
  • In this study, the AERMOD air diffusing model was used to estimate the range of influence of Hazardous chemicals (hydrogen fluoride) in case of small accidents in Jeju area. The impact scope were in the order of Seogwipo Fire Station, Dongbu Fire Station, Jeju Fire Station, and Seobu Fire Station. Seasonal orders were summer, spring, autumn and winter. The correlation between the meteorological factors shows a strong positive correlation with the wind speed of 0.998 and has a negative correlation with the temperature of -0.463. Through the linear regression analysis, we could estimate the equation of Impact scope = 13.922WS (Wind Speed) - 5.195 and the reliability ($R^2$) was as high as 0.995.

The Effects of Post-annealing on Laser CVD SiON Films (Laser CVD SiON막의 막 형성 후 열처리 의존성)

  • Kim, C.D.;Kim, I.S.;Koh, J.H.;Lee, S.K.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.336-338
    • /
    • 1997
  • The anneal behavior of ArF excimer Laser CVD SiON films has been studied using FT-IR absorption spectroscopy. The anneal temperature range was $400{\sim}800^{\circ}C$ Abundant hydrogen effusion from thes layers was observed as anneal temperature increased. The coexistence of both Si-H am N-H bonds offers the possibility for cross linking am evidence for the occurrence of cross lingking was found in the IR spectrum. The electrical properties were also obtained that tire films have low leakage currents am good TZDB properties.

  • PDF

Electrical Instabilities of Mesoporous Silica Thin Films

  • Dung, Mai Xuan;Jeong, Hyun-Dam
    • Journal of Integrative Natural Science
    • /
    • v.3 no.4
    • /
    • pp.219-225
    • /
    • 2010
  • On the surface of mesoporous silica thin films (MSTF) which were fabricated by sol-gel approach there are existences of water and three different silanol types including chained, germinal and isolated silanol. Their amounts changes as a function of aging time of used sol solution, as confirmed by FT-IR. The adsorbed water generates ionic carriers such as H+ and OH- and passivates the Si dangling bonds at the interface of silicon wafer-MSTF. The ionic carriers can not only transport across the thickness of thin film to enhance the leakage current but also diffuse toward the silicon wafer-MSTF interface to depassivate Si dangling bonds. On the other hand, chained silanols or germinal silanols promote the moisture adsorption of MSTF and tend to form strongly hydrogen bonded systems with adsorbed water molecules resulting in very high dielectric constant. Isolated silanol, on the contrary, affects less on electrical properties of thin film.

Characteristics of Polysilicon Thin Film Transistor with LDD Structure (LDD 구조의 다결성 실리콘 박막 트랜지스터의 특성)

  • 황한욱;황성수;김용상
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.7
    • /
    • pp.522-526
    • /
    • 1998
  • We have fabricated a LDD structured polysilicon thin film transistor with low leakge current and the optimized LDD length has been obtained. The device performance is improved is improved by hydrogen passivation process. The on.off current ratio of poly0Si TFT s with $0.5{\mu}m$ and $1.0{\mu}m$ LDD length is much higher than that of conventional structured device due to the decrease of leakege current. The optimized LDD length may be $0.5{\mu}$ from the experimental data such as on/off current ratio, threshold voltage and hydrogenation effect.

  • PDF

Electrical Properties of Diamond-like Carbon Thin Film synthesized by PECVD (PECVD로 합성한 다이아몬드상 카본박막의 전기적 특성)

  • Choi, Won-Seok;Park, Mun-Gi;Hong, Byung-You
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.973-976
    • /
    • 2008
  • In addition to its similarity to genuine diamond film, diamond-like carbon (DLC) film has many advantages, including its wide band gap and variable refractive index. In this study, DLC films were prepared by the RF PECVD (Plasma Enhanced Chemical Vapor Deposition) method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas. We examined the effects of the RF power on the electrical properties of the DLC films. The films were deposited at several RF powers ranging from 50 to 175 W in steps of 25 W. The leakage current of DLC films increased at higher deposition RF power. And the resistivities of DLC films grown at 50 W and 175 W were $5\times10^{11}$ ${\Omega}cm$ and $2.68\times10^{10}$ ${\Omega}cm$, respectively.

THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS (무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향)

  • Choi, Seung-Ho;Ro, Byeng-Duck;Park, Sung-Ho;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

Estimation of the Relative Risk of the Elderly with Different Evacuation Velocity in a Toxic Gas Leakage Accident (독성물질 누출 시 대피 속도 차이에 따른 고령자의 상대적 위험도 산정)

  • Lee, H.T.;Kwak, J.;Park, J.;Ryu, J.;Lee, J.;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.13-21
    • /
    • 2019
  • Leakage accidents in businesses dealing with hazardous chemicals can have a great impact on the workers inside the workplace, as well as residents outside the workplace. In fact, there were cases where hazardous chemicals leaked from many businesses. As a result, the Chemicals Control Act(CCA) was enacted in 2015, the Ministry of Environment introduced an Off-site Risk Assessment(ORA). The purpose of the ORA is to secure safety from the installation of the design of the workplace facilities so that chemical accidents of hazardous chemical handling facilities do not cause human or physical damage outside the workplace. In general, the ORA qualitatively determines where a protected facility is within the scope of the accident scenario. However, elderly who belong to the sensitive group is more sensitive than the general group under the same chemical accident effect, and the extent of the damage is serious. According to data from the Korea National Statistic Office, the number of elderly people is expected to increase steadily. Therefore, a quantitative risk analysis considering the elderly is necessary as a result of a chemical accident. In this study, accident scenarios for 14 locations were set up to perform emergency evacuation due to toxic gas leakage of Cl2(Chlorine) and HF(Hydrogen Fluoride), and the effects of exposure were analyzed based on the evacuation velocity difference of age 20s and 60s. The ALOHA(Areal Locations of Hazardous Atmospheres) program was used to calculate the concentration for assessing the effects. The time of exposure to toxic gas was calculated based on the time it took for the evacuation to run from the start point to the desired point and a methodology was devised that could be applied to the risk calculation. As a result of the study, the relative risk of the elderly, the sensitive group, needs to be determined.