• Title/Summary/Keyword: Hydrogen ion concentration

Search Result 235, Processing Time 0.027 seconds

Stability of pipethanate hydrochloride in aqueous solution

  • Kim, Chonng-Kook;Cha, Hyun-Sook
    • Archives of Pharmacal Research
    • /
    • v.4 no.2
    • /
    • pp.109-115
    • /
    • 1981
  • In the present investigation, an attempt has been made to apply the methods of classical chemical kinetics to the hydrolytic reaction of pipethanate hydrochloride. By successively keeping all but one variable essentially constant, it has been possible to resolve the overall effect of the individual contributing factors. Since nearly all commercial pipethanate preparations are formulated with antacid, studies were made at several constant hydrogen ion concentration ranging pH 0.4 to 7.5. Rate measurement was also carried out in temperature ranging from $25^{\circ}C$ to $60^{\circ}C$. The hydrolysis of pipethanate is found to be of first order with respect to pipeethanate concentration over an experimental range of hydrogen ion concentration (pH 0407.5). The apparent activation energy(Ea) at pH 7.5 is 18.30 Kcal/mole and the frequency factor is $1.1408 {\times}10^{9}sec^{-1}$. The rate of the hydrolysis has a minimum at pH 2.5-3.5. In this region the half-life of pipethanate was about15.3 days at $60^{\circ}C$. The catalytic effect of water was found to be $K_{H_2O}$ = $3.16{\times}10^{-5}min^{-1}$ at $60^{\circ}C$. The catalytic constants of the hydroxyl ions and hydrogen ions at $60^{\circ}C$ were also found to be $K_{OH}$ = $4.5519{\times}10^{-5}min^{-1}$ and $K_{H}+$ = $1.1568{\times}10^{-2}min^{-1}$, respectively. This reaction appears to be primarily base catalyzed hydrolysis and pipethanate is relatively reluctant toward acid catalyzed hydrolysis. A positive primary salt effect was noted in the solution of phpethanate at pH 7.5 and at $60^{\circ}C$.

  • PDF

Improvement of reliability of an ISFET pH-meter by employing multiple sensors

  • Chang, Kee-Seok;Cho, Byung-Woog;Kim, Chang-Soo;Choi, Sang-Bok;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.131-136
    • /
    • 1997
  • The ISFET(ion sensitive field effect transistor), a semiconductor ion sensor, has many advantages over conventional ion sensors. Various single-sensor type ISFET pH-meters have been developed. However, they could not be applied in fields because their performances are directly affected by the sensor condition. With only one sensor, the system could be easily damaged from environmental factors, and reliability of it is decreased. Therefore, a 4-channel PH-meter system is proposed to improve the reliability of ISFET pH-meter. It has 4 ISFETS as ion sensor, and a software which contains a new calibration and measurement algorithm appropriate to the system. The reliability of the system was proved by measuring hydrogen ion concentration in the pH standard solutions and buffer solutions.

  • PDF

Reductive Leaching of $LiCoO_2$in a Sulfuric Acid Solution (황산용액서 $LiCoO_2$의 환원침출)

  • 이철경;김낙형
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.9-14
    • /
    • 2001
  • A sulfuric acid leaching of $LiCoO_2$as cathodic active materials of lithium ion secondary batteries was investigated in terms of reaction variables. In the absence of a reducing agent, the extraction of cobalt was less than 40% in 2 M sulfuric acid at $75^{\circ}C$ instead of that of lithium could be almost 100% in the same conditions. To improve the Co extraction, hydrogen peroxide was used as a reducing agent in the range 2~20 vol%. When over 10vo1% hydrogen peroxide was added, the extractions of both metals were improved to about 95%. It seems to be due to the reduction of Co(III) to Co(II) that can be readily dissolved. The extractions of Co and Li were increased with increasing $H_2$$SO_4$concentration and temperature, and amount of hydrogen peroxide and with decreasing of pulp density. The optimum leaching conditions were determined at $2 M H_2$$SO_4$concentration, $75^{\circ}C$ operating temperature, 100 g/L. initial pulp density, 20 vol% $H_2$$O_2$addition and 30 min.

  • PDF

Removal of Inorganic Odorous Compounds by Scrubbing Techniques using Silver Nano-particles (나노 은 입자 세정법을 이용한 무기 악취물질의 제거)

  • Shin, Seung-Kyu;Huyen, Tran;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.6
    • /
    • pp.674-681
    • /
    • 2008
  • Silver as a metal catalyst has been used to remove odorous compounds. In this study, silver particles in nano sizes ($5{\sim}30nm$) were prepared on the surface of $NaHCO_3$, the supporting material, using a sputtering method. The silver nano-particles were dispersed by dissolving $Ag-NaHCO_3$ into water, and the dispersed silver nano-particles in the aqueous phase was applied to remove inorganic odor compounds, $NH_3$ and ${H_2}O$, in a scrubbing reactor. Since ammonia has high solubility, it was removed from the gas phase even by spraying water in the scrubber. However, the concentration of nitrate (${NO_3}^-$) ion increased only in the silver nano-particle solution, implying that the silver nano-particles oxidized ammonia. Hydrogen sulfide in the gas phase was rapidly removed by the silver nano-particles, and the concentration of sulfate (${SO_4}^{2-}$) ion increased with time due to the oxidation reaction by silver. As a result, the silver nano-particles in the aqueous solution can be successfully applied to remove odorous compounds without adding additional energy sources and producing any harmful byproducts.

Characteristic of Lower Hydrogenated Oxide Films Deposited by the Higher Energy Assisting Deposition Systems Using the with Precursor Siloxane Species

  • Kim, J.;Yang, J.;Park, G.;Hur, G.;Lee, J.;Ban, W.;Jung, D.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.339.1-339.1
    • /
    • 2014
  • In this paper we studied the application of inter-poly dielectric as silicon dioxide-like film was deposited by the higher energy assisting deposition (HEAD) process the modified CCP process, which enables low temperature (LT) process and improving film density. In these experiments the relative hydrogen concentration of $SiO_2$-like films deposited on silicon substrate were analyzed by the secondary ion mass spectroscopy (SIMS) and it was shown that our lower hydrogenated oxide (LHO) film prepared by HEAD process with the precursor contained the siloxane species had lower hydrogen concentration, $8{\times}10{\cdot}^{22}cm{\cdot}^3$ than that of the commercial undoped silicon glass (USG) film ($1{\times}10{\cdot}^{21}cm{\cdot}^3$) prepared by the high density plasma-chemical vapor deposition (HDP-CVD). We consider that the LHO film deposited by HEAD process used as high performance material into Flash memory devices.

  • PDF

Variation of Hydrogen Peroxide Concentration during Fenton Reaction for Test the Membrane Durability of PEMFC (PEMFC 고분자막 내구 평가를 위한 Fenton 반응에서 과산화수소 농도 변화에 관한 연구)

  • Oh, Sohyung;Kim, Jeongjae;Lee, Daewoong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.315-319
    • /
    • 2018
  • Fenton reaction is widely used as a out of cell method for evaluating the membrane electrochemical durability of Proton Exchange Fuel Cell (PEMFC). In this study, we investigated the factors affecting the Fenton reaction. In order to estimate the degree of the reaction, it is necessary to analyze the radicals as a product in the Fenton reaction. However, since the radicals are difficult to analyze, the degree of the reaction was measured by analyzing the concentration of hydrogen peroxide. The activation energy was calculated from the rate of hydrogen peroxide change with temperature. The activation energy was 24.9 kJ/mol at 180 min. The Fenton reaction rate was affected by the iron ion concentration. At $80^{\circ}C$, 200 rpm, and $Fe^{2+}$ 80 ppm, the concentration of hydrogen peroxide was decreased more than 20% even for 1 hour, which shows that frequent solution replacement increases the membrane degradation rate.

Estimation of the Concentration of HF in the Atmosphere Using Plant Leaves Exposed to HF in the Site of the HF Spill (불산 누출 사고 시 불산에 노출된 식물잎을 이용한 대기 중 불화수소 농도 추정)

  • Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2016
  • The leaves of three plant species, such as soybean, raspberry, and kudzu, exposed to hydrogen fluoride was collected in an area surrounding an emission source where the release accident occurred. The ultrasonic-assisted extraction and analysis of fluoride by ion chromatography was carried out. The mean concentration of fluoride in the leaves of three plant species exposed to hydrogen fluoride was $5,409{\pm}1,198mg\;F/kg\;dry\;wt$ and $788{\pm}339mg\;F/kg\;dry\;wt$, respectively. The mean fluoride concentration in ambient air were estimated to be $2.36{\pm}0.65mg/m^3$ ($2.89{\pm}0.79ppm$) and $0.35{\pm}0.15mg/m^3$ ($0.43{\pm}0.19ppm$) in exposed and unexposed sites, respectively. It seems likely that the passive monitoring using plant leaves could identify with respect to plant risk by fluoride in atmosphere.

Effect of a Series Connection of a Bi-Electrolyte Hydrogen Sensor in a Leak Detector

  • Han, Hyeuk Jin;Park, Chong Ook;Hong, Youngkyu;Kim, Jong Suk;Yang, Jeong Woo;Kim, Yoon Seo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.6-9
    • /
    • 2015
  • Conventional leak detectors are widely based on helium gas sensors. However, the usage of hydrogen sensors in leak detectors has increased because of the high prices of helium leak detectors and the dearth in the supply of helium gas. In this study, a hydrogen leak detector was developed using solid-state hydrogen sensors. The hydrogen sensors are based on Park-Rapp probes with heterojunctions made by oxygen-ion conducting Yttria-stabilized zirconia and proton-conducting In-doped $CaZrO_3$. The hydrogen sensors were used for determining the potential difference between air and air balanced 5 ppm of $H_2$. Even though the Park-Rapp probe shows an excellent selectivity for hydrogen, the sensitivity of the sensor was low because of the low concentration of hydrogen, and the oxygen on the surface of the sensor. In order to increase the sensitivity of the sensor, the sensors were connected in series by Pt wires to increase the potential difference. The sensors were tested at temperatures ranging from $500-600^{\circ}C$.

Effects of Ion Specificity on the Expansion Behavior of Polymer Gel with Phenyl Ring (Phenyl 고리를 갖는 고분자 겔의 팽윤거동에 대한 이온 특성화 효과)

  • Ahn, Beom-Shu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.278-285
    • /
    • 2012
  • Effects of ion species on the expansion behavior of Poly(styrene sufonic acid)(PSSA) hydrogel were investigated in aqueous solution of selected anions, cations and hydrophobic ions. The deexpansion extent of Poly(stylene sulfonic acid) gel follow the sequence $SCN^-$<$Br^-$<$Cl^-$<$F^-$ in low concentration solutions due to the destabilization of anions to hydrogen bond between ${SO_3}^-$ and water. The deexpansion in cations followed the sequence of counterion interactions between ${SO_3}^-$ and cations. It was discussed the effects of ions on the hydrogen bonding through ${SO_3}^-$ and phenyl ring in salt solutions. Other interactions, such as the cation-${\pi}$ interaction, hydrophobic interaction, and dispersion force, contributed to the ion specific swelling of PSSA hydrogel.

Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate (Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극)

  • Kim, Hwan-Ki;Shin, Doo-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.271-279
    • /
    • 1987
  • A nitrate ion-selective PVC membrane electrode based on ammonia modified bakelite A-Ni$(NO_3)_2$ complex as ion exchanger was prepared. The electrode gave a linear response with a Nernstian slope of 60mV per decade within the concentration range $1{\sim}10^{-4}$ M $KNO_3$ but nonresponse to hydrogen ion and multivalent anions. The selectivity, response time and life time of the electrode were investigated and it was found that the electrode exhibited good selectivity for four univalent anions ($Cl^-,\;Br^-,\;I^-,\;{ClO_4}^-$). Analytical application to the determination of nitrate were also studied.

  • PDF