• 제목/요약/키워드: Hydrogen ambient

검색결과 165건 처리시간 0.026초

Reactive sputtering 법으로 증착된 AZO 박막의 전기적 및 구조적 특성 (Electrical and structural characteristics of AZO thin films deposited by reactive sputtering)

  • 허주희;이유림;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.33-38
    • /
    • 2009
  • We have investigated the effect of the ambient gases on the characteristics of AZO thin films for the OLED (organic light emitting diodes) devices. These AZO thin films are deposited by rf-magnetron sputtering under different ambient gases (Ar, Ar+$O_2$, and Ar+$H_2$) at 300. In order to investigate the influences of the oxygen and hydrogen, the flow rate of oxygen and hydrogen in argon mixing gas has been changed from 0.2sccm to 1sccm and from 0.5sccm to 5sccm, respectively. The AZO thin films were preferred oriented to (002) direction regardless of ambient gases. The electrical resistivity of AZO film increased with increasing flow rate of $O_2$ under Ar+$O_2$ while under Ar+$H_2$ atmosphere the electrical resistivity showed minimum value near 1sccm of $H_2$. All the films showed the average transmittance over 80% in the visible range. The OLED device was fabricated with different AZO substrates made by configuration of AZO/$\acute{a}$-NPD/DPVB/$Alq_3$/LiF/Al to elucidate the performance of AZO substrate.

  • PDF

열처리 분위기에 따른 $MgB_2$ 초전도의 특성 변화 ($MgB_2$ Superconducting Properties under Different Annealing Condition)

  • 정국채;김영국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.362-362
    • /
    • 2009
  • $MgB_2$ bulk samples were sintered at different ambient. In this work, high purity Ar gas was added with oxygen and hydrogen gas, which can be regarded as impurity in a sense, as a possible dopant in the $MgB_2$. It was found that oxygen in the sintering ambient leads to a decrease in the critical current density $J_c$ at self field and lower fields. However, we can obtained higher $J_c$ at higher fields. It was also noted that $MgB_2$ samples sintered with 5% hydrogen in Ar revealed the increased $J_c$ at all fields compared to those processed in pure Ar ambient. From the XRD and FESEM analysis, the impurity gas in Ar can refine the $MgB_2$ grain size and result in increased grain. boundary, which can act as a strong flux pinning sites in $MgB_2$ samples. Also discussed are the effects of sintering ambient on irreversibility field, $H_{irr}$ and the upper critical field, $H_{C2}$.

  • PDF

구미 불산 누출사고 지점 주변 식물의 불소화합물 농도 분포 및 공기 중 불화수소 농도 추정에 관한 연구 (Study on the Distribution of Fluorides in Plants and the Estimation of Ambient Concentration of Hydrogen Fluoride Around the Area of the Accidental Release of Hydrogen Fluoride in Gumi)

  • 구슬기;최인자;김원;선옥남;김신범;이윤근
    • 한국환경보건학회지
    • /
    • 제39권4호
    • /
    • pp.346-353
    • /
    • 2013
  • Objectives: The goal of this study is to identify the distribution of the foliar fluorine content of vegetation surrounding the area where hydrofluoric acid was accidently released in Gumi, Gyeongsangbuk-do on September 27, 2012. In addition, it also aims to estimate the concentration of hydrogen fluoride in the air on the day of the accident. Methods: Samples of plant leaves were collected on October 7, 2012 within 1 km from the site where the accident occurred. These samples were analyzed for soluble fluorine ion with an ion selective electrode. The ambient concentration of hydrogen fluoride was calculated using the fluoride content in the plant via the dose-rate equation (${\Delta}F$=KCT). Results: The arithmetic and geometric means of the concentrations were 2158.2 and 1183.7mg F $kg^{-1}$ for leaves and, 2.4 and 1.1 ppm HF for the air, respectively. The highest concentration of hydrogen fluoride in the air was 14.7 ppm, which is higher than the maximum concentration reported by the government (1 ppm) and the exposure limit (ceiling, 3 ppm). The concentrations of both fluorine and hydrogen fluoride decreased with increasing distance from the accident site and showed a significant decrease outside of a 500m radius from the site (p <0.05). Conclusions: The area around the accident site was highly polluted with hydrogen fluoride according to the results of this study. Considering the persistency of hydrogen fluoride in the environment, long-term monitoring and environmental impact assessment should be pursued.

Hydrogen Absorption by Laves Phase Related BCC Solid Solution Alloys

  • Akiba, Etsuo
    • 한국수소및신에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.101-109
    • /
    • 1997
  • We propose a new concept of hydrogen absorbing alloy, "Laves phase related BCC solid solution". It was firstly found among the phases tormed in multicomponent nominal $AB_2$ alloys which consisted of Zr and Ti for the A metal site and 5A, 6A and 7A transition metals for the B metal sites. In these alloys a BCC solid solution often coexisted with a Laves phase. It showed stability of hydrides and reaction kinetics almost identical to intermetallics such as Laves phase alloys. We prepared an almost pure "Laves phase related BCC solid solution" and found that it had a large hydrogen capacity (more than 2 mass%) and fast hydrogen absorption and desorption kinetics at ambient temperature and pressure. This new hydrogen absorbing alloy may open a new era of hydrogen related application such as hydrogen vehicles.

  • PDF

SI 열화학싸이클 황산분해공정의 Bench-scale 상압 실험 (Bench-scale Test of Sulfuric Acid Decomposition Process in SI Thermochemical Cycle at Ambient Pressure)

  • 전동근;이기용;김홍곤;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제22권2호
    • /
    • pp.139-151
    • /
    • 2011
  • The sulfur-iodine (SI) thermochemical water splitting cycle is one of promising hydrogen production methods from water using high-temperature heat generated from a high temperature gas-cooled nuclear reactor (HTGR). The SI cycle consists of three main units, such as Bunsen reaction, HI decomposition, and $H_2SO_4$ decomposition. The feasibility of continuous operation of a series of subunits for $H_2SO_4$ decomposition was investigated with a bench-scale facility working at ambient pressure. It showed stable and reproducible $H_2SO_4$ decomposition by steadily producing $SO_2$ and $O_2$ corresponding to a capacity of 1 mol/h $H_2$ for 24 hrs.

Effect of Ambient Gases on the Characteristics of ITO Thin Films for OLEDs

  • Lee, Yu-Lim;Lee, Kyu-Mann
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권6호
    • /
    • pp.203-207
    • /
    • 2009
  • We have investigated the effect of ambient gases on the structural, electrical, and optical characteristics of ITO thin films intended for use as anode contacts in OLED (organic light emitting diodes) devices. These ITO thin films are deposited by radio frequency (RF) magnetron sputtering under different ambient gases (Ar, Ar+$O_2$, and Ar+$H_2$) at $300{^{\circ}C}$. In order to investigate the influences of the oxygen and hydrogen, the flow rate of oxygen and hydrogen in argon mixing gas has been changed from 0.5 sccm to 5 sccm and from 0.01 sccm to 0.25 sccm, respectively. The intensity of the (400) peak in the ITO thin films increased with increasing $O_2$, flow rate whilst the (400) peak was nearly invisible in an atmosphere of Ar+$H_2$. The electrical resistivity of the ITO thin films increased with increasing $O_2$ flow rate, whereas the electrical resistivity decreased sharply under an Ar+$H_2$ atmosphere and was nearly similar regardless of the $H_2$ flow rate. The change of electrical resistivity with changes in the ambient gas composition was mainly interpreted in terms of the charge carrier mobility rather than the charge carrier concentration. All the films showed an average transmittance of over 80% in the visible range. The OLED device was fabricated with different ITO substrates made with the configuration of ITO/$\alpha$-NPD/DPVB/$Alq_3$/LiF/Al in order to elucidate the performance of the ITO substrate. Current density and luminance of OLED devices with ITO thin films deposited in Ar+$H_2$ ambient gas is the highest among all the ITO thin films.

PEMFC 연료 공급관의 수소취성에 관한 연구 (Study on hydrogen embrittlement of fuel line for PEMFC)

  • 박광진;김정현;정재화;배중면
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1992-1996
    • /
    • 2007
  • This study focuses on the hydrogen embrittlement of iron tube for fuel line of PEMFC (Proton Exchange Membrane Fuel Cell). PEMFC is operated by feed of hydrogen as a reactant and steam for proton conductivity of membrane. However, the environment with hydrogen and steam occur the hydrogen-induced degradation in BOP system. When iron tube was exposed to hydrogen and steam condition for 24 hours, the oxide layer on the surface was decreased by reduction. When the ambient temperature was 90$^{\circ}C$ micro cracks were found on the surface than any other temperature. The mechanical strength of iron tube was 3% lower than that of non-experiment tube. Maximum tensile stress was decreased 8%.

  • PDF

직접분사식 수소연료의 분무 및 연소특성에 관한 연구 (A Study on the Characteristics of Injection and Combustion with Directly Injected Hydrogen Fuel)

  • 이성욱;기완수
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.24-29
    • /
    • 2007
  • This study aims to provide a fundamental data for directly injected hydrogen fuel engines. Spray, ignition and combustion characteristics of hydrogen were studied using constant volume chamber. For spray visualization, hydrogen was vertically injected into a combustion chamber at various condition, for example, injection pressure, ambient pressure. And an argon laser was used for the shadowgraph photography by applying optical method. Also, to investigate heat-release rate and flame propagations, spark was ignited on hydrogen injected at the different time after injection and the duration of injection was also changed. Processes of ignition and combustion were analyzed by heat-release rate calculated by pressure history and were observed by shadowgraph photography The results gave much knowledge of spray, ignition and combustion characteristics of hydrogen.

수소 혼합에 따른 덤프 연소기내의 연소 특성에 관한 실험적 연구 (An Experimental Study on the Combustion Characteristics with Hydrogen Enrichment in a Dump Combustor)

  • 김대희;홍정구;신현동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2977-2983
    • /
    • 2008
  • The combustion characteristics of a partially premixed flame in a dump combustor were studied to determine the effects of hydrogen enrichment in propane. Bluff-body was used for flame stabilization. Fuel mixtures containing a hydrogen mole fraction ranging from 0.1 to 0.5 were burnt at ambient pressure within a quartz chamber. Tests were carried out keeping the total reactant flow rate by adjusting the fuel and air flow rates. The fluctuations of pressure were measured by piezoelectric pressure sensor. The instantaneous flame structure and OH chemiluminescence images were described by High-speed Intensified Charged Coupled Device (HICCD) camera and Intensified Charged Coupled Device (ICCD) camera. The present results show that hydrogen enrichment in fuel changed the location of primary reaction zone from inner recirculation zone to turbulent shear layer and pressure signal. The reason is that chemical aspects take precedence over flow aspects in the hydrogen-enriched flame.

  • PDF

수중 환경에서 수소로 희석된 반응 가스를 이용하여 증착된 DLC 박막의 트라이볼로지 거동 (Tribological Behaviors of DLC Thin Films Deposited using Precursor Gas diluted by Hydrogen under Aqueous Environment)

  • 이진우;문명운;이광렬
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.338-339
    • /
    • 2012
  • This study examined the friction and wear behavior of diamond-like carbon (DLC) films deposited from a radio frequency glow discharge using a hydrogen diluted benzene gas mixture. The DLC films were deposited on Si (100) and polished stainless steel substrates by r.f.-PACVD at hydrogen to benzene ratios, or the hydrogen dilution ratio, ranging from 0 to 2.0. The wear test was carried out in both ambient and aqueous environments using a home-made ball-on-disk type wear rig. The stability of the DLC coating in an aqueous environment was improved by diluting the benzene precursor gas with hydrogen, suggesting that hydrogen dilution during the deposition of DLC films suppress the initiation of defects in the film and improved the adhesion of the coating to the interface.

  • PDF