• 제목/요약/키워드: Hydrogen Sulfide Gas

검색결과 227건 처리시간 0.034초

Pt/CNT 전극 기반 전기화학식 센서의 전해질에 따른 황화수소 감지 특성 (Hydrogen Sulfide Sensing Characteristics Depending on Electrolytes of Pt/CNT Liquid Electrochemical Sensors)

  • 하윤태;권진범;최수지;백수빈;정대웅
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.194-198
    • /
    • 2023
  • With the recent development of industrial technology, the problem of odor due to leakage of toxic gas discharged from industrial complexes is gradually increasing. Among them, hydrogen sulfide is a colorless representative odorous substance that can cause pain through irritation of the mucous membranes of the eyes and respiratory tract, and is a gas that can cause central nervous system paralysis and suffocation when exposed to high concentrations. Therefore, in order to improve the odor problem, research on a gas sensor capable of quickly and reliably detecting a leak of hydrogen sulfide is being actively conducted. A lot of research has been done on the existing metal oxide-based hydrogen sulfide gas sensor, but it has the disadvantage of requiring low selectivity and high temperature operating conditions. Therefore, in this study, a Pt/CNT-based electrochemical hydrogen sulfide gas sensor capable of detecting at low temperatures with high selectivity for hydrogen sulfide was developed. A working electrode capable of selectively detecting only hydrogen sulfide was fabricated by synthesizing Pt nanoparticles as a catalyst on functionalized CNT and applied to an electrochemical hydrogen sulfide gas sensor. It was confirmed that the manufactured Pt/CNT-based electrochemical hydrogen sulfide gas sensor has a current change of up to 100uA for hydrogen sulfide, and the both response time and recovery time were within 15 seconds.

3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작 (Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing)

  • 하윤태;권진범;최수지;정대웅
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

A Study on Pattern Analysis of Odorous Substances with a Single Gas Sensor

  • Kim, Han-Soo;Choi, Il-Hwan;Kim, Sun-Tae
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.423-430
    • /
    • 2016
  • This study used a single metal oxide semiconductor (MOS) sensor to classify the major odorous gases hydrogen sulfide ($H_2S$), ammonia ($NH_3$) and toluene ($C_6H_5CH_3$). In order to classify these odorous substances, the voltage on the MOS sensor heater was gradually reduced in 0.5 V steps 5.0 V to examine the changes to the response by the cooling effect on the sensor as the voltage decreased. The hydrogen sulfide gas showed the highest sensitivity compared to odorless air under approximately 2.5 V and the ammonia and toluene gases showed the highest sensitivity under approximately 5.0 V. In other words, the hydrogen sulfide gas reacted better in the low temperature range of the MOS sensor, and the ammonia and toluene gases reacted better in the high-temperature range. In order to analyze the response characteristics of the MOS sensor by temperature in a pattern, a two-dimensional (2D) x-y pattern analysis was introduced to clearly classify the hydrogen sulfide, ammonia, and toluene gases. The hydrogen sulfide gas was identified by a straight line with a slope of 1.73, whereas the ammonia gas had a slope of 0.05 and the toluene gas had a slope of 0.52. Therefore, the 2D x-y pattern analysis is suggested as a new way to classify these odorous substances.

악취측정용 10 μmol/mol 황화수소 표준가스 개발 (Development of 10 μmol/mol Hydrogen Sulfide Primary Standard Gas for Odor Measurements)

  • 김용두;배현길;김달호;오상협;이진홍;이상일
    • 한국가스학회지
    • /
    • 제22권2호
    • /
    • pp.46-51
    • /
    • 2018
  • 산업이 급속하게 발전함에 따라 자연 대기에서 악취를 유발하는 매우 적은 양의 황화수소가 존재합니다. 매립 및 하폐수처리장에서 나오는 황화수소 성분은 대기에 존재하므로 많은 민원이 발생됩니다. 민원이 발생하는 악취가스를 측정하기 위해 $10{\mu}mol/mol$ 농도 수준의 황화수소 인증표준물질(Certified reference material)을 개발하고자 하였다. 질소 안에 $10{\mu}mol/mol$ 수준의 황화수소 가스 제조는 ISO 6142에 의한 중량법을 사용하였다. 4 개의 알루미늄 실린더에 가스 CRM을 제조하고 GC-AED로 그 농도를 확인했습니다. 제조의 불확도는 0.50 % 미만이었고, 제조일치성은 0.22 %이었다. 실린더의 내부 흡착은 1500 psi에서 0.10 %이었고 1 년 동안 장기간 안정한 것으로 평가되었다. 이 황화수소 CRM의 제조 일치성, 실린더의 흡착 및 장기 안정성에 대한 상대 확장불확도는 1.05 %(신뢰도 95 %, k = 2) 이내로 개발되었다.

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF

계사 및 우사 내 암모니아 및 황화수소 노출농도 평가 (Ammonia and Hydrogen Sulfide Monitoring in Broiler Barns and Cattle Barns)

  • 박지훈;석지원;이상아;권오훈;이경숙;허용;윤충식
    • 한국환경보건학회지
    • /
    • 제41권5호
    • /
    • pp.277-288
    • /
    • 2015
  • Objectives: There are many hazardous agents at livestock farms. In particular, gases can be detrimental to both workers and animals. This study evaluated ammonia and hydrogen sulfide concentrations in broiler hen barns and beef cattle barns according to sampling location and height. Methods: Three broiler hen barns and three beef cattle barns were selected for gas monitoring in this study. Ammonia and hydrogen sulfide concentrations were measured using a direct-reading instrument which could measure the target gases simultaneously. Gas monitoring was conducted at human breathing height and animal breathing height at three points in each livestock farm. Results: Ammonia concentrations at the broiler hen barns ranged from 3.3 to 12.5 ppm by sampling location and height, but hydrogen sulfide was not detected. In the beef cattle barns, ammonia ranged from 3.1 to 16.3 ppm and low concentrations of hydrogen sulfide were detected at some animal breathing heights. The gas concentrations detected at each livestock farm were significantly higher in the animal breathing zones than in human breathing zones (p<0.0001). Conclusions: We found a difference in gas concentrations between human breathing zones and animal breathing zones. Gas monitoring should be conducted to improve the related environment considering both workers' and animals' health and safety.

Evaluation of Hydrogen Sulfide Corrosion Inhibitors for Wet Gas Pipeline Steel

  • Huy, Vu Dinh;Thoa, Nguyen Thi Phuong;Phong, Tran Quoc;Hoang, Nguyen Thai
    • Corrosion Science and Technology
    • /
    • 제4권3호
    • /
    • pp.95-99
    • /
    • 2005
  • Wheel test and potentiodynamic polarization methods were used to evaluate the relative effectiveness of some hydrogen sulfide corrosion inhibitors for the wet gas pipeline API 5L grade X 65 steel. Five commercially corrosion inhibitors have been studied in the deoxygenated produced water solutions containing 10 ppm and 100 ppm of hydrogen sulfide. Based on the experiment results the steel corrosion inhibition mechanism in discussed and two most effective corrosion inhibitors are selected.

황화수소가스에 노출된 후 혼수로 내원한 환자 2례 (Two Cases of Comatose Patients Presenting after Exposure to Hydrogen Sulfide Gas)

  • 류현호;이병국;정경운;허탁;민용일
    • 대한임상독성학회지
    • /
    • 제7권1호
    • /
    • pp.26-31
    • /
    • 2009
  • Hydrogen sulfide is a by-product of decayed organic material and is ubiquitously found as an ingredient of manufacturing reagents or as an undesirable by-product of the manufacturing or industrial processing. Hydrogen sulfide is a chemical asphyxiant and interferes with cytochrome oxidase and aerobic metabolism. It has thus been deemed an important cause of work-related sudden death. This gas is particularly insidious due to the unpredictability of its presence and concentration and its neurotoxicity at relatively low concentrations, causing olfactory nerve paralysis and loss of the warning odor. Here, we report two cases of comatose patients presenting after accidental exposure to hydrogen sulfide gas.

  • PDF

급속한 의식 변화를 초래한 급성 황화수소 중독 1례 (A Case of Acute Hydrogen Sulfide Intoxication Caused Rapid Loss of Consciousness)

  • 안정환;정윤석
    • 대한임상독성학회지
    • /
    • 제2권2호
    • /
    • pp.147-150
    • /
    • 2004
  • Hydrogen sulfide is a colorless, and malodorous 'rotten eggs' gas that results from the decay of organic material. It is a byproduct of industry and agriculture. The mechanism of its toxicity is primarily related to inhibition of oxidative phosphorylation, which causes a decrease in available cellular energy. Because there is no rapid method of detection that is of clinical diagnostic use, management decisions must be made based on history, clinical presentation, and diagnostic tests that imply hydrogen sulfide's presence. Although there is some anecdotal evidence to suggest that the early use of hyperbaric oxygen is beneficial, supportive care remains the mainstay of therapy. We describe an occupational exposure to hydrogen sulfide gas in 51-year-old man. While cleaning the sewage of pigs. he became unconscious. When he arrived in the emergency department, he had irritability and confused mentality. The typical smell of rotten eggs on clothing and exhaled air were enough to be considered to be exposed to hydrogen sulfide. Hyperbaric oxygen therapy was performed. He had a recovery to normal function.

  • PDF

Evaluation of Short-Term Exposure Levels on Ammonia and Hydrogen Sulfide During Manure-Handling Processes at Livestock Farms

  • Park, Jihoon;Kang, Taesun;Heo, Yong;Lee, Kiyoung;Kim, Kyungran;Lee, Kyungsuk;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.109-117
    • /
    • 2020
  • Background: Ammonia and hydrogen sulfide are harmful gases generated during aerobic/anaerobic bacterial decomposition of livestock manure. We evaluated ammonia and hydrogen sulfide concentrations generated from workplaces at livestock farms and determined environmental factors influencing the gas concentrations. Methods: Five commercial swine farms and five poultry farms were selected for monitoring. Real-time monitors were used to measure the ammonia and hydrogen sulfide concentrations and environmental conditions during the manure-handling processes. Monitoring was conducted in the manure storage facility and composting facility. Information on the farm conditions was also collected through interview and walk-through survey. Results: The ammonia concentrations were significantly higher at the swine composting facilities (9.5-43.2 ppm) than at other manure-handling facilities at the swine and poultry farms, and high concentrations of hydrogen sulfide were identified during the manure agitation and mixing process at the swine manure storage facilities (6.9-19.5 ppm). At the poultry manure-handling facilities, the ammonia concentration was higher during the manure-handling processes (2.6-57.9 ppm), and very low hydrogen sulfide concentrations (0-3.4 ppm) were detected. The air temperature and relative humidity, volume of the facility, duration of manure storage, and the number of animals influenced the gas concentrations. Conclusion: A high level of hazardous gases was generated during manure handling, and some levels increased up to risk levels that can threaten workers' health and safety. Some of the farm operational factors were also found to influence the gas levels. By controlling and improving these factors, it would be possible to protect workers' safety and health from occupational risks.