Presumption of Slipper-pad Fault Condition for Hydraulic Rotary Actuator (마멸입자 해석을 통한 유압로터용 Slipper - Pad의 손상상태 추정)

  • 전성재;조연상;서영백;박흥식
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.62-67
    • /
    • 2000
  • This paper was undertaken to do morphological analysis of wear debris for slipper-Pad of hydraulic rotary acuator. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four shape parameters(50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear debris. The results showed that the four shape parameters of wear debris depend on a kind of the lubricating condition. It was capable of presuming wear volume for slipper-pad of hydraulic rotary acuator on driving time.

  • PDF

Analysis of Wear Characteristics for Sliding Members of Hydraulic Rotary Actuator (유압피스톤 습동재료의 마멸특성 해석)

  • 김성희;김동호;이광영;박흥식;전태옥
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.101-108
    • /
    • 1999
  • This paper was undertaken to do morphological analysis of wear particles for sliding members hydrauric rotary acuator. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear particles. The results showed that the four shape parameters of wear particles depend on a kind of the lubricating materials. It was capable of presuming wear volume for three kinds of materials on driving time.

  • PDF

Analysis of Surplus Flow in a Hydraulic System Applied to a Self-propelled Spinach Harvester (자주식 시금치 수확장치에 적용된 유압시스템의 잉여유량 분석)

  • Noh, Dae Kyung;Lee, Dong Won;Lee, Jong Su;Jang, Joo Sup
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2022
  • This study dealt with a self-propelled spinach harvester, which is capable of carrying out sequential harvesting work. This study aimed to find the cause of the harvester's occasional performance deterioration, which occurs in the process of simplifying the hydraulic circuit, using a multi-domain analysis model. The study was carried out in the following manner. First, a hydraulic system analysis model, which combines linear motion, rotary motion, hydrodynamic behavior, and an electrical signal, was developed through SimulationX software, specialized in multi-domain analysis. Second, a scenario for single behavior and coupled behavior was set out on an actuator basis. Third, the flow rate of the hydraulic system, which is not required for the movement of the actuator, was quantitatively analyzed. The results showed that a change in oil temperature was the cause of the harvester's occasional performance deterioration. And the higher the oil temperature, the more serious the performance deterioration, especially as the number of actuators operated simultaneously was small.

Research to Predict the Thermal Characteristics of Electro Hydrostatic Actuator for Aircraft (항공기용 전기-정유압식 작동기(Dual Redundant Asymmetric Tandem EHA)의 열특성 예측을 위한 연구)

  • Kim, Sang Seok;Park, Hyung Jun;Kim, Daeyeon;Kim, Dae Hyun;Kim, Sang Beom;Lee, Junwon;Choi, Jong Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.84-92
    • /
    • 2022
  • The electro-hydrostatic actuator (EHA) recently has been used in flight control fields for aircraft because of its benefits of minimizing oil leakage and weight, improving safety, and etc. while independently operating the hydraulic power source and eliminating complex hydraulic piping. The aircraft of which EHA is installed inside, has the thermal management issue of EHA, because of its limited cooling source as compared with the aircraft which installs the traditional central hydraulic system. So, the thermal analysis model which predicts the thermal characteristics of EHA, is required to resolve this thermal management issue. In this study, an oil circulation circuit inside the hydraulic power module comprised of hydraulic pump and electrical motor for EHA was applied. This is for the purpose of developing the internal rotary group of hydraulic power module, which operates under the conditions of high rotation speed and hydraulic pressure. After formulating an appropriate thermal analysis model, the thermal analysis results with oil cooled or no oil cooled hydraulic control module were compared and reviewed, for the purpose of predicting the thermal characteristics of EHA.

Performance Analysis Model for Flap Actuation System using MATLAB/Simulink

  • Cho, Hyunjun;Joo, Choonshik;Kim, Kilyeong;Park, Sangjoon
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • In this paper, we present some results on performance analysis for flap actuation system of aircraft. For this, by utilizing MATLAB/Simulink solution, which is widely used physical model-based design tool, we particularly construct the architecture of the analysis model consisting of the main three phases: 1)commanding and outer-controlling the flap angle through flight control computer; 2)generating hydraulic/mechanical power through control module and power drive unit; 3)transmitting torque and actuating the flap through torque tube and rotary geared actuators. For mimicking the motion of the actual flap, we apply each mechanical component, which is already being used in actual aircraft, to our performance analysis model so that it guarantees the congruency of the simulation results. That is, we reflect the actual specifications of flap hardware and software as parameters of the model. Finally, simulation results are presented to illustrate the model.

Study on the Damping Mechanism of an Hydraulic Type Automotive Seat Damper (자동차용 유압식 시트댐퍼의 댐핑 메카니즘에 관한 연구)

  • Lee, Choon Tae
    • Journal of Drive and Control
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 2016
  • Typically, the seat of an automotive vehicle generally includes a horizontal seat-cushion portion and a vertical seat-back portion that is operatively connected to the seat-cushion portion. The seat may include a recliner for the reclining of the seat-back portion relative to the seat-cushion portion by the seat occupant. An energy absorber or damper can also be provided for the seat-back portion. Because the recliner is configured to be released at a relatively high speed, and it results in an impact at the end of a folding stroke, the damper needs to dissipate energy as the seat back moves with respect to the seat cushion; therefore, the role of the seat damper in the automotive-seat design is important. In this paper, the mechanism of an hydraulic-type automotive-seat damper is investigated, and the torque characteristic is simulated according to the design-parameter variations such as the orifice area and the working-fluid properties.

Development of a Large Capacity Hybrid-Type Linear Motor Damper for the vibration Control of Building Structures (건축 구조물의 진동 제어용 하이브리드형 대용량 리니어 모터 댐퍼의 개발)

  • Jeong, Sang-Seop;Jang, Seok-Myeong;Lee, Seong-Ho;Yun, In-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.601-611
    • /
    • 2002
  • As resent trends in structural construction have been to build taller and larger structures than any time in the past, they have had high flexibility and low damping that can cause large vibration response under severe environmental loading such as earthquakes, winds, and mechanical excitations. The damper with mass and sqring is one aproach to safeguarding the structure against excessive vibrations. In this paper, a large capacity hybrid-type linear motor damper(LMD) was designed and fabricated for the application to the vibration control of a large building structure model. It has been designed to be able to move the damper mass, 1,500 kg up to ${\pm}250mm$ strokes at the first mode natural frequency of the building structure model, ${\pm}0.51Hz$. Linear motor is consisted of the fixed coil and the movable NdFeB permanent magnets field part. The PM field part composed magnet modules and iron yoke, is the damper mass itself, 1500kg. LMD therefore has a simplified structure and requires a few elements in the driving system, being compared with a rotary motor damper and a hydraulic damper. However, the manufacture of large PM linear actuator is difficult because of the limit of PM size and the attraction and repulsion at the assembly of PM. Therefore, large damper system is manufactured and tested for dynamic characteristics and frequency response.