• Title/Summary/Keyword: Hydraulic Pressure Test

Search Result 483, Processing Time 0.033 seconds

Determination of pressure-Dependent Yield . Criterion for Polymeric Foams (폴리머 폼 재료의 정수압 종속 항복조건 결정에 관한 연구)

  • 김영민;강신일
    • Transactions of Materials Processing
    • /
    • v.11 no.1
    • /
    • pp.69-74
    • /
    • 2002
  • In addition to lightweight and moldable characteristics, polymeric foams possess an excellent energy absorbing capability that can be utilize for a wide range of commercial applications, especially in the crashworthiness of the automobiles. The purpose of the present study is to develop experimental methodology to characterize the pressure dependent yield behavior of the energy absorbing polymeric foams. For the compression test in a triaxial stress sate, a specially designed device was placed in a hydraulic press to produce and control oil pressure. For the test material, the polyurethane foams of two different densities were used. The displacement of the specimen, the load subjected to the specimen, and oil pressure applied to the specimen were measured and controlled. Stress strain curves and yield stresses for the four different oil pressure were obtained. It was found from the present experiments that the polyurethane foams exhibited significant increases in yield stress with applied pressure or mean normal stress. Based on this observation, a yield criteria which included the effect of the stress invariant were established for the polymeric foams. The obtained experimental constants which constituted the pressure-dependent yield criterion were verified.

International Joint Research for the Colloid Formation and Migration in Grimsel Test Site: Current Status and Perspectives

  • Sang-Ho Lee;Jin-Seok Kim;Bong-Ju Kim;Jae-Kwang Lee;Seung Yeop Lee;Jang-Soon Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.455-468
    • /
    • 2022
  • Colloid Formation and Migration (CFM) project is being carried out within the Grimsel Test Site (GTS) Phase Ⅵ. Since 2008, the Korea Atomic Energy Research Institute (KAERI) has joined CFM to investigate the behavior of colloid-facilitated radionuclide transport in a generic Underground Research Laboratory (URL). The CFM project includes a long-term in-situ test (LIT) and an in-rock bentonite erosion test (i-BET) to assess the in-situ colloid-facilitated radionuclide transport through the bentonite erosion in the natural flow field. In the LIT experiment, radionuclide-containing compacted bentonite was equipped with a triple-packer system and then positioned at the borehole in the shear zone. It was observed that colloid transport was limited owing to the low swelling pressure and low hydraulic conductivity. Therefore, a postmortem analysis is being conducted to estimate the partial migration and diffusion of radionuclides. The i-BET experiment, that focuses more on bentonite erosion, was newly designed to assess colloid formation in another flow field. The i-BET experiment started with the placement of compacted bentonite rings in the double-packer system, and the hydraulic parameters and bentonite erosion have been monitored since December 2018.

A Study on Injection Nozzle and Internal Flow Velocity for Removing Air Bubbles inside the Sample Tanks during Hydraulic Rupture Test (수압파열시험 시 시료 탱크 내부 기포 제거를 위한 주입 노즐 및 내부 유속 연구)

  • Yeseung, Lee;Hyunseok, Yang;Woo-Chul, Jung;Dong Hoon, Lee;Man-Sik, Kong
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.9-15
    • /
    • 2022
  • In order to verify the durability of the high-pressure hydrogen tank in the operating pressure range, a hydraulic rupture test should be performed. However, if the bubbles generated by the initial injection process of water are attached to the inner wall of the tank and remain, a sudden pressure change of the bubbles during the rupture of the pressurized tank may cause shock and noise. Therefore, in this study, the flow velocity required to remove the bubbles remaining on the inner wall of the tank was predicted through simplified formulas, and the shape of the injection nozzle to maintain the flow velocity was determined based on the shape of the hydrogen tank for the hydrogen bus. In addition, a numerical model was developed to predict the change in flow velocity according to the inlet pressure, and an experiment was performed through a model tank to prove the validity of the prediction result. As a result of the experiment, the flow velocity near the tank wall was similar to the predicted value of the analysis model, and when the inlet pressure was 1.5 to 5.5 bar, the minimum size of the removable bubble was predicted to be about 2.2 to 4.6 mm.

Measurement of Real Deformation Behavior in C-type Lng Mock-up Tank using Strain Gage (스트레인 게이지를 이용한 C-type LNG Mock-up 탱크 내조 실 변형 거동 측정)

  • Jung, Won-Do;Kim, Tae-Wook;Kim, Jeong-Hyeon;Lee, Do-Young;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • A C-type LNG mock-up tank was constructed to evaluate the durability of the tank and its structural safety. An experimental strain analysis system equipped with strain gages was designed to investigate the structural behavior of the inner tank at a high hydraulic pressure. In addition, the insulation used in the space between the inner tank and outer tank had a compressive strength and the inner tank thickness of the cylindrical shell and hemisphere was 4.0 mm, which was designed to be thinner than the existing rules. The strains on the inner tank were measured with increasing pressure, and these measurements were compared and analyzed at the strain gage attachment points.

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

Stress and Thermal Analyses of Pressure Housing of SMART CEDM (SMART제어봉구동장치의 압력용기에 대한 응력 및 열해석)

  • 조대희;유제용;김지호;김종인
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.343-350
    • /
    • 2002
  • The structural stability of pressure housing of SMART CEDM forming pressure boundary must be evaluated. In this paper, the stress and thermal analyses of the upper pressure housing of CEDM are performed for design pressure, hydraulic test pressure and thermal loading. Finite element and boundary condition were generated from the model which is made by I-DEAS program and the stress and thermal analyses were performed by ANSYS Program. The upper Pressure housing was analysed using 2D axisymmetric model because it is symmetry about an axis. The stress values obtained by analysis were compared with the stress intensity limit of ASME and KEPIC MNB standard.

  • PDF

Thermal-Hydraulic Test Facilities and Some Test Results of Integrated Heating Reactors

  • Jia, Haijun;Wu, Shaorong;Jiang, Shengyao
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.211-216
    • /
    • 1996
  • Since the middle of the eighties of this century a research program both for heating reactor and investigation of heating reactor thermal-hydraulics has been carried out in Institute of Nuclear Energy Technology(INET) of Tsinghua university in China. This kind of heating reactor is a light water cooled and integrated natural circulation reactor with low system pressure and low quality at the exit of core. Because of relatively long riser and low system pressure. a little change of the quality at the exit of the core will result in a relatively large variation of void fraction in the riser. Two full scale test loops. HRTL-5 and HRTL-200 simulating the HR-5 and HR-200 heating reactors in geometry and operation parameters respectively, and some test results from the HRTL-200 test facility are shown in this paper. The range of studied system pressure is from 1.0MPa to 4.0MPa, the largest heat flux is about 50 W/cm2, and the quality at the exit of test section is less than 5%.

  • PDF

Development and Hydraulic Characteristics of Continuous Block System in River Bank Protection (I) - Development and Application Review through Hydraulic Model Test - (일체형 식생호안블록 시스템 개발 및 수리특성 연구(I) -일체형 호안블록 개발 및 수리모형실험을 통한 적용성 검토-)

  • Jang, SukHwan
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.87-97
    • /
    • 2008
  • This research focused on development and application feasibility for the coalesced continuous block system in river bank protection. Most of block systems in river bank are pre cast type and have some difficulties against high velocity flood condition or high pressure load, however, the continuous block system can be applied to flood damage recover as well as environmental vegetation block system in river bank. For the application review and analysis of hydraulic condition for this block system, hydraulic physical modeling was carried out. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for vegetation application or not. In consequence, the water velocities were observed to decrease meanly 10.1%, and the water depths were to increase meanly 17.8% in case of the of design flood, $Q=200m^3/sec$. To verify the hydraulic physical modeling, the numerical modeling should be conducted for a close examination of vegetation application by one or two dimensional numerical analysis as a next study.

  • PDF

Numerical analysis of vertical drains accelerated consolidation considering combined soil disturbance and visco-plastic behaviour

  • Azari, Babak;Fatahi, Behzad;Khabbaz, Hadi
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-220
    • /
    • 2015
  • Soil disturbance induced by installation of mandrel driven vertical drains decreases the in situ horizontal hydraulic conductivity of the soil in the vicinity of the drains, decelerating the consolidation rate. According to available literature, several different profiles for the hydraulic conductivity variation with the radial distance from the vertical drain, influencing the excess pore water pressure dissipation rate, have been identified. In addition, it is well known that the visco-plastic properties of the soil also influence the excess pore water pressure dissipation rate and consequently the settlement rate. In this study, a numerical solution adopting an elastic visco-plastic model with nonlinear creep function incorporated in the consolidation equations has been developed to investigate the effects of disturbed zone properties on the time dependent behaviour of soft soil deposits improved with vertical drains and preloading. The employed elastic visco-plastic model is based on the framework of the modified Cam-Clay model capturing soil creep during excess pore water pressure dissipation. Besides, nonlinear variations of creep coefficient with stress and time and permeability variations during the consolidation process are considered. The predicted results have been compared with V$\ddot{a}$sby test fill measurements. According to the results, different variations of the hydraulic conductivity profile in the disturbed zone result in varying excess pore water pressure dissipation rate and consequently varying the effective vertical stresses in the soil profile. Thus, the creep coefficient and the creep strain limit are notably influenced resulting in significant changes in the predicted settlement rate.