• Title/Summary/Keyword: Hydraulic Power Unit

Search Result 96, Processing Time 0.029 seconds

Daily Operating Characteristics of Desalination System with Solar Energy (태양에너지 해수담수화 시스템 일일 운전 특성)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.262-265
    • /
    • 2009
  • This study was carried out to evaluate the clear day operating performances for the decentralized desalination system with the solar thermal system and the photovoltaic power system. In a clear day, we used a solar thermal system as heat source of the single-stage fresh water generator with plate-type heat exchangers and a photovoltaic power system as electric source for hydraulic pumps. The demonstration system generation was designed and installed at Jeju-island in 2006. The system was comprised of the desalination unit with daily fresh water capacity designed as $2m^3$, a $120m^3$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity of hydraulic pumps for the heat medium fluids. In a clear day, solar irradiance daily averaged was measured $518W/m^3$, the daily fresh water yield showed that about 565 liter.

  • PDF

Design of a 50kW Class Rotating Body Type Highly Efficient Wave Energy Converter (50kW급 가동물체형 고효율 파력발전시스템 설계)

  • Cho, Byung-Hak;Yang, Dong-Soon;Park, Shin-Yeol;Choi, Kyung-Shik;Park, Byung-Chul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.552-558
    • /
    • 2011
  • A 50 kW class rotating body type wave energy converter consisted of two floating bodies and a PTO (Power Takeoff) unit is studied. As an wave energy extractor, the body is designed to have a VLCO (Variable Liquid-Column Oscillator) having a liquid filled U-tube with air chambers. Owing to the oscillation of the liquid in the U-tube caused by the air spring effect of the air chambers, the amplitude of response of the VLCO becomes significantly amplified for a target wave period. The PTO converts the rotational moment introduced from the relative motion of the hinged bodies to an hydraulic power by means of a cylinder. A high pressure accumulator, hydraulic motor and a generator are equipped in the PTO to convert the hydraulic power to electric power. A control law for adjusting the oscillation period of the VLCO is proposed for the efficient operation of the VLCO with various wave conditions. It is found that the effect of the air spring has an important role to play in making the oscillation of the VLCO match with the ocean wave. In this way, the wave energy converter equipped with the VLCO provides the most effective mode for extracting energy from the ocean wave.

Structural Safety Evaluation for the Hydraulic Power Unit of Topside Module According to the Movement of Offshore Plant (해양구조물 움직임에 따른 Topside Module의 HPU에 대한 구조안전성 평가)

  • Ryu, Bo-Rim;Lee, Jin-Uk;Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.723-731
    • /
    • 2020
  • The design of offshore plants should reflect the various requirements of the owner and the classification society. For a topside module mounted on an of shore structure, the design process is very demanding because of the large spatial constraints and the many requirements related to marine environmental conditions and safety such as the movement of the structure. In this study, the load acting on the hydraulic power unit, which is one of the main equipment in the topside module, was calculated according to the DNVGL rule; the structural safety was evaluated according to each load condition and the structural reliability of the developed product was improved. For structural analysis, MSC software was used, and structural analysis was performed under five load conditions to review structural safety for various movements. The results show that the maximum stress occurred during pitching toward the stern (Load Case 5). The stress level was approximately 85 % of the allowable stress, and the maximum deformation was approximately 5 % of the allowable value. The structural safety was confirmed, and no intermember interference occurred.

Assessment of RELAP5/MOD2 Code using Loss of Offsite Power Transient of Kori Unit 1 (고리 1호기 외부 전원 상실사고에 의한 RELAP5/MOD2코드 모델 평가)

  • Chung, Bub-Dong;Kim, Hho-Jung;Lee, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.12-19
    • /
    • 1990
  • The Loss of Offsite Power Transient at 77.5% power which occurred on June 9, 1981 at the Kori Unit 1 PWR (Pressurized Water Reactor) is simulated using the RELAP5/MOD2 system thermal-hydraulics computer code. Major thermal-hydraulic parameters are compared with the available plant data. The comparison of the analysis results with the plant data demonstrates that the RELAP5/MOD2 code has the capability to simulate the thermal-hydraulic behaviour of PWRs under accident conditions of this type with accuracy, except the pressurizer pressure and level. The pressurizer pressure increase is sensitive to the in surge now it is believed that the interracial heat transfer in a horizontal stratified flow regime may be estimated low and the compression effect due to insurge flow may be high. In the nodalization sensitivity study it is found that S/G noding with junctions between bypass plenum and steam dome is preferred to simulate the S/G water level decreasing and avoid the spurious level peak at trubine trip.

  • PDF

Development on Governor of electronic oil pressure type for stt:am turbine of thermal power plant (전자유압식 Governor의 개발 :화력발전소증기 turbine에 있어서의 해외논초)

  • 대한전기학회
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.35-37
    • /
    • 1968
  • 증기 Turbine plant의 제어방식은 점점 더 복잡하게 고도화하고 있으며 원심 또는 유압조속기등 Lever와 유압기구의 조합으로 구성된 기계유압식 Governor 대신에 전자유압식 Governor(Electro-Hydraulic Governor, EHG 일반적으로 광의의 의미로는 전자유압식제어장치 Electro-Hydraulic Control System이라함)의 개발에 주력하고 있으며 본보고서는 이에 대한 시험결과를 기술한 것이다. 본보고서는 산업용(자가발전용) 증기 Turbine의 전자유압식 Governor에 관한 것으로서 기계유압식에서의 복잡한 Lever 기구, Relay 장치등 기계부분의 전자유압화와 고압제어유의 채용및 이에 따르는 각부분의 Module화, Solid State화 및 소형 Unit화에 의하여 취급및 보수가 용이한 고성능의 제어장치를 개발하게 되었다. 특히 미국의 GE사에서 이에 대한 개발이 앞서 있으며 현재 100MW까지 약 30대가 실용화되고 있다고 한다. (이글은 일본화력발전지 1968년 1월 제136호에서 발췌한 글이다.)

  • PDF

Fuzzy Control of Speed Ratio for Electro-Hydraulic Rig Type CVT (전자 유압식 리그형 CVT의 변속비 퍼지제어)

  • Kim, S.H.;Kim, K.W.;Kim, H.S.;Eun, T.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.63-73
    • /
    • 1993
  • In this paper, fuzzy control algorithm for the speed ratio control of the electro-hydraulic rig type continuously variable transmission(CVT) was proposed and the CVT performance tests were carried out for the optimal operation of the engine simulator. The experimental results for the constant throttle and the acceleration modes showed that the engine can be run on the optimum operating line, representing the power and economy mode, by the fuzzy control of the CVT speed ratio. Comparing the PID control with the fuzzy control, it was found that the fuzzy control showed better performance with the faster rising time and smaller steady state error. The result of this study can be used as basic design materials for developing the transmission control unit of the CVT.

  • PDF

Remote control of Drum/Chute mechanism in a concrete mixer-truck (콘크리트 믹서 트럭에서의 드럼 및 슈트의 원격 제어)

  • Lee, M.C.;Son, K.;Jeong, W.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.22-29
    • /
    • 1993
  • A remote control system was developed in order to operate by push-buttons the conventional drum and chute components, which have been operated manually, in a concrete mixer-truck. As actuators, a hydraulic power unit was used for chute operations: two DC motors for drum operations. The devised drum controller consisted of three electric circuits : an analog proportional-integral control circuit, a drum acceleration circuit, and an emergency stop circuit. The remote control system was installed to be tested experimentally and then was evaluated to work successfully with a desirable accuracy.

  • PDF

Hydrogeological characteristics of the LILW disposal site (처분부지의 수리지질 특성)

  • Kim, Kyung-Su;Kim, Chun-Soo;Bae, Dae-Seok;Ji, Sung-Hoon;Yoon, Si-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.245-255
    • /
    • 2008
  • Korea Hydro and Nuclear Power Company(KHNP) conducted site investigations for a low and intermediate-level nuclear waste repository in the Gyeong Ju site. The site characterization work constitutes a description of the site, its regional setting and the current state of the geosphere and biosphere. The main objectives of hydogeological investigation aimed to understand the hydrogeological setting and conditions of the site, and to provide the input parameters for safety evaluation. The hydogeological characterization of the site was performed from the results of surface based investigations, i.e geological mapping and analysis, drilling works and hydraulic testing, and geophysical survey and interpretation. The hydro-structural model based on the hydrogeological characterization consists of one-Hydraulic Soil Domain, three-Hydraulic Rock Domains and five-Hydraulic Conductor Domains. The hydrogeological framework and the hydraulic values provided for each hydraulic unit over a relevant scale were used as the baseline for the conceptualization and interpretation of flow modeling. The current hydrogeological characteristics based on the surface based investigation include some uncertainties resulted from the basic assumption of investigation methods and field data. Therefore, the reassessment of hydrostructure model and hydraulic properties based on the field data obtained during the construction is necessitated for a final hydrogeological characterization.

  • PDF

Operating performance of desalination system with solar energy (태양에너지 해수담수화 시스템 운전 성능)

  • Kwak, Hee-Youl;Yoon, Eung-Sang;Joo, Moon-Chang;Joo, Hong-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.250-255
    • /
    • 2009
  • This study was analyzed the long term performance of the demonstration system for solar energy desalination in Jeju. we used a solar thermal system as heat source of the single-stage fresh water generator with plate-type heat exchangers and a photovoltaic power system as electric source for hydraulic pumps. The demonstration system was designed and installed at Jeju-island in 2006. The system was comprised of the desalination unit with daily fresh water capacity designed as $2m^3$ a $120m^2$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation to supply the electricity of hydraulic pumps for the heat medium fluids. Through the operation during about 3 years, In a clear day more than $400W/m^2$, the daily fresh water showed to produce more than about 500liter, and from January, 2007 to March, 2009 for 3 years, solar irradiance daily averaged was measured $370W/m^2$, the daily fresh water yield showed that can be produced about 330liter.

  • PDF

Development of the Linear Piston Pump Driven by the Hydraulic Power for the Solid Transferring (고형물 이송을 위한 유압구동 선형 피스톤 펌프의 개발)

  • Kim, Bong-Hwan;Ahn, Kook-Chan;Chung, Sung-Won;Kim, Young-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.82-89
    • /
    • 2009
  • The purpose of this study is to investigate the actual field application of the linear piston pump for the solid transferring driven by the hydraulic power unit. In this paper, the numerical analysis and performance evaluating experiments were performed. CFX program has been used to obtain the solutions for the problems of three-dimensional, turbulent water flow in the linear piston pump. The velocity and the pressure distributions are obtained using the turbulent $k-\varepsilon$ model. To evaluate the performance of the linear piston pump, the performance test stand and data acquisition system were manufactured. The numerical predictions agree favorably with experimental results within 7% error. Speed of the piston which is satisfied the flow rate 3,000l/min which considers from basic design became 0.33m/s. This paper could be applied to the design of the linear piston pump for the fish transferring.

  • PDF